Supported acquisition environment
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
FDA-cleared profile
Brainomix Limited
Brainomix 360 e-ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characterization of brain tissue abnormalities using CT image data. The software automatically registers images and uses an Atlas to segment and analyze ASPECTS regions. Brainomix 360 e-ASPECTS extracts image data from individual voxels in the image to provide analysis and computer analytics and relates the analysis to the atlas defined ASPECTS regions. The imaging features are then synthesized by an artificial intelligence algorithm into a single ASPECTS (Alberta Stroke Program Early CT) Score. Brainomix 360 e-ASPECTS is indicated for evaluation of patients presenting for diagnostic imaging workup with known MCA or ICA occlusion, for evaluation of extent of disease. Extent of disease refers to the number of ASPECTS regions affected which is reflected in the total score. Brainomix 360 e-ASPECTS provides information that may be useful in the characterization of ischemic brain tissue injury during image interpretation (within 6 hours from time last known well). Brainomix 360 e-ASPECTS provides a comparative analysis to the ASPECTS standard of care radiologist assessment by providing highlighted ASPECTS regions and an automated editable ASPECTS score for clinician review. Brainomix 360 e-ASPECTS additionally provides a visualization of the voxels contributing to the automated ASPECTS score and the voxels excluded from the automated ASPECTS score.
Clinical details
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Clinical-use display mirrors the best exact-submission purpose source because the reviewed FDA packet did not provide a more specific usable abstraction.
Intended-user text reported in the exact-submission ACR model card.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
Conservative normalization of explicit wording in an exact-submission source.
Clinical output reported in the exact-submission ACR model card.
Limitations and supported-acquisition details reported in the exact-submission ACR model card.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
ACR AI Central provides an exact-submission model card for Brainomix 360 e-ASPECTS; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-09Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.
Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K221564
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Costs and setup
These are common procurement questions; unknown values remain visible until a source supports them.
No public price or quote for the exact K221564 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact FDA and recall packets were prepared and identity matched, but no new clinical or performance claim was promoted in the conservative fallback. Existing exact-submission facts retain their original source status and applicability; candidate literature remains quarantined. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
Open the ledger for source dates, scope, and research-record updates.
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation
Scope: regulatoryIdentity, modalityContext
Scope: intendedUsers, careSetting, output, limitations, reportedSensitivity, reportedSpecificity, evidenceSummary, anatomy, evidenceStudies, implementationCapabilities
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
automated sources checked
Alternatives
iSchemaView
Rapid CTA 360 analyzes adult head CTA DICOM images to flag suspected large- and medium-vessel occlusion in specified intracranial and vertebral segments and notify trained...
Brainomix Limited
Brainomix 360 e-ASPECTS registers adult non-contrast brain CT, segments ASPECTS regions, and provides an editable ASPECTS score with highlighted regions and voxel contribution...
NICo-Lab B.V.
Provide quantitative perfusion information in brain tissue for suspected ischemic stroke patients using dynamic brain CT perfusion studies; medical imaging professionals use the...
iSchemaView, Inc.
Rapid NCCT Stroke is a radiological computer aided triage and notification software indicated for use in the analysis of (1) nonenhanced head CT (NCCT) images. The device is...