Result destination
PACS is explicitly referenced as a result destination.
exact submission · checked 2026-09-01Confirm supported products, versions, routing behavior, and display requirements during local evaluation.
FDA-cleared profile
iSchemaView, Inc.
Rapid NCCT Stroke is a radiological computer aided triage and notification software indicated for use in the analysis of (1) nonenhanced head CT (NCCT) images. The device is intended to assist hospital networks and trained clinicians in workflow triage by flagging and communicating suspected positive findings of (1) head CT images for Intracranial Hemorrhage (ICH) and (2) NCCT large vessel occlusion (LVO) of the ICA and MCA-M1. Rapid NCCT Stroke uses an artificial intelligence algorithm to analyze images and highlight cases with detected (1) ICH or (2) NCCT LVO on the Rapid server on premise or in the cloud in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected ICH or LVO findings via PACS, email or mobile device. Notifications include compressed preview images that are meant for informational purposes only, and are not intended for diagnostic use beyond notification. The device does not alter the original medical image, and it is not intended to be used as a primary diagnostic device. The results of Rapid NCCT Stroke are intended to be used in conjunction with other patient information and based on professional judgment to assist with triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care. Rapid NCCT Stroke is for Adults only.
Clinical details
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Clinical-use display mirrors the best exact-submission purpose source because the reviewed FDA packet did not provide a more specific usable abstraction.
Intended-user text reported in the exact-submission ACR model card.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
Conservative normalization of explicit wording in an exact-submission source.
Clinical output reported in the exact-submission ACR model card.
Limitations and supported-acquisition details reported in the exact-submission ACR model card.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
Deployment mode explicitly reported in the exact-submission ACR model card; hosting region and current commercial configuration still require vendor confirmation.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
PACS is explicitly referenced as a result destination.
exact submission · checked 2026-09-01Confirm supported products, versions, routing behavior, and display requirements during local evaluation.
Cloud-based and on-premises deployment are explicitly described in the exact-submission ACR model card; hosting region, data flow, and current commercial configuration require vendor confirmation.
exact submission · checked 2026-09-01Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
ACR AI Central provides an exact-submission model card for Rapid NCCT Stroke; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-09Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.
Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K222884
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Costs and setup
These are common procurement questions; unknown values remain visible until a source supports them.
No public price or quote for the exact K222884 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact FDA and recall packets were prepared and identity matched, but no new clinical or performance claim was promoted in the conservative fallback. Existing exact-submission facts retain their original source status and applicability; candidate literature remains quarantined. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
Open the ledger for source dates, scope, and research-record updates.
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation
Scope: regulatoryIdentity, modalityContext
Scope: intendedUsers, careSetting, output, limitations, reportedSensitivity, reportedSpecificity, evidenceSummary, integration, deployment, anatomy, evidenceStudies, implementationCapabilities
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
automated sources checked
Alternatives
Aidoc Medical, Ltd.
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of nonenhanced head CT images in adults or transitional adolescents...
Infervision Medical Technology Co., Ltd.
InferRead CT Stroke.AI is a radiological computer aided triage and notification software for use in the analysis of Non-Enhanced Head CT images. The device is intended to assist...
AVICENNA.AI
CINA analyzes nonenhanced head CT for suspected intracranial hemorrhage and head CTA for suspected large-vessel occlusion for computer-aided triage and notification in parallel...
Methinks Software S.L.
Methinks CTA Stroke analyzes acute-setting brain CT angiography in adults over 21 with suspected stroke for suspected large-vessel occlusion in the terminal ICA, MCA-M1, or MCA-M2...