318 source-backed listings mapped to this modality. Use each profile to verify FDA file number, workflow fit, integration, deployment, and unknown fields.
Turn this list into an evaluation
Each entry is an FDA submission, not a distinct commercial offer. Inspect the exact record before comparing evidence, asking for a quote or planning an integration.
Which acquisition protocols and input series match the exact labeled scope?
Is the proposed job detection, reading support, quantification, processing or another role?
How will outputs reach the reader, and who will test the installed configuration?
Authorized purpose: Auto-Seg and Spine Auto-Seg accept spine and pelvis CT images and provide three-dimensional segmentation and labels to support spine-surgery planning and assessment by spine surgeons.
Authorized purpose: An extension for syngo.via that assists trained physicians with automated and semi-automated analysis, visualization and reporting of cardiac CT angiography volume datasets for coronary-lesion evaluation, documentation, follow-up and treatment planning.
Authorized purpose: Enhanced Boundary for PCCT is a deep-learning CT processing function for improved soft-tissue delineation in routine head examinations with or without contrast.
Authorized purpose: Passive workflow prioritization for studies with imaging patterns consistent with possible total arterial occlusion in the specified vessels; not primary diagnosis, screening, disease detection, or patient-management decision support
Modality
CT/CTA
Anatomy
Aorta and lower-extremity arteries: common iliac, external iliac, common femoral, superficial femoral, and popliteal arteries
Authorized purpose: Acorn 3D Software and Acorn 3DP Model process CT, synthetic CT, and CT angiography for segmentation, visualization, measurement, treatment planning, and three-dimensional printing, including adult and pediatric spine trajectory planning.
Modality
CT/CTA
Anatomy
Spine; craniomaxillofacial; musculoskeletal anatomy; and patient-specific printed models
Authorized purpose: Concurrent-reader aid for a radiologist detecting pulmonary nodules during review of chest CT examinations in the lung cancer screening population under screening protocols.
Authorized purpose: Canon Aquilion ONE V2.0 acquires and processes whole-body CT volumes, including head, chest, abdomen, pelvis, cardiac, extremity, inner-ear, and multi-energy examinations with the labeled reconstruction functions.
Authorized purpose: Notification-only triage of adult non-contrast head CT for suspected intracranial hemorrhage and large-vessel occlusion, with parallel communication to trained clinicians during standard care.
Modality
CT/CTA
Anatomy
Brain and intracranial vessels: intracranial hemorrhage and LVO involving ICA, MCA-M1, and MCA-M2
Authorized purpose: True Definition DL is a deep-learning CT reconstruction function that enhances high-contrast spatial resolution for bone and lung imaging on compatible CT systems.
Authorized purpose: Photonova Spectra and Spectra Select are silicon-based spectral photon-counting detector CT systems that acquire cross-sectional body images, multienergy data, monochromatic images, and material-density maps for labeled head, whole-body, cardiac, vascular, and lung workflows.
Authorized purpose: DAFS automatically segments anatomy on DICOM Part 10 CT images and supports reviewed two- and three-dimensional visualization, editing, and area, volume, and intensity measurements; it does not provide diagnostic interpretation.
Authorized purpose: AV Cardiac CT assists radiologists, cardiologists and 3D technologists with viewing, processing and analysis of gated cardiac CT data, including coronary anatomy and cardiac function, to prepare cardiac interventions; physician review and decisions remain required.
Authorized purpose: Annalise Enterprise prioritizes and notifies trained CT clinicians of suspected acute infarct on non-contrast brain CT for adults; it is a study-level, non-localizing worklist aid and never downgrades an existing priority.
Authorized purpose: BriefCase-Triage CARE Multi-Triage CT analyzes contrast and non-contrast chest, abdomen, or chest/abdomen CT in adults or transitional adolescents aged 18 and older to flag suspected pneumothorax, pericardial effusion, large aortic aneurysm, or shoulder fracture/dislocation for hospital-network workflow triage; notifications and previews are for prioritization, not diagnosis.
Modality
CT/CTA
Anatomy
Chest and abdomen; pneumothorax, pericardial effusion, large aortic aneurysm, and shoulder fracture/dislocation
eyonis LCS is a concurrent-reading aid for radiologists that detects, localizes, and characterizes 4-30 mm solid and part-solid pulmonary nodules on low-dose chest CT images for high-risk lung cancer screening patients; it provides nodule measurements and malignancy scores and does not replace physician judgment.
Authorized purpose: Characterization and relative cancer-risk assessment of incidentally detected pulmonary nodules 6-15 mm in adults, with use as one input to follow-up and clinical decision-making under published guidelines; not lung-cancer screening
Authorized purpose: uCT 780 acquires cross-sectional whole-body CT images, including head, neck, cardiac, and vascular examinations, with labeled low-dose lung-cancer-screening use and uWS-CT-Dual Energy Analysis.
Authorized purpose: AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and liver density, bone mineral density, and muscle/fat composition; it is opportunistic decision support, not diagnostic interpretation or risk prediction.
Authorized purpose: Adjunctive alert and second-reader information for radiologists interpreting non-contrast chest CT in asymptomatic populations; the cleared nodule range is 3-20 mm.
Authorized purpose: Fibresolve analyzes lung CT in patients with pulmonary symptoms to provide an adjunct diagnostic-subtype classification for suspected interstitial lung disease and support referral to a multidisciplinary discussion.
Authorized purpose: Acorn 3D Software with Acorn 3DP Model provides modular image processing, visualization, segmentation, measurements, treatment planning, and three-dimensional models, including pedicle-screw trajectory planning for adult and pediatric thoracic and lumbar spine cases.
Modality
CT/CTA
Anatomy
Thoracic and lumbar spine, musculoskeletal, craniomaxillofacial, and vascular anatomy
Authorized purpose: AiORTA Plan analyzes cardiovascular CT angiography data to provide volumetric visualization and measurements as adjunctive information for licensed healthcare professionals; it is not intended to be the sole basis for treatment or patient management.
Authorized purpose: cvi42 Coronary Plaque supports qualified professionals with viewing, post-processing, and qualitative and quantitative evaluation of adult cardiac CT DICOM images to assess the presence and extent of coronary plaques and stenoses in CCTA for CAD or suspected CAD.
Authorized purpose: brAIn Shoulder Positioning assists preoperative planning and visualization for primary total shoulder replacement by segmenting and measuring shoulder CT anatomy and supporting manual implant planning.
Authorized purpose: SpectraWAVE X1-FFR Software segments coronary vessels and reports vessel dimensions, stenosis quantification, and pressure-drop estimates under the supervision of a cardiologist.
Authorized purpose: Quantitative support for thoracic CT interpretation and treatment planning, including emphysema burden, airway/lung segmentation, endobronchial valve assessment and estimated chronic perfusion defect.
Authorized purpose: SMART PCFD uses algorithms to support orthopedic diagnosis and surgical planning for progressive collapsing foot deformity from weight-bearing CT, including three-dimensional models, measurements, fixation devices, and osteotomy planning.
Authorized purpose: Parallel notification of suspected anterior-circulation large vessel occlusion on acute head CTA for specialist review; notification only, not diagnosis.
Modality
CT/CTA
Anatomy
Brain anterior circulation: internal carotid artery and M1 segment of the middle cerebral artery
Authorized purpose: Careverse CoronaryDoc is a web-based tool for trained medical professionals to view and analyze CCTA CT data for coronary plaques and stenosis, with coronary measurements, visualization, automated plaque and stenosis outputs, and structured reporting for physician review.
Authorized purpose: PRAEVAorta 2 assists clinical specialists, physicians, and other licensed practitioners with automatic vascular segmentation and maximum-diameter measurement on adult CT images; results require clinical assessment and physician validation when obtained by a non-physician.
Authorized purpose: SurgiTwin is a web pre-surgical knee-planning system that uses patient CT images to provide two-dimensional and three-dimensional planning information and a PDF report for adults older than 22.
Authorized purpose: Triage and notification of suspected intracranial hemorrhage or anterior-circulation LVO on acute non-contrast head CT; not primary diagnosis.
Modality
CT/CTA
Anatomy
Brain/head, including intracranial ICA and M1 for LVO and intracranial hemorrhage findings
Authorized purpose: Methinks CTA Stroke analyzes acute-setting brain CT angiography in adults over 21 with suspected stroke for suspected large-vessel occlusion in the terminal ICA, MCA-M1, or MCA-M2 and sends PACS and/or specialist notifications in parallel to standard care; previews are informational and not diagnostic.
