FDA-cleared profile

BriefCase

Aidoc Medical, Ltd. · CT/CTA · FDA-cleared (510(k))

Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE) pathologies. The device is intended to be used on single energy exams only. Briefcase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended tobe used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.

Clinical role
Analyzes contrast-enhanced chest CTs and flags suspected incidental pulmonary embolism on a standalone desktop application in parallel to standard-of-care interpretation; notifications carry non-diagnostic compressed previews, and the device is not intended as a diagnostic device.
Images and patients
CT/CTA · Chest/Lung
Key limitation
Keep in mind: Contrast-enhanced chest CTs (not dedicated CTPA protocol); single energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age; slice thickness 0.5 – 2.0 mm axial. All studies that are technically inadequate, including studies with motion artifacts, severe metal artifacts, or inadequate field of view.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE) pathologies. The device is intended to be used on single energy exams only. Briefcase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended tobe used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
  • Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Chest/Lung Input: Contrast-enhanced chest CTs (not dedicated CTPA protocol); single-energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age.
  • Who uses it?Intended users: Hospital networks and appropriately trained medical specialists
  • What does the software produce?Output: Pulmonary Embolism (Triage)
  • What is its most important limitation?Key limitation: Contrast-enhanced chest CTs (not dedicated CTPA protocol); single energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age; slice thickness 0.5 – 2.0 mm axial. All studies that are technically inadequate, including studies with motion artifacts, severe metal artifacts, or inadequate field of view.

Clinical takeaway. Clinical role: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE) pathologies. The device is intended to be used on single energy exams only. Briefcase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended tobe used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.

Evidence takeaway. Evidence from the reviewed source record: Aidoc conducted a retrospective, blinded, multicenter study with the BriefCase software to evaluate the software's performance in identifying contrast-enhanced chest CTs (not dedicated CTPA protocol, acquired through Philips and Toshiba scanners), containing Incidental Pulmonary Embolism in 159 cases from 3 clinical study sites (2 in the US, 1 OUS). Sensitivity was 89.7% (95% CI: 80.8%, 95.5%) and specificity was 90.1% (95% CI: 81.5%, 95.6%).

Evidence context

Evidence context not reviewed for this FDA record.

Public-label constraints

Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.

Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.

Purpose
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE) pathologies. The device is intended to be used on single energy exams only. Briefcase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended tobe used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
  • Exact FDA submission
  • Checked 2026-09-19

Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.

Workflow role
Analyzes contrast-enhanced chest CTs and flags suspected incidental pulmonary embolism on a standalone desktop application in parallel to standard-of-care interpretation; notifications carry non-diagnostic compressed previews, and the device is not intended as a diagnostic device.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "contrast-enhanced chest CTs (not dedicated CTPA protocol) in adults or transitional adolescents age 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of incidental Pulmonary Embolism (iPE)" … "BriefCase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a standalone desktop application in parallel to the ongoing standard of care image interpretation.". Read from the exact FDA decision document on 2026-11-14.

Required input
Contrast-enhanced chest CTs (not dedicated CTPA protocol); single-energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age.
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet's clinical-performance table states the subject-device input criteria.

Output and clinician action
Pulmonary Embolism (Triage)
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Care setting
Adult
  • Exact FDA submission
  • Checked 2026-09-01

Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.

Intended users
Hospital networks and appropriately trained medical specialists
  • Exact FDA submission
  • Checked 2026-09-19

The exact indication states the hospital-network and trained-specialist user scope.

Limitations
Contrast-enhanced chest CTs (not dedicated CTPA protocol); single energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age; slice thickness 0.5 – 2.0 mm axial. All studies that are technically inadequate, including studies with motion artifacts, severe metal artifacts, or inadequate field of view.
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet's comparison table states the inclusion and exclusion boundary and slice thickness.

