FDA-cleared profile

AVIEW

Coreline Soft Co.,Ltd.

AVIEW provides quantitative CT analysis of pulmonary and cardiac anatomy, including lung, lobe, airway, fissure, nodule, coronary calcium, and related measurements and reports to support physician review in adults.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
AVIEW provides quantitative CT analysis of pulmonary and cardiac anatomy, including lung, lobe, airway, fissure, nodule, coronary calcium, and related measurements and reports to support physician review in adults.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Intended users
Trained radiologists and qualified physicians.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Care setting and population
Thoracic and cardiac CT interpretation workflows.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Workflow role
CT segmentation, measurement, quantitative analysis, and reporting support.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Required input
Supported adult thoracic or cardiac CT DICOM studies and labeled reconstruction kernels.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Output and human action
Segmentations, density values, measurements, scores, overlays, and reports.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Limitations
The labeled use is for adults and supported thoracic or cardiac CT; scan kernel, protocol, device, image quality, and downstream clinical-review limits apply.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K214036
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
CT/CTA
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Anatomy
Lungs, lobes, airways, fissures, heart, coronary arteries, and pulmonary nodules
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2022-12-23
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
The FDA package describes DICOM 3.0 storage, transfer, query, and display for CT studies.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

This is the interface boundary described in the exact FDA package; current local compatibility, routing, identity, archive, and downtime behavior still require acceptance testing.

Deployment and data flow
The FDA package describes on-premises, cloud, mobile, and Chrome access options; the current configured topology and service boundary remain unverified.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

This is the release-level boundary described in the exact FDA package; current hosting, contracts, security, availability, upgrade path, and site configuration remain separate evidence.

Security and privacy
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only trained radiologists and qualified physicians should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Monitoring and change control
Monitor K214036 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The labeled use is for adults and supported thoracic or cardiac CT; scan kernel, protocol, device, image quality, and downstream clinical-review limits apply.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Monitoring guidance is buyer-facing implementation guidance derived from the exact cleared scope; it is not a claim that the FDA package provides a live monitoring service.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K214036 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared release includes them.

Deployment boundary

The FDA package describes on-premises, cloud, mobile, and Chrome access options; the current configured topology and service boundary remain unverified.

exact submission · checked 2026-09-04

FDA-described deployment boundaries do not establish current hosting contracts, security controls, uptime, or local qualification.

Interoperability acceptance

The FDA package describes DICOM 3.0 storage, transfer, query, and display for CT studies.

exact submission · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The labeled use is for adults and supported thoracic or cardiac CT; scan kernel, protocol, device, image quality, and downstream clinical-review limits apply.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-04

No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.

Lifecycle monitoring

Monitor K214036 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The labeled use is for adults and supported thoracic or cardiac CT; scan kernel, protocol, device, image quality, and downstream clinical-review limits apply.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. thoracic CT analysis software limits remain submission-specific.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
K214036 FDA decision material describes the cleared thoracic CT analysis software, labeled use, and submission-specific verification. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation for this exact configuration.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Sensitivity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, and source if later verified.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Specificity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, and source if later verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K214036 FDA evidence package for AVIEW

  • DesignFDA 510(k) or PMA decision evidence and product verification described in the exact submission.
  • PopulationLungs, lobes, airways, fissures, heart, coronary arteries, and pulmonary nodules
  • Scopeexact submission
  • Tested versionAVIEW configuration described in K214036
  • IndependenceSponsor or vendor study

K214036

Manufacturer evidence submitted for the exact FDA decision. It is not independent clinical validation, and local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging or clinical service line and verify payer, site-of-service, coding, and coverage assumptions independently.
  • Public source
  • Not applicable
  • Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

This is not a product-specific reimbursement determination. Build a local total-cost and value model and verify payer, site-of-service, coding, and coverage assumptions independently.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K214036 by exact native submission identifier. This does not exclude product-family, later, or adverse-event information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
11Source classes checked
20Awaiting review PubMed leads
4Awaiting review trial leads
0Unreviewed FDA recall leads

Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact-name and exact-submission searches in the checked 2026-09-01 indexes returned 20 PubMed candidate records and 4 ClinicalTrials.gov candidate records for K214036; review status is candidate_review_pending. Literature and registry candidates remain quarantined unless exact submission and tested-version linkage is established. The checked recall disposition is no exact-submission recall record was promoted; ambiguous or family-only candidates are not published. Pricing, complete security architecture, contracted deployment, exact reimbursement, and local interoperability remain unverified. Automated exact-name discovery found 20 PubMed and 4 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, acr ai central product, fda decision material, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA 510(k) decision material K214036: AVIEW

    U.S. Food and Drug Administration - Published 2022-12-23 - Accessed 2026-09-04

    Scope: identity, purpose, clinicalUse, modality, anatomy, intendedUsers, careSetting, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. AVIEW model card (K214036)

    American College of Radiology - Published 2026-06-26 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, deployment, anatomy, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

Research history

  1. K214036 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

Alternatives

Related tools to compare

FDA-cleared K200714

AVIEW

Coreline Soft Co., Ltd

AVIEW provides CT values for pulmonary tissue from thoracic and cardiac CT datasets and supports quantitative diagnosis, follow-up evaluation, and documentation through lung,...

Modality
CT/CTA
Anatomy
Lungs, lobes, airways, pulmonary nodules, and cardiac anatomy
Decision
2020-08-26
FDA-cleared K252029

AI-CVD

HeartLung Corporation

AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...

Modality
CT/CTA
Anatomy
Chest, abdomen, heart, lungs, liver, aorta, pulmonary artery, bone, muscle, and fat
Decision
2025-12-19