Authorized purpose: Salix Coronary Plaque (V1.0.0) is a web-based adjunctive tool for qualified cardiologists and radiologists to quantify and characterize coronary plaque and stenosis and perform calcium scoring from adult cardiac CT DICOM images.
Authorized purpose: Revolution Vibe is a general-purpose and cardiac-optimized CT system for head, whole-body, cardiac, and vascular imaging across the labeled age range.
Authorized purpose: Rapid CTA 360 analyzes adult head CTA DICOM images to flag suspected large- and medium-vessel occlusion in specified intracranial and vertebral segments and notify trained clinicians for workflow triage; notifications are informational and not diagnostic.
Authorized purpose: Maximum axial abdominal aortic diameter measurement on CT exams that include L1-L5, as adjunctive unofficial information for physician review.
Authorized purpose: ASPECTS scoring and highlighted-region/voxel visualization to assist assessment of ischemic brain injury in known MCA/ICA occlusion within 12 hours from last known well.
Modality
CT/CTA
Anatomy
Brain ASPECTS regions in patients with known MCA or ICA occlusion
Authorized purpose: CardIQ Suite analyzes 2D or 3D cardiac CT DICOM data for visualization and measurement of cardiovascular anatomy, coronary calcium scoring, coronary review, heart-fat estimation, and treatment or follow-up support under clinician review.
Authorized purpose: Methinks NCCT Stroke analyzes adult non-contrast head CT to flag suspected intracranial hemorrhage and suspected large-vessel occlusion of the ICA, MCA-M1, or MCA-M2 for parallel workflow triage via PACS and/or notifications; previews are informational, not diagnostic, and a negative notification does not rule out LVO or replace CTA/standard care.
Authorized purpose: Viz Subdural+ labels, visualizes, and quantifies subdural collections from single-time-point non-contrast head CT, reporting collection grayscale value, total volume, widest width, and midline shift as annotated DICOM images for physician review with original CT.
Authorized purpose: SCENARIA View acquires axial, helical, dynamic, and interventional CT images of the body, including the head and whole body, supports reformats and volume rendering, and includes a low-dose lung-cancer-screening option used under established governmental or professional protocols.
Authorized purpose: Adjunctive pulmonary nodule detection and measurement, including temporal comparison, in chest CT screening of asymptomatic adults aged at least 55 years.
uCT ATLAS Astound and uCT ATLAS are whole-body CT systems for head, body, cardiac, and vascular imaging, with dual-energy analysis options and protocol-governed low-dose lung-screening use within approved programs.
Authorized purpose: uOmnispace.CT provides healthcare institutions with tools to view, manipulate, evaluate, and analyze medical CT images, including colon, lung, vessel, brain, cardiac, liver, rib, spine, dual-energy, perfusion, and cardiovascular applications described in the exact FDA submission.
Modality
CT/CTA
Anatomy
Colon, lungs and airway, vessels, brain, heart, liver, ribs, spine, and other CT regions
Authorized purpose: SpotLight and Duo produce cross-sectional images from X-ray transmission data for cardiovascular and thoracic examinations, including heart imaging with or without contrast and a low-dose lung-cancer-screening option used under established governmental or professional protocols.
Authorized purpose: AI-assisted acute-care triage and notification of suspected large-vessel occlusion on contrast-enhanced head CTA to prioritize review; not diagnosis.
Modality
CT/CTA
Anatomy
Brain/head vasculature, specifically the ICA, M1, and M2 segments
Authorized purpose: Analyzes existing CT images in DICOM format from adults aged 30 years and older to estimate average areal BMD of spinal bones and flag low bone density below a preset threshold, including opportunistic scans without a phantom; it does not replace DXA or other dedicated BMD testing.
Authorized purpose: TribusConnect provides remote viewing and manipulation of CT DICOM data for pre- and post-cardiac-intervention review, including volume rendering, heart segmentation, simulated fluoroscopy, endoluminal views, MIP, and MPR; it is an adjunct and not diagnostic on mobile devices.
Authorized purpose: V5med Lung AI provides concurrent-read adjunctive notification of suspected pulmonary nodules on chest CT; it does not replace radiologist judgment, diagnostic processes, or review of original CT series.
Authorized purpose: Salix Central is a web-based adjunctive tool for qualified professionals to view, post-process, and analyze cardiac CT DICOM images for physician-identified coronary plaque and stenosis assessment and non-contrast calcium scoring.
Authorized purpose: Vent Creativity Knee v1.0 (Hermes) assists healthcare professionals in transferring CT imaging into bone segmentation and preoperative orthopedic planning outputs, including proximal tibial and distal or posterior femoral cut-plane planning and diagnostic physical replicas.
Authorized purpose: brAIn Shoulder Positioning assists shoulder surgeons with preoperative planning and visualization for primary total shoulder replacement by segmenting shoulder CT data and allowing interactive implant positioning; it is an information tool and does not make the final surgical decision.
Authorized purpose: AVIEW provides CT values for pulmonary tissue from thoracic and cardiac CT datasets. The FDA indication describes lung, lobe, airway, fissure, nodule, and cardiac analysis, including nodule measurements, Lung-RADS support, and coronary calcium scoring, for adult patients.
Authorized purpose: Assists trained professionals with coronary-vessel, lumen, vessel-wall, plaque and stenosis visualization and measurements from CCTA; it does not replace clinical judgment.
Authorized purpose: JLK-SDH analyzes non-contrast head CT for suspected hemispheric subdural hemorrhage and sends notification to a clinician for review in parallel to standard care; PACS/mobile previews may be compressed and are non-diagnostic, while full patient evaluation and uncompressed diagnostic viewing remain required.
Authorized purpose: CaRi-Plaque is a web-based post-processing tool for trained operators and healthcare professionals that analyzes previously acquired CCTA DICOM data for coronary plaque characteristics, plaque burden, luminal stenosis, and related vessel measurements.
Authorized purpose: Brainomix 360 e-ASPECTS registers adult non-contrast brain CT, segments ASPECTS regions, and provides an editable ASPECTS score with highlighted regions and voxel contribution views to assist trained clinicians evaluating suspected ischemic stroke within 24 hours of last known well.
Authorized purpose: Parallel-workflow triage and notification of suspected incidental pulmonary embolism on contrast-enhanced images that include the lungs.
Authorized purpose: NAEOTOM Alpha.Peak, Alpha, Alpha.Pro, and Alpha.Prime are photon-counting CT systems for diagnostic cross-sectional imaging, treatment and interventional support, low-dose lung-cancer screening under approved protocols, and radiation-therapy planning.
Authorized purpose: Adjunctive opportunistic detection and quantification of aortic valve calcification during routine clinical-care chest CT review; a physician reviews the informational ROI and estimated calcium burden and decides any further action.
Authorized purpose: TeraRecon Aorta.CT (1.1.0) automatically segments the aorta and labels 22 aortic anatomical landmarks from adult contrast CTA DICOM for trained professionals' review in standard-of-care planning; it does not alter the original images or provide a diagnosis and excludes the FDA-listed device/anatomy conditions.
Authorized purpose: Rapid Neuro3D analyzes adult head-and-neck CTA DICOM from the aortic arch to the vertex, removing bone, tissue, and venous vessels to generate 3D/2D neurovascular visualizations, including MIP, volume-rendered, and CPR views of carotid and vertebral arteries for trained physicians' lesion review and planning; results are not standalone clinical decisions.
Authorized purpose: uCT 550 is a CT X-ray system that produces cross-sectional images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes, including whole-body, head, neck, cardiac, and vascular examinations.
Modality
CT/CTA
Anatomy
Whole body, head, neck, cardiac, and vascular anatomy
Authorized purpose: SpotLight and Duo produce cross-sectional images from X-ray transmission data for cardiovascular and thoracic examinations, including heart imaging with or without contrast and low-dose lung-cancer-screening protocols under established governmental or professional guidance.
Authorized purpose: ScreenDx provides adjunctive positive/negative assessment of interstitial lung findings on DICOM lung CT in patients older than 22 years to support referral for clinical assessment; it does not rule in or rule out lung fibrosis or replace standard diagnosis.
Authorized purpose: uCT 780 produces whole-body cross-sectional CT images, including head, neck, cardiac, and vascular imaging, supports protocol-governed low-dose lung cancer screening and dual-energy material visualization, and uses DELTA deep-learning reconstruction for adult head, chest, abdomen, cardiac, and vascular applications.