Evidence summary
Aidoc conducted a retrospective, blinded, multicenter study with the BriefCase software to evaluate the software's performance in identifying contrast-enhanced chest CTs (not dedicated CTPA protocol, acquired through Philips and Toshiba scanners), containing Incidental Pulmonary Embolism in 159 cases from 3 clinical study sites (2 in the US, 1 OUS). Sensitivity was 89.7% (95% CI: 80.8%, 95.5%) and specificity was 90.1% (95% CI: 81.5%, 95.6%).
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet reports the iPE study population, scanner context, and exact primary endpoint metrics.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
Aidoc conducted a retrospective, blinded, multicenter study with the BriefCase software to evaluate the software's performance in identifying contrast-enhanced chest CTs (not dedicated CTPA protocol, acquired through Philips and Toshiba scanners), containing Incidental Pulmonary Embolism in 159 cases from 3 clinical study sites (2 in the US, 1 OUS). Sensitivity was 89.7% (95% CI: 80.8%, 95.5%) and specificity was 90.1% (95% CI: 81.5%, 95.6%).
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet reports the iPE study population, scanner context, and exact primary endpoint metrics.

Reported sensitivity
89.7% (95% CI: 80.8%, 95.5%)
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

Reported specificity
90.1% (95% CI: 81.5%, 95.6%)
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

BriefCase-Incidental Pulmonary Embolism Triage regulatory performance study summary

  • DesignStand-Alone Performance
  • PopulationAdult
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K213886
  • Samplen=159
  • Sites3
  • IndependenceIndependence not established

K213886

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K213886. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08
Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not verified: Pricing information is recorded but not verified against a resolving source.

Reimbursement

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Integration chain: evidence at each hop

Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.

Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner

No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.

  1. Acquisition/source

    Source context, not route validation: Contrast-enhanced chest CTs (not dedicated CTPA protocol); single-energy exams; scans performed with a 64 slice or greater number of detectors; scans performed on adults/transitional adolescents ≥ 18 years of age.

    Scope: Exact FDA submission. The exact packet's clinical-performance table states the subject-device input criteria.

    Confirm scanner/model, protocol, series completeness and both software builds.

    Field checked 2026-09-19 · FDA K213886: BriefCase

  2. Routing

    Source context, not route validation: The exact FDA package describes receiving DICOM images, use with DICOM 3.0 compliant CT scanners, PACS, and radiology workstations, and sending notifications and low-quality compressed previews to the user's desktop. Interface versions and local compatibility require confirmation.

    Scope: Exact FDA submission. Packet wording: "DICOM images are received, saved, filtered and de-identified before processing." … "Both devices are artificial intelligence algorithms incorporated software packages for use with DICOM 3.0 compliant CT scanners, PACS, and radiology workstations.". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

    Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.

    Field checked 2026-11-14 · FDA K213886: BriefCase

  3. AI processing

    Source context, not route validation: The exact FDA package describes three modules: an Aidoc Hospital Server, an Aidoc Cloud Server used for image processing, and an Aidoc Worklist Application installed on the user's desktop. Current hosting, data flow, and commercial configuration require vendor confirmation.

    Scope: Exact FDA submission. Packet wording: "The device consists of the following three modules: (1) Aidoc Hospital Server (AHS); (2) Aidoc Cloud Server (ACS); and (3) Aidoc Worklist Application that is installed on the user’s desktop" … "ACS module (image processing). - ACS module (image processing).". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

    Confirm processing location, queue ownership, exclusions and exact AI build.

    Field checked 2026-11-14 · FDA K213886: BriefCase

  4. Returned objects

    Source context, not route validation: Pulmonary Embolism (Triage)

    Scope: Exact FDA submission. Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

    Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.

    Field checked 2026-09-19 · FDA K213886: BriefCase

  5. Viewer/worklist/report

    Unresolved route: Pulmonary Embolism (Triage)

    Scope: Exact FDA submission. Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

    Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.

    Field checked 2026-09-19 · FDA K213886: BriefCase

  6. Support owner

    Unresolved route: Not established for the exact route.

    Scope: Scope not established.

    Name the local, platform and AI supplier support owners and escalation path.

Planned local route tests

No tests below have been performed or accepted.

  1. Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
  2. Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
  3. Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
  4. Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
  5. Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
  6. Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
  7. Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Deployment
The exact FDA package describes three modules: an Aidoc Hospital Server, an Aidoc Cloud Server used for image processing, and an Aidoc Worklist Application installed on the user's desktop. Current hosting, data flow, and commercial configuration require vendor confirmation.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "The device consists of the following three modules: (1) Aidoc Hospital Server (AHS); (2) Aidoc Cloud Server (ACS); and (3) Aidoc Worklist Application that is installed on the user’s desktop" … "ACS module (image processing). - ACS module (image processing).". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