Authorized purpose: Brainomix 360 e-CTA analyzes adult CTA brain DICOM for vessel visualization and post-processing, including MCA vessel-density asymmetry, contrast/phase context, overlays, and MIP views, for trained clinical review; it is not for mobile diagnosis and its vessel-density asymmetry ratio is limited to the MCA region.
Authorized purpose: Aquilion ONE (TSX-308A/3) V1.5 acquires and displays cross-sectional volumes of the whole body, including the head, with the capability to image whole organs in a single rotation. The FDA material describes specialized studies with indicated software or hardware, FIRST reconstruction, AiCE noise reduction, spectral imaging, and PIQE high-resolution reconstruction for labeled applications.
Authorized purpose: Passive referral notification of chest-CT findings suggestive of radiological usual interstitial pneumonia to specialists associated with interstitial-lung-disease centers; not diagnosis.
Authorized purpose: Workflow triage and notification of suspect cases with three or more acute rib-fracture (RibFx) pathologies in adults or transitional adolescents aged 18 and older.
Authorized purpose: IRISeg receives DICOM-compliant contrast-enhanced CT images, provides manual and machine-learning-enabled image-analysis and segmentation tools, and creates an output file for a three-dimensional model used in preoperative planning and intraoperative display. The kidney CT auto-segmentation tool is indicated for adult patients with contrast-enhanced axial kidney CT images with slice thickness of 3 mm or less.
Authorized purpose: Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Authorized purpose: Prioritization and triage of non-contrast head CT cases with features suggestive of midline shift in individuals aged 18 years and older.
Authorized purpose: Notify hospital-network clinicians and neurovascular or neurosurgical specialists of suspected ICH on acute non-contrast head CT in parallel with standard-of-care interpretation; it is not a diagnostic device.
Modality
CT/CTA
Anatomy
Brain, with intracranial hemorrhage (ICH) subtypes including extradural, subdural, subarachnoid, intraparenchymal, and intraventricular hemorrhage.
Authorized purpose: Estimate the presence and quantity of coronary artery calcium in patients aged 30 years and older from non-contrast ECG-gated chest CT, with informational segmentation and quantification available to a physician for adjunctive review.
Modality
CT/CTA
Anatomy
Coronary arteries and coronary artery calcium within the heart
Authorized purpose: Notification-only parallel workflow analysis of acute brain CTA to identify suspected large-vessel occlusion in the terminal ICA or MCA-M1 and notify a neurovascular specialist for image review; the finding is not for diagnosis beyond notification.
Modality
CT/CTA
Anatomy
Brain; terminal intracranial ICA and MCA-M1 vessels
Authorized purpose: Assist hospital networks and trained radiologists with workflow triage by flagging and prioritizing non-enhanced head CT studies with suspected intracranial hemorrhage.
Authorized purpose: Assist hospital networks and appropriately trained physician specialists by flagging suspected acute cervical-spine fractures on cervical-spine CT for triage and prioritization; it is not designed to detect vertebral compression fractures.
Modality
CT/CTA
Anatomy
Cervical spine; acute cervical-spine fractures including non-displaced lines and displaced fragments
Authorized purpose: uAI Portal is a software solution for viewing, manipulating, communicating, and storing medical images and for supporting interpretation and evaluation in healthcare institutions. The FDA material describes lower-extremity vessel, head-and-neck vessel, coronary, pulmonary-artery, and aorta analysis functions for the corresponding CT angiography studies.
Modality
CT/CTA
Anatomy
Head and neck, coronary and cardiac, pulmonary arteries, lower-extremity vessels, and aorta
The Imbio PHA Software device is designed to measure the maximal diameters of the right and left ventricles of the heart, the main pulmonary artery, and the ascending aorta from a volumetric CTPA acquisition and report the RV/LV and Pa/Ao ratios. PHA analyzes cases using an artificial intelligence algorithm to identify the location and measurements of the anatomy. The PHA software provides the user with annotated images showing measurements. Its results are not intended to be used on a stand-alone basis for clinical decision-making or otherwise preclude clinical assessment of CTPA cases.
Authorized purpose: Non-invasive post-processing of routine non-gated, non-contrast CT studies containing the entire heart in adults aged 30 to 85 to evaluate coronary calcified plaque and estimate coronary calcium score and category.
Authorized purpose: Cardiac CT visualization, measurement, segmentation, tracking, labeling, and calcium scoring to support review of cardiovascular anatomy and pathology, coronary artery disease, and treatment-path decisions.
Modality
CT/CTA
Anatomy
Heart and cardiovascular structures, including coronaries, chambers, vessels, valves, and aorta
Authorized purpose: RUS processes CT images for trained professionals using organ and vessel segmentation, pneumoperitoneum estimation, measurements, paths, and two- or three-dimensional visualization to support reporting and treatment or surgical planning.
Authorized purpose: Acorn Segmentation is intended as an image-segmentation interface for transferring CT or CTA images to an output file, measuring, and treatment planning. The output can be used to fabricate Acorn 3DP Models by additive manufacturing for diagnostic musculoskeletal and craniomaxillofacial applications.
Authorized purpose: Notification-only triage for suspected acute intracranial hemorrhage on non-contrast brain CT, sharing cases with medical specialists in parallel with standard care.
Authorized purpose: Foot and ankle CT analysis for three-dimensional visualization, measurements, and preoperative surgical planning by qualified orthopaedic professionals.
Authorized purpose: Assist qualified medical professionals in assessing and evaluating cardiac function from multi-phase, multi-slice cardiovascular CT angiography images.
Authorized purpose: Parallel worklist triage for suspected vertebral compression fractures in patients aged 50 years and over within the standard-of-care bone-health setting; not a diagnostic device
Modality
CT/CTA
Anatomy
Thoracic and lumbar vertebrae T1-L5 within chest and/or abdomen CT
Authorized purpose: uOmnispace.CT is software for viewing, manipulating, evaluating, and analyzing medical images within healthcare institutions. The FDA indication lists colon visualization, dental panoramic and paraxial reconstruction, lung and airway segmentation and quantitative parameters, nodule analysis, vessel and brain-perfusion analysis, heart and coronary analysis, calcium scoring, dynamic analysis, bone-structure labeling, liver evaluation, dual-energy processing, and cardiovascular combined analysis.
Modality
CT/CTA
Anatomy
Colon, jaw, lungs, airways, brain, heart, vessels, liver, spine, ribs, and other labeled CT regions
Authorized purpose: Triage and notification of suspected intracranial hemorrhage on non-contrast head CT in adults and transitional adolescents aged 18 years and older, to assist prioritization while full images remain subject to standard-of-care interpretation.
CT 5300 acquires head and whole-body cross-sectional CT images for diagnosis in adult and pediatric patients and supports low-dose lung-cancer screening under approved protocols.
Improve contrast of 120 kVp single-energy body CT images by estimating 50 keV GSI-like images as non-quantitative adjunct information for patients of all ages; the original 120 kVp image must remain available for interpretation.
Authorized purpose: Assist hospital networks and appropriately trained medical specialists in triaging adults aged 22 years and older by flagging suspected aortic dissection or aortic intramural hematoma on chest or chest-abdomen CTA.
Preoperative shoulder-arthroplasty planning from adult CT DICOM images, including three-dimensional anatomy and implant-placement planning; it does not diagnose or recommend a surgical procedure.
Authorized purpose: The Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction System acquires and displays cross-sectional volumes of the whole body, including the head, with whole-organ imaging in a single rotation. The FDA material describes FIRST, AiCE, spectral imaging, and PIQE functions for the labeled abdomen, pelvis, chest, cardiac, lung, extremity, head, and inner-ear applications.
Authorized purpose: Provides quantitative coronary-plaque analysis using Agatston scoring, RCA/LCA segmentation, and calcium-score, gender, and age percentile risk stratification.
Authorized purpose: NAEOTOM Alpha with syngo CT VB10 provides photon-counting CT for diagnosis, treatment and interventional support, and approved low-dose lung screening; this submission explicitly does not support radiation-therapy planning.
Authorized purpose: The SOMATOM go and SOMATOM X platform CT systems with SOMARIS/10 syngo CT VB10 generate and process cross-sectional images from X-ray transmission data for trained staff to use as an aid in diagnosis, treatment and radiation therapy planning, and diagnostic or therapeutic interventions; the systems may also be used for low-dose lung cancer screening in high-risk populations.
Authorized purpose: Assist radiologists in prioritizing suspected intracranial hemorrhage, including subarachnoid hemorrhage, on non-contrast head CT through case-level worklist output; the output is informational and not diagnostic.
Modality
CT/CTA
Anatomy
Head/brain, including intracranial and subarachnoid spaces
Authorized purpose: AI-Rad Companion Pulmonary is image-processing software that provides quantitative and qualitative analysis from previously acquired CT DICOM images to support radiologists and physicians in evaluating and assessing lung disease. It segments and measures lungs, lobes, parenchyma, and solid or sub-solid nodules, identifies areas above or below specified Hounsfield-value thresholds, supports an external Lung CAD interface, associates nodules with lobes, and compares current nodules with known priors. Valid input is DICOM imaging of adult patients; the FDA summary identifies software version VA40.
Modality
CT/CTA
Anatomy
Adult lungs, lung lobes, pulmonary parenchyma, and solid or sub-solid lung nodules
Authorized purpose: CADx assistance for assessment and characterization of brain tissue abnormalities and early ischemic injury in patients with known MCA or ICA occlusion, using ASPECTS regions and scoring to evaluate extent of disease during image interpretation.
Authorized purpose: Worklist triage and notification for suspected incidental pulmonary embolism on contrast-enhanced CT acquired for another indication; not a diagnostic device
Modality
CT/CTA
Anatomy
Lung and pulmonary arterial segments containing incidental pulmonary embolism; subsegmental arteries are out of scope
Authorized purpose: Support trained physicians in visualizing and evaluating physician-identified liver lesions on multi-phase reconstructed CT, including lesion size, shape, position, and change over time; not for standalone diagnosis or patient-management decisions.
Authorized purpose: Automatically calculate linear and area-based cardiothoracic ratio from a CT study containing the heart to support clinician assessment of possible cardiomegaly; not for standalone clinical decision-making or diagnosis.
Authorized purpose: Revolution Ascend Sliding produces cross-sectional images by computer reconstruction of X-ray transmission data, including axial, cine, helical, cardiac, and gated acquisitions, with or without contrast. The FDA indication covers head, whole-body, cardiac, and vascular CT in patients of all ages and use for diagnosis and for planning, guiding, and monitoring therapy.
Authorized purpose: Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
Authorized purpose: Automatically label, visualize, and quantify segmentable brain structures on single-time-point non-contrast head CT, including intracranial hyperdensities, lateral ventricles, and midline shift; output must be reviewed with the original images by a physician.
Modality
CT/CTA
Anatomy
Brain (intracranial hyperdensities, lateral ventricles, and midline shift)
Authorized purpose: Adjunct assessment of early ischemic brain tissue injury and extent of disease in adult ischemic-stroke diagnostic imaging workup, typically within 24 hours of last known well
Fibresolve is a software-only device that receives and analyzes lung computed tomography (CT) imaging data in order to provide a diagnostic subtype classification in suspected cases of interstitial lung disease (ILD). The device supplements the standardof-care workflow by providing a qualitative, diagnostic classification output of imaging findings based on machine learning pattern recognition, in order to provide adjunctive information as part of a referral pathway to an appropriate Multidisciplinary Discussion (MDD) or as part of an MDD. Specifically, the tool is used to serve as an adjunct in the diagnosis of idiopathic pulmonary fibrosis (IPF) prior to invasive testing. The results of Fibresolve are intended to be used only by clinicians qualified in the care of lung disease, specifically in caring for patients with ILD, in conjunction with the patient's clinical history, symptoms, and other diagnostic tests, as well as the clinician's professional judgment. The input to Fibresolve is a DICOM-compliant lung CT scan. Clinical case eligibility includes the following criteria: Age > 22 years old. Pulmonary symptoms suggestive of possible ILD including IPF.
Authorized purpose: Provide predefined cardiovascular images and measurements to support pre-procedural planning for patients with aortic stenosis being considered for TAVR; cardiologists and radiologists must interpret and validate the report and make all treatment decisions.
Modality
CT/CTA
Anatomy
Cardiovascular structures (aortic root, aortic valve, sinus of Valsalva, sinotubular junction, and ascending aorta)
The Thirona LungQ software provides reproducible CT values for pulmonary tissue which is essential for providing quantitative support for diagnosis and follow up examination. The LungQ software can be used to support physician in the diagnosis and documentation of pulmonary tissues images (e.g. abnormalities) from CT thoracic datasets. Three-D segmentation and isolation of sub-compartments, volumetric analysis, density evaluations, fissure evaluation, and reporting tools are provided.
Authorized purpose: Provide quantitative perfusion information in brain tissue for suspected ischemic stroke patients using dynamic brain CT perfusion studies; medical imaging professionals use the information as additional data in the standard-of-care assessment, not as a standalone diagnostic tool.
Authorized purpose: Bonelogic 2.2 assists orthopedic healthcare professionals with diagnosis and surgical planning by semi-automatically segmenting bony structures from CT and producing foot and ankle 3D models and measurements for clinician review.
Authorized purpose: The Aquilion Serve SP (TSX-307B/1) V1.3 acquires and displays cross-sectional volumes of the whole body including the head, provides volume sets for specialized studies using indicated software or hardware, and includes AiCE deep-convolutional noise reduction for abdomen, pelvis, lung, cardiac, extremity, head, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, lung, cardiac, extremity, and inner-ear applications for AiCE
Authorized purpose: Four-category coronary artery calcification (CAC) assessment of plaques on non-cardiac-gated, non-contrast CT images that include the heart; preview images are informational and the result is not for stand-alone clinical decision-making.
Authorized purpose: Analyze non-contrast head CT images to help hospital networks and trained clinicians triage and prioritize suspected positive findings for intracranial ICA/M1 large-vessel occlusion and intracranial hemorrhage in adults in the acute setting within 24 hours of symptom onset or, when unclear, since last known well; the device is not a primary diagnostic device or rule-out device.
Modality
CT/CTA
Anatomy
Head/brain; intracranial ICA and M1 for LVO and intracranial hemorrhage
Authorized purpose: Automatic measurement of brain midline shift on non-contrast head CT in adults or transitional adolescents aged 18 years and older, including single-time-point measurement and same-patient multi-time-point comparison; not diagnostic.
Authorized purpose: Assist appropriately trained medical specialists by providing the maximum abdominal aortic axial diameter from contrast-enhanced CT exams that include the abdominal aorta in adults or transitional adolescents aged 18 years and older; evaluate normal and aneurysmal abdominal aortas, not postoperative aortas, and do not use results alone for clinical decisions.
Authorized purpose: Case-level triage and notification of suspected central pulmonary embolism on CTPA in adults or transitional adolescents aged 18 years and older, in parallel with standard-of-care interpretation.
Authorized purpose: CT and MRI image analysis, segmentation, visualization, and volumetry for adult abdominal treatment planning and follow-up, including liver surgery, living-donor, transplant, and oncologic workflows; it is not a diagnostic viewer or PACS replacement.
Authorized purpose: Triage and notification of suspected hemispheric subdural hemorrhage (SDH) on non-enhanced head CT, in parallel with standard-of-care interpretation; not diagnostic.
SpotLight and SpotLight Duo are dedicated cardiovascular and thoracic CT systems; K230370 adds optional deep-learning image reconstruction for patients older than 2 years to reduce image noise while maintaining CT number accuracy, high-contrast resolution, and diagnostic image quality.
Authorized purpose: The NeuViz 128 Multi-Slice CT Scanner System is a whole-body computed-tomography X-ray system with a continuously rotating X-ray tube and detector array that reconstructs X-ray transmission data into cross-sectional images of the body.
Authorized purpose: Case-level prioritization and passive notification for adult non-contrast head CT studies with features suggestive of acute intracranial hemorrhage (ICH); not a stand-alone diagnostic or rule-out tool.
Authorized purpose: Notification-only, parallel triage of acute-setting brain CTA studies for suspected large-vessel occlusion (LVO), communicating cases to a neurovascular specialist for review; not diagnostic.
Modality
CT/CTA
Anatomy
Brain/head vasculature, specifically terminal ICA and MCA-M1
Authorized purpose: Study-level triage and prioritization notification for suspected mass effect on non-contrast brain CT in patients aged 22 years and older; not a stand-alone decision or rule-out tool.
Authorized purpose: Aid triage and prioritization of adult patients aged 22 years or older with non-contrast brain CT studies containing features suggestive of vasogenic edema by providing study-level output to an order and imaging management system; the notification is not for standalone clinical decision-making or to rule out the finding.