Integration
The exact FDA package describes receiving DICOM images, use with DICOM 3.0 compliant CT scanners, PACS, and radiology workstations, and sending notifications and low-quality compressed previews to the user's desktop. Interface versions and local compatibility require confirmation.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "DICOM images are received, saved, filtered and de-identified before processing." … "Both devices are artificial intelligence algorithms incorporated software packages for use with DICOM 3.0 compliant CT scanners, PACS, and radiology workstations.". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

Security
Aidoc's current public Security & Privacy page says its security work is led by a CISO and security team, that it has adopted the NIST Cybersecurity Framework, and that its platform runs on AWS and Azure using EDR, encryption, SIEM and CSPM tooling. The page's list of standards and certifications did not load as readable text, so no certification is stated here.
  • Vendor-wide
  • Checked 2026-10-25

Vendor-wide marketing statement, not an independent attestation. It does not establish certificate scope or expiry, the controls of this exact release, data location, retention, identity and access, or incident-response terms for a deployed configuration. Obtain these from the vendor.

Monitoring
Aidoc's security page states that its platform runs on AWS and Azure and that customer data protection is achieved with the use of EDR, encryption, SIEM, CSPM and other technologies.
  • Vendor-wide
  • Checked 2026-10-27

Vendor statement, not an attestation. The page names Aidoc's platform generally and does not scope these capabilities to any specific product release; exact-release scope is not established. The page lists technology categories in use; it states no uptime, alerting or response-time SLAs.

Supported acquisition environment

Scanner manufacturers: All

exact submission · checked 2026-09-01

Confirm currently supported software versions, protocols, and site-specific acquisition configurations.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for BriefCase; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-08
Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K213886
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
CT/CTA
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact indication defines the modality and single-energy boundary. Controlled directory display reconciled from exact FDA wording: Contrast-enhanced chest CTs (not dedicated CTPA protocol); single-energy exams only. -> CT/CTA.

Anatomy
Chest/Lung
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The subject-device table states the anatomical region of interest as Chest. Controlled directory display reconciled from exact FDA wording: Chest -> Chest/Lung.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2022-04-26
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
28Fields reviewed
11Source classes checked
20Screened PubMed leads
6Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, vendor product page, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not verified - checked 2026-09-08 - Exact FDA submission

    No public price or quote for the exact K213886 configuration was established in this review.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Reimbursement: Not publicly available - checked 2026-09-08 - Exact FDA submission

    No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Installation timeline: Not yet reviewed
  • Training: Not verified - checked 2026-09-08 - Exact FDA submission

    Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

8 sources - 3 history items

Source ledger

  1. FDA K213886: BriefCase

    U.S. Food and Drug Administration - Published 2022-04-26 - Accessed 2026-09-19

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, purpose, output, intendedUsers, input, limitations, evidenceSummary, deployment, integration

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. BriefCase-Incidental Pulmonary Embolism Triage model card (K213886)

    American College of Radiology - Published 2026-06-26 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, limitations, reportedSensitivity, reportedSpecificity, evidenceSummary, anatomy, evidenceStudies, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K213886

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

  8. Aidoc Security & Privacy

    Aidoc Medical - Accessed 2026-10-25

    Scope: security

Research history

  1. K213886 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K222277

BriefCase

Aidoc Medical, Ltd.

Authorized purpose: BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of CTPA images in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspected positive findings of Pulmonary Embolism (PE) pathologies. Briefcase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected PE findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.

Modality
CT/CTA
Anatomy
Chest/Lung
Decision
2022-08-26
FDA-cleared K201020

BriefCase

Aidoc Medical, Ltd.

Authorized purpose: BriefCase analyzes contrast-enhanced chest CT for suspected pulmonary embolism and notifies or prioritizes the study in the labeled hospital or cloud worklist workflow; the output is not a primary diagnosis.

Modality
CT/CTA
Anatomy
Chest/Lung
Decision
2020-08-26
FDA-cleared K242919

V5med Lung AI

V5med Inc.

Authorized purpose: V5med Lung AI provides concurrent-read adjunctive notification of suspected pulmonary nodules on chest CT; it does not replace radiologist judgment, diagnostic processes, or review of original CT series.

Modality
CT/CTA
Anatomy
Chest/Lung
Decision
2025-03-27

Correct this exact record

Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.

Open existing correction destination

Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.

Accepted repository change history

No entry has been added to this scoped change history for this record. This is not proof that the record never changed.

Correction policy and limits · Public repository change history