Authorized purpose: The Aquilion Serve acquires and displays cross-sectional volumes of the whole body including the head, provides volume sets for specialized studies using indicated software or hardware, and includes AiCE deep-convolutional noise reduction for abdomen, pelvis, lung, cardiac, extremity, head, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, lung, cardiac, extremity, and inner-ear applications for AiCE
Authorized purpose: VisAble.IO is a CT image-processing software package for liver-ablation procedures that imports CT images from CT scanners and facility PACS, assists physicians in identifying ablation targets and planning virtual ablation-needle placement, and assists in confirming ablation zones.
Authorized purpose: Aid triage and prioritization of adult patients aged 22 years or older with non-contrast brain CT studies containing features suggestive of obstructive hydrocephalus by providing study-level output to an order and imaging management system; the notification is not for standalone clinical decision-making or to rule out the finding.
Authorized purpose: Assist hospital networks and trained radiologists in routine-care workflow triage by flagging and prioritizing adult studies with suspected unruptured saccular brain aneurysms at least 4 mm in diameter; compressed previews are informational and not for diagnostic use.
Authorized purpose: Provide notification-only parallel workflow triage of adult non-contrast brain CT studies acquired in the acute setting within 24 hours of symptom onset or since last known well when onset is unclear, notifying a specialist when intracranial hemorrhage is suspected.
Authorized purpose: Assist radiologists in detecting solid and subsolid pulmonary nodules during review of multivendor multi-detector CT examinations of the chest; the device is an adjunctive first- or second-reader tool.
Authorized purpose: Use with CT images to automatically generate anatomically focused multi-planar spine reformats, apply vertebral-body and intervertebral-disc labels, and export the results to predetermined DICOM destinations for review.
DeepCatch analyzes whole-body CT images to segment skin, bone, muscle, visceral fat, subcutaneous fat, internal organs, and central nervous system structures, then calculates volumes, proportions, and three-dimensional models for physician confirmation.
Authorized purpose: Provides non-invasive post-processing to quantify possible coronary calcifications and output Agatston score, arterial age, mass, and volume.
Authorized purpose: Enable visualization and measurement of heart and vessel structures for preprocedural planning and sizing of structural-heart interventions, including LAAO and TAVI; qualified clinicians use the results with clinical history, symptoms, other evaluations, and professional judgment, and the results do not replace implant-device instructions for final device selection or placement.
Modality
CT/CTA
Anatomy
Heart and cardiovascular vessels, including the left atrium, left atrial appendage, aortic root/ascending aorta, and left ventricle
Authorized purpose: Autoplaque is intended to provide an optimized non-invasive application to analyze coronary anatomy and pathology and aid in determining treatment paths from a set of Computed Tomography (CT) Angiographic images. Autoplaque is a workstation-based post processing application. It is a non-invasive diagnostic reading software intended for use by cardiologists and radiologists as an interactive tool for viewing and analyzing cardiac CT data for determining the presence and extent of coronary plaques and luminal stenoses. The software is not intended to replace the skill and judgment of a qualified medical practitioner and should only be used by people who have been appropriately trained in the software's functions, capabilities and limitations. Users should be aware that certain views make use of interpolated data. This is data that is created by the software based on the original data set. Interpolated data may give the appearance of healthy tissue in situations where pathology that is near or smaller than the scanning resolution may be present. Autoplaque must be installed on a suitable commercial computer platform. It is the user's responsibility to ensure the monitor quality and ambient light conditions are consistent with the clinical applications. Typical users of Autoplaque are trained medical professionals, including but not limited to radiologists, clinicians, technologists, and others.
Authorized purpose: Adjunctive opportunistic coronary-calcium estimation during routine chest CT review, providing informational segmentation and Agatston estimates for physician assessment rather than a stand-alone diagnosis.
Authorized purpose: Deep Learning Image Reconstruction is a deep-learning reconstruction method that produces cross-sectional images of the head and whole body from X-ray transmission data acquired at different angles and planes, including axial, helical or volumetric, and cardiac acquisitions for all ages. It can be used for head, whole-body, cardiac, and vascular CT applications.
Authorized purpose: Adjunctive cardiovascular review for radiologists and physicians in emergency medicine, specialty care, urgent care and general practice, including heart volume, coronary calcium volume, aortic segmentation, aortic diameter measurement and threshold-based highlighting of enlarged diameters.
Authorized purpose: Triage and prioritization of adult CTB studies suggestive of acute subdural/epidural hematoma, acute subarachnoid hemorrhage, intra-axial hemorrhage, or intraventricular hemorrhage; the findings are intended to be used together.
Authorized purpose: Automatically segments bone to optimize visualization of bone marrow in spectral body and extremity CT for review of traumatic and non-traumatic bone pathologies.
Modality
CT/CTA
Anatomy
Bone and bone marrow in body and extremity studies
Authorized purpose: The Aquilion Precision acquires and displays cross-sectional volumes of the whole body including the head, provides volume sets for specialized studies using indicated software or hardware, and includes FIRST iterative reconstruction and AiCE deep-convolutional noise reduction for the labeled abdomen, pelvis, chest, cardiac, extremity, head, lung, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, chest, cardiac, extremity, lung, and inner-ear applications
Authorized purpose: The Aquilion Serve acquires and displays cross-sectional volumes of the whole body including the head, provides volume sets for specialized studies using indicated software or hardware, and includes AiCE deep-convolutional noise reduction for abdomen, pelvis, lung, cardiac, extremity, head, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, lung, cardiac, extremity, and inner-ear applications for AiCE
Authorized purpose: Triage and notification for suspected intracranial hemorrhage and non-contrast CT large-vessel occlusion involving the ICA and MCA-M1.
Modality
CT/CTA
Anatomy
Brain/head, including ICH and ICA/MCA-M1 LVO findings.
Authorized purpose: Adjunctive detection of 3-20 mm pulmonary nodules in chest CT examinations for asymptomatic populations, including second-reader use.
Authorized purpose: Assists clinician assessment of brain abnormalities and ischemic injury by generating an automated ASPECTS score for known MCA/ICA occlusion cases.
Authorized purpose: uCT ATLAS Astound is a computed-tomography X-ray system that produces cross-sectional images of the whole body and is applicable to head, whole-body, cardiac, and vascular CT; it is also labeled for low-dose CT lung-cancer screening within approved governmental or professional-society programs, and its uWS-CT-Dual Energy Analysis package processes paired UIH CT images acquired at different tube voltages or currents to visualize material information.
Modality
CT/CTA
Anatomy
Head, whole body, cardiac, vascular, and lung-screening anatomy
Authorized purpose: Adjunctive measurement of the RV/LV ratio as a clinical metric used by medical professionals to quantify severity of right-heart strain in adults evaluated with CTPA; the annotated measurements support, but do not replace, clinical assessment.
Authorized purpose: Chest CT (with or without contrast) triage and notification for suspected three or more acute rib fractures in adults or transitional adolescents age 18 or older; notifications are non-diagnostic and clinicians review the original study.
Authorized purpose: Visualization, measurement, pre-procedural planning and sizing, and post-procedural evaluation for left atrial appendage closure (LAAC); the software is a planning and assessment aid and not a diagnostic replacement.
Modality
CT/CTA
Anatomy
Left atrial appendage and adjacent cardiac and extracardiac cardiovascular structures
Authorized purpose: AVIEW provides quantitative CT analysis of pulmonary and cardiac anatomy, including lung, lobe, airway, fissure, nodule, coronary calcium, and related measurements and reports to support physician review in adults.
Modality
CT/CTA
Anatomy
Lungs, lobes, airways, fissures, heart, coronary arteries, and pulmonary nodules
Authorized purpose: The Philips CT 3500 produces CT images of the head and body and is indicated for head, whole-body, cardiac-calcium-scoring, and vascular CT in patients of all ages; it is also labeled for low-dose CT lung-cancer screening within established governmental or professional-society program criteria.
Modality
CT/CTA
Anatomy
Head, whole body, cardiac, vascular, and lung-screening anatomy
Authorized purpose: Chest and abdominal CT triage and notification for suspected vertebral compression fractures in the standard-of-care bone-health workflow; notifications are non-diagnostic and clinicians review the original study.
Authorized purpose: CINA analyzes non-enhanced head CT and head CTA DICOM in parallel with standard interpretation to flag suspected intracranial hemorrhage and anterior-circulation large-vessel occlusion (distal ICA, MCA-M1 or proximal MCA-M2), issuing worklist and active notifications with informational previews for trained-radiologist triage; it does not diagnose or alter original images.
Authorized purpose: Notification-only parallel workflow to identify and communicate suspected large vessel occlusion on acute brain CTA to a neurovascular specialist; identification is not for diagnosis beyond notification.
Modality
CT/CTA
Anatomy
Brain, specifically the terminal internal carotid artery and MCA-M1 vessels
AI-Rad Companion (Musculoskeletal) is an image processing software that provides quantitative and qualitative analysis from previously acquired Computed Tomography DICOM images to support radiologists and physicians from emergency medicine, specialty care, urgent care, and general practice in the evaluation and assessment of musculoskeletal disease. It provides the following functionality: • Segmentation of vertebras • Labelling of vertebras • Measurements of heights in each vertebra and indication if they are critically different • Measurement of mean Hounsfield value in volume of interest within vertebra. Only DICOM images of adult patients are considered to be valid input.
Authorized purpose: Notification-only triage of adult head CTA for suspected complete large-vessel and medium-vessel occlusions; compressed previews are informational and the full study remains required for diagnosis.
Authorized purpose: BriefCase is a radiological computer-aided triage and notification software indicated for use in the analysis of CT exams with contrast (CTA and CT with contrast) that include the chest in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communicating suspected positive cases of aortic dissection (AD) pathology. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on the user's professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
Authorized purpose: Aquilion Precision TSX-304A/4 V10.10 with AiCE is a CT system for cross-sectional imaging of the labeled abdomen, pelvis, chest, cardiac, extremity, and head examinations, including the cleared FIRST and AiCE image-processing functions.
Modality
CT/CTA
Anatomy
Abdomen, pelvis, chest, cardiac structures, extremities, and head
Authorized purpose: Assist hospital networks and trained radiologists with workflow triage by flagging and communicating suspected IPH, IVH, SAH, and SDH findings in non-enhanced head CT images.
Modality
CT/CTA
Anatomy
Head/brain; suspected intraparenchymal, intraventricular, subarachnoid, and subdural intracranial hemorrhage.
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of CTPA images in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspected positive findings of Pulmonary Embolism (PE) pathologies. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected PE findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
AI-Rad Companion (Pulmonary) is image processing software that provides quantitative and qualitative analysis from previously acquired Computed Tomography DICOM images to support radiologists and physicians from emergency medicine, specialty care, urgent care, and general practice in the evaluation and assessment of disease of the lungs. It provides the following functionality: Segmentation and measurements of complete lung and lung lobes Identification of areas with lower Hounsfield values in comparison to a predefined threshold for complete lung and lung lobes Providing an interface to external Medical Device syngo.CT Lung CAD Segmentation and measurements of solid lung nodules. Dedication of found lung nodules to corresponding lung lobe. Correlation of segmented lung nodules of current scan with known priors and quantitative assessment of changes of the correlated data. Identification of areas with elevated Hounsfield values, where areas with elevated versus high opacities are distinguished. The software has been validated for data from Siemens Healthineers (filtered back projection and iterative reconstruction),GE Healthcare (filtered back projection reconstruction), and Philips (filtered back projection reconstruction).Only DI COM images of adult patients are considered to be valid input.
Customize supports adult total ankle arthroplasty planning with CT segmentation, 3D models, implant positioning and sizing, plan review, and X-ray-informed planning.
Authorized purpose: The Automated Bone Mineral Density Software Module measures bone mineral density from existing CT by averaging Hounsfield units in trabecular vertebral bone and can calculate age- and sex-referenced Z and T scores.
TrueFidelity deep-learning CT reconstruction produces selectable-strength images for supported head, whole-body, cardiac, and vascular applications on the Discovery CT750 HD family.
Authorized purpose: Notification-only parallel workflow for identifying and communicating images of patients with suspected subdural hemorrhage from non-contrast head CT to neurovascular or neurosurgical specialists; not diagnostic beyond notification.
Authorized purpose: syngo.CT Extended Functionality provides advanced visualization and processing tools for CT-acquired or reconstructed data, including labeled vessel, spectral, pulmonary, oncology, nodule, trauma, measurement, and analysis workflows under professional review.
Modality
CT/CTA
Anatomy
Vessels, lungs, nodules, oncology, trauma, and other anatomy represented in CT studies
Authorized purpose: ElucidVivo A.3 postprocesses contrast multidetector CT to visualize arterial vessels and provide semi-automatic lumen boundaries, stenosis and lumen measurements, vessel length, and related values to assist trained physicians in atherosclerosis stratification; measurements complement standard care and are not diagnoses or recommendations.
Authorized purpose: Aquilion ONE with Vitrea VSTP-001A provides whole-body CT acquisition and reconstruction with labeled FIRST, AiCE, spectral, cardiac, vascular, pulmonary, neurologic, abdominal, stone, gout, and embolization-planning applications in the associated Vitrea package.
Modality
CT/CTA
Anatomy
Whole body including head; brain, heart, lungs, liver, vessels, urinary stones, gout, and other anatomy represented in labeled CT workflows
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of head CTA images in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of M1 Large Vessel Occlusion (M1-LVO) pathologies. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
Authorized purpose: Assist hospital networks and trained radiologists with workflow triage by flagging and communicating suspected ICA or MCA-M1 large-vessel occlusion findings in head CTA images.
Modality
CT/CTA
Anatomy
Head/brain vasculature, specifically the intracranial ICA and MCA-M1 segments.
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of nonenhanced head CT images in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspected positive findings of Intracranial hemorrhage (ICH) pathologies. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notification for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
Philips Incisive CT provides head, whole-body, cardiac, and vascular CT imaging for patients of all ages and can support qualified low-dose lung screening under labeled programs and protocols.
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE) pathologies. The device is intended to be used on single energy exams only. Briefcase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended tobe used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
Authorized purpose: Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Modality
CT/CTA
Anatomy
Spine, including T1-L4 vertebrae and T11-L4 trabecular bone regions
Authorized purpose: Non-invasive CT image analysis that quantifies lung images and supports physician review of pulmonary tissue images and abnormalities.
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of head CT Angio (CTA) images. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspected positive cases of Brain Aneurysm (BA) findings above 5 mm size. BriefCase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a standalone desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
Authorized purpose: Customize supports adult shoulder arthroplasty planning with CT segmentation, three-dimensional models, implant positioning and sizing, case management, and physician approval; it is not for diagnosis, spine surgery, or implant and instrument design.
Authorized purpose: Revolution Ascend produces axial, cine, helical, cardiac, and gated CT images from X-ray transmission data with or without contrast, with post-processing and analysis for head, whole-body, cardiac, and vascular diagnosis, therapy planning, guidance, and monitoring.
Authorized purpose: syngo.CT Extended Functionality provides advanced visualization and processing of CT-acquired or reconstructed data, with labeled trauma, spectral, vascular, pulmonary, oncology, segmentation, measurement, and analysis tools that support professional diagnosis.
Modality
CT/CTA
Anatomy
Trauma, vessels, lungs, oncology, and other anatomy represented in CT or MR studies
Precise Image is an adult head-and-body CT reconstruction application for selected Philips Incisive CT protocols that uses a convolutional neural network to reduce noise and improve low-contrast detectability while preserving a familiar filtered-back-projection-like appearance; it is not indicated for pediatric patients.
Authorized purpose: AIBOLIT 3D+ processes, reviews, analyzes, communicates, and interchanges multidimensional digital images acquired from CT to support preoperative surgical planning, training, patient information, and intraoperative display; healthcare professionals retain final patient-management responsibility.
Modality
CT/CTA
Anatomy
Patient-specific anatomy represented in CT images for preoperative and intraoperative planning
Authorized purpose: Quantitative and qualitative CT analysis to support radiologists and physicians in emergency medicine, specialty care, urgent care, and general practice in evaluating and assessing lung disease.
Modality
CT/CTA
Anatomy
Lungs, lung lobes, lung lesions, and pulmonary opacity regions within the thorax.
Authorized purpose: Aquilion Exceed LB is a CT system for cross-sectional imaging of the labeled body regions and examinations described in K211828, with professional review of acquired and reconstructed images.
Modality
CT/CTA
Anatomy
Head, neck, chest, abdomen, pelvis, spine, extremities, and other CT anatomy
Authorized purpose: uCT ATLAS with uWS-CT-Dual Energy Analysis supports the labeled CT acquisition, reconstruction, and dual-energy image-analysis workflow for professional interpretation.
Automatic labeling, visualization, and quantification of segmentable brain structures from non-contrast head CT, including intracranial hyperdensities, lateral ventricles, and midline shift; single-timepoint volumes and longitudinal comparisons are provided when scans use the same scanner and protocol for the same person.
Modality
CT/CTA
Anatomy
Brain; intracranial hyperdensities, lateral ventricles, and midline shift
Authorized purpose: ClariCT.AI receives, processes, and enhances supported CT DICOM images regardless of the labeled CT manufacturer or model for professional review within the cleared workflow.
HALO is a notification only cloud-based image processing software application using artificial intelligence algorithms to analyze patient imaging data in parallel to the standard of care imaging interpretation. Its intended use is to identify suggestive imaging patterns of a pre-specified clinical condition and to directly notify an appropriate medical specialist. HALO's indication is to facilitate the evaluation of the brain vasculature on patients suspected of stroke by processing and analyzing CT angiograms of the brain acquired in an acute setting. After completion of the data analysis, HALO sends a notification if a pattern suggestive for a suspected intracranial Large Vessel Occlusion (LVO) of the anterior circulation (ICA,MI or M2) has been identified an image. The intended users of HALO are defined as medical specialists or a team of specialists that are involved in the diagnosis and care of stroke patients at emergency departments or other department where stroke patients are administered. They include physicians such as neurologists, radiologists, and/or other emergency department physicians. HALO's output should not be used for primary diagnosis or clinical decisions; the final diagnosis is always decided upon by the medical specialist. HALO is indicated for CT scanners from GE Healthcare and Philips.
Precise Position uses a ceiling-mounted color and depth camera with a convolutional neural network to assist positioning patients aged 16 years and older on Philips Incisive CT by identifying orientation, recommending surview range, and centering head, chest, abdominal, or pelvic anatomy.
Authorized purpose: Radiological computer-aided triage and notification for chest CTA suspected pulmonary embolism and chest or thoraco-abdominal CTA suspected aortic dissection, assisting hospital networks and trained radiologists with workflow prioritization in parallel with standard-of-care interpretation.
Authorized purpose: Adjunctive CAD assistance to alert radiologists to regions of interest that may otherwise be overlooked during chest MDCT review; concurrent first-reader or second-reader use is permitted, followed by full radiologist review.
Modality
CT/CTA
Anatomy
Pulmonary nodules in the thorax, including solid and subsolid (part-solid and ground-glass) nodules.
Authorized purpose: The device is indicated to acquire and display cross-sectional volumes of the whole body, including the head, with capability to image whole organs in a single rotation, including but not limited to the brain, heart, and pancreas. Volume sets may be used for specialized studies by a trained and qualified physician. FIRST is an iterative reconstruction algorithm for abdomen, pelvis, chest, cardiac, extremity, and head applications. AiCE is a deep-learning noise-reduction algorithm for abdomen, pelvis, lung, cardiac, brain, inner-ear, and extremity applications. The Spectral Imaging System acquires nearly simultaneous CT images at distinct tube voltages or currents to provide material-composition information.
Modality
CT/CTA
Anatomy
Whole body including head; whole organs including brain, heart, and pancreas; abdomen, pelvis, chest, cardiac, extremity, lung, brain, and inner-ear applications
Authorized purpose: Notification-only, parallel workflow tool for hospital networks and trained clinicians that analyzes acute non-contrast brain CT and communicates suspected intracranial hemorrhage to a neurovascular or neurosurgical specialist for review.
Authorized purpose: Tracks, assesses, and characterizes incidentally detected pulmonary nodules, with a CADx function for pulmonologists and radiologists.
Authorized purpose: MaxFOV 2 is a deep-learning CT image reconstruction method for head and whole-body axial, helical, and cine acquisitions. It extends the nominal display field of view when patient size or positioning places part of the body outside that field. Extended-field images are intended for radiation-therapy planning and may also visualize anatomy outside the field for non-therapy CT; the labeling identifies patients of all ages, especially bariatric patients.
Modality
CT/CTA
Anatomy
Head and whole body; anatomy outside the nominal display field of view
Authorized purpose: TruPlan provides CT image processing, visualization, measurements, and cardiac procedure-planning workflow support for the labeled use; exact procedure scope and outputs are release-specific.
Authorized purpose: The device is indicated to acquire and display cross-sectional volumes of the whole body, including the head. Volume sets may be used for specialized studies by a trained and qualified physician. AiCE-i is a deep-learning noise-reduction algorithm for abdomen, pelvis, lung, cardiac, extremity, head, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, lung, cardiac, extremity, head, and inner-ear applications
Authorized purpose: BriefCase analyzes supported noncontrast head CT, head CTA, noncontrast cervical-spine CT, and CTPA examinations to triage suspected intracranial hemorrhage, large-vessel occlusion, cervical-spine fracture-related findings, and pulmonary embolism-related findings for trained professional review.
Modality
CT/CTA
Anatomy
Adult head, brain, cervical spine, pulmonary arteries, and thorax
Authorized purpose: The device is indicated to acquire and display cross-sectional volumes of the whole body, including the head. Volume sets may be used for specialized studies by a trained and qualified physician. AiCE is a deep-learning noise-reduction algorithm for abdomen, pelvis, lung, extremity, head, and inner-ear applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, lung, extremity, head, and inner-ear applications
Authorized purpose: HALO analyzes contrast-enhanced brain CTA in the acute setting for suspected anterior-circulation large-vessel occlusion and provides notification support for emergency stroke specialists; the output is not a primary diagnosis.
Authorized purpose: Revolution Ascend is a diagnostic CT system for acquisition, reconstruction, display, and professional interpretation in the labeled scanner and protocol workflow.
Authorized purpose: Analyzes CT data to display head and neck vasculature and CT perfusion to generate regional blood-flow, blood-volume, mean-transit-time, and capillary-permeability images.
Authorized purpose: Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Authorized purpose: AVIEW provides CT values for pulmonary tissue from thoracic and cardiac CT datasets and supports quantitative diagnosis, follow-up evaluation, and documentation through lung, lobe, airway, and cardiac segmentation, inspiration-expiration registration, air-trapping analysis, volumetric and density evaluation, nodule characterization, and reporting.
Modality
CT/CTA
Anatomy
Lungs, lobes, airways, pulmonary nodules, and cardiac anatomy
Authorized purpose: BriefCase analyzes contrast-enhanced chest CT for suspected pulmonary embolism and notifies or prioritizes the study in the labeled hospital or cloud worklist workflow; the output is not a primary diagnosis.
Authorized purpose: Deep Recon is a data-driven deep-learning CT reconstruction method for axial, helical, and cardiac acquisitions. It is designed to generate lower-noise CT images, improve low-contrast detectability, and reduce the dose required for diagnostic CT imaging for adult head, chest, abdomen, cardiac, and vascular CT applications. It is intended for use only with uCT 760 and uCT 780.
Modality
CT/CTA
Anatomy
Adult head, chest, abdomen, cardiac, and vascular CT
Authorized purpose: Computer-assisted reading aid for radiologists detecting pulmonary nodules during review of chest CT examinations in an asymptomatic population; both lungs must be in the field of view, and the original CT series must remain available.
Authorized purpose: Adjunct evaluation of extent of early ischemic brain injury in patients with known MCA or ICA occlusion during stroke imaging interpretation within 6 hours
Authorized purpose: CINA analyzes nonenhanced head CT for suspected intracranial hemorrhage and head CTA for suspected large-vessel occlusion for computer-aided triage and notification in parallel with standard care; the output is not a primary diagnosis.
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of abdominal CT images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of Intra-abdominal free gas (IFG) pathologies. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
qER is a radiological computer aided triage and notification software indicated for use in the analysis of non-contrast head CT images. The device is intended to assist hospital networks and trained medical specialists in workflow triage by flagging the following suspected positive findings of pathologies in head CT images: intracranial hemorrhage, mass effect, midline shift and cranial fracture. qER uses an artificial intelligence algorithm to analyze images on a Stand-Alone Performance cloud-based application in parallel to the ongoing standard of care image interpretation.
Authorized purpose: syngo.CT CaScoring analyzes noncontrast standard- or low-dose cardiac CT, marks calcified coronary lesions, allocates them to the right coronary, left main, left anterior descending, or circumflex artery, and calculates artery and total Agatston-equivalent, mass, and volume scores.
Authorized purpose: Passive, prioritization-only, parallel-workflow notification for clinicians in bone-health settings to prioritize chest and abdominal CT cases suggestive of at least one vertebral compression fracture; it does not provide diagnosis or replace full evaluation.
Modality
CT/CTA
Anatomy
Vertebral bodies and spine as seen on chest and abdominal CT; suspected vertebral compression fractures
Authorized purpose: AVIEW LCS reviews and analyzes thoracic CT images to characterize lung nodules in a single study or over time, including nodule measurements and release-specific Lung-RADS decision support.
Authorized purpose: Provides a parallel triage workflow for head CT images with suspected intracranial hemorrhage and/or mass effect for radiologist prioritization.
Authorized purpose: Notification-only triage of adult noncontrast head CT for suspected intracranial hemorrhage; results do not replace diagnostic interpretation.
Authorized purpose: Analysis and visualization of liver CT data from DICOM 3.0-compliant CT scans to assess liver morphology and lesion change over time and to process, review, archive, print, and distribute liver CT studies.
Modality
CT/CTA
Anatomy
Liver, liver lobes, liver segments, liver lesions, and hepatic artery
Authorized purpose: Notification-only triage of adult noncontrast head CT for suspected intracranial hemorrhage, with specialist notification; results do not replace diagnostic interpretation.
Authorized purpose: Provides quantitative and qualitative analysis of previously acquired CT DICOM images to support radiologists and physicians in musculoskeletal-disease assessment.
Authorized purpose: Adjunctive CAD assistance to alert radiologists to potentially overlooked solid pulmonary nodules during chest MDCT review; second-reader use only after the radiologist's initial read.
Authorized purpose: Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.
Authorized purpose: The device is indicated to acquire and display cross-sectional volumes of the whole body, including the head, with capability to image whole organs in a single rotation, including but not limited to the brain, heart, and pancreas. Volume sets may be used for specialized studies by a trained and qualified physician. FIRST is an iterative reconstruction algorithm for abdomen, pelvis, chest, cardiac, extremity, and head applications. AiCE is a noise-reduction algorithm for abdomen, pelvis, lung, cardiac, brain, inner-ear, and extremity applications. Spectral imaging provides material-composition information from distinct CT energies.
Modality
CT/CTA
Anatomy
Whole body including head; whole organs including brain, heart, and pancreas; abdomen, pelvis, chest, cardiac, extremity, lung, brain, and inner-ear applications
Authorized purpose: Auto Positioning uses 3D patient-position information and the selected CT protocol to suggest scout range, orientation, table height, and collision checks before a technologist-approved first scout.
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of head CTA images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of Large Vessel Occlusion (LVO) pathologies.
Authorized purpose: syngo.CT CaScoring analyzes noncontrast cardiac CT, marks and allocates calcified coronary lesions to the right coronary, left main, left anterior descending, or circumflex artery, calculates Agatston-equivalent, mass, and volume scores, and produces a report.
Authorized purpose: Cleerly Labs provides interactive cardiac CT or CCTA analysis for the presence and extent of coronary plaque, atherosclerosis, and stenosis in coronary artery disease or suspected disease within the labeled workflow.
Authorized purpose: AI-Rad Companion Cardiovascular processes previously acquired CT DICOM studies to support quantitative and qualitative cardiovascular analysis, including heart segmentation and volume, coronary calcium, and aortic segmentation and diameter measurements.
Authorized purpose: AI-Rad Companion Pulmonary processes CT DICOM studies to support lung and lobe segmentation, measurements, density thresholds, and pulmonary-lesion segmentation, measurement, and lobe assignment.
Authorized purpose: Notification-only, parallel-workflow triage that identifies and communicates acute non-contrast brain CT studies with suspected ICH to a specialist for image review; not for diagnosis beyond notification.
Modality
CT/CTA
Anatomy
Brain, for suspected intracranial hemorrhage and/or hematoma.
Authorized purpose: Aquilion Precision V8.8 is an ultra-high-resolution whole-body CT system; its AiCE deep-convolutional reconstruction is limited in this clearance to abdomen and pelvis applications and is intended to reduce image noise and improve image quality.
Authorized purpose: ClariCT.AI assists radiologists and specialists by denoising and enhancing DICOM CT images of the head, chest, heart, and abdomen, including low-dose filtered-back-projection and iterative-reconstruction images, and transmitting processed images to a PACS workstation.
Authorized purpose: Case-level triage of adult non-contrast head CT examinations with features suggestive of intracranial hemorrhage (ICH); not a diagnostic or rule-out tool.
Authorized purpose: The device is indicated to acquire and display cross-sectional volumes of the whole body, including the head, with capability to image whole organs in a single rotation. Volume sets may be used for specialized studies by a trained and qualified physician. FIRST is an iterative reconstruction algorithm for abdomen, pelvis, chest, cardiac, extremity, and head applications. AiCE is a deep-learning noise-reduction algorithm for abdomen, pelvis, lung, and cardiac applications.
Modality
CT/CTA
Anatomy
Whole body including head; abdomen, pelvis, chest, cardiac, extremity, lung, and inner-ear applications
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of cervical spine on CT images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of linear lucencies in the cervical spine bone in patterns compatible with fractures.
The LungVision System is intended to enable users to segment previously acquired 3D CT datasets and overlay and register these 3D segmented data sets with fluoroscopic live X-ray images of the same anatomy in order to support catheter/device navigation during pulmonary procedures
Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of non-enhanced CT and CTPA images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communication of suspected positive findings of Intracranial Hemorrhage and Pulmonary Embolism pathologies. For the PE pathology, the software is only intended to be used on single-energy exams.
Authorized purpose: vascuCAP analyzes contrast multidetector CT of arterial vessels to support atherosclerosis stratification with color maps, three-dimensional views, multiplanar reformats, and measurements for physician review.
Authorized purpose: Accipiolx prioritizes adult noncontrast head CT studies for cases with acute intracranial hemorrhage by sending studies from PACS to an analysis engine and returning case-level worklist priority; it is not a standalone diagnostic or rule-out system.
Modality
CT/CTA
Anatomy
Adult head and brain; acute intracranial hemorrhage
Authorized purpose: BriefCase provides computer-assisted triage and notification for suspected intracranial hemorrhage on noncontrast head CT and or large-vessel occlusion on head CTA in parallel with standard care; it does not provide a primary diagnosis.
Authorized purpose: Provide quantitative support for physician diagnosis, follow-up examination, and documentation of pulmonary-tissue images or abnormalities from CT thoracic datasets.
Modality
CT/CTA
Anatomy
Thorax and lungs, including left and right lungs, lobes, pulmonary tissue, and fissures.
Authorized purpose: Image processing, analysis, and communication of dynamic brain CT perfusion datasets to calculate perfusion parameters for review by trained professionals.
ContaCT is a notification-only, parallel workflow tool for use by hospital networks and trained clinicians to identify and communicate images of specific patients to a specialist, 1 independent of the standard of care workflow. ContaCT uses an artificial intelligence algorithm to analyze images for findings suggestive of a pre-specified clinical condition and to notify an appropriate medical specialist of these findings in parallel to standard of care image interpretation. Identification of suspected findings is not for diagnostic use beyond notification. Specifically, the device analyzes CT angiogram images of the brain acquired in the acute setting and sends notifications to a neurovascular specialist that a suspected large vessel occlusion has been identified and recommends review of those images. Images can be previewed through a mobile application. Images that are previewed through the mobile application are compressed and are for informational purposes only and not intended for diagnostic use beyond notification. Notified clinicians are responsible for viewing non-compressed images on a diagnostic viewer and engaging in appropriate patient evaluation and relevant discussion with a treating physician before making care-related decisions or requests. ContaCT is limited to analysis of imaging data and should not be used in-lieu of full patient evaluation or relied upon to make or confirm diagnosis.
Authorized purpose: PixelShine is intended for networking, communication, processing, and enhancement of CT images in DICOM format to assist professional radiologists and specialists in reaching their own diagnosis. Processing is not effective for lesions, masses, or abnormalities smaller than 3 mm, and the device is not intended for diagnostic interpretation of mammography images.
Authorized purpose: ClearRead CT is a post-processing adjunct for detecting pulmonary nodules on chest CT in an asymptomatic population; it generates a secondary vessel-suppressed lung CT with CADe marks and region descriptors and must be reviewed with the original CT series.
Authorized purpose: Quantitative support for physician diagnosis, documentation, and follow-up examination of pulmonary tissue images and abnormalities from CT thoracic datasets
Authorized purpose: Hepatic VCAR analyzes CT liver images to assess liver morphology and liver lesions with automated liver, lobe, segment, lesion, and measurement tools that a clinician can edit and confirm.