Authorized purpose: Post-processes and measures previously acquired DICOM lumbar-spine MR images through segmentation, measurement, and report export.
Clinical role
Post-processing tool that automatically segments lumbar spine MR images and generates quantitative measurements, uploaded back to PACS for users' review; users verify or correct segmentations and measurements and make their own diagnostic or treatment decisions.
Images and patients
MRI · Lumbar spine
Key limitation
Keep in mind: Not supported for pregnancy, contrast MRI, postoperative complications, scoliosis, tumors, infections, or fractures.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: Post-processes and measures previously acquired DICOM lumbar-spine MR images through segmentation, measurement, and report export.
Which images or clinical context are in scope?Modality: MRI Anatomy or clinical context: Lumbar spine Input: T2 DICOM MRI lumbar-spine examinations in patients aged 18 years or older.
Who uses it?Intended users: Radiologists and neuro- or spine surgeons in hospitals or medical institutions.
What does the software produce?Output: Anatomical feature segmentations, quantitative measurements, DICOM Structured Report, and DOCX export for user verification and correction.
What is its most important limitation?Key limitation: Not supported for pregnancy, contrast MRI, postoperative complications, scoliosis, tumors, infections, or fractures.
Clinical takeaway. Clinical role: Post-processes and measures previously acquired DICOM lumbar-spine MR images through segmentation, measurement, and report export.
Evidence takeaway. Evidence from the reviewed source record: FDA standalone performance evidence included 200 MR studies from three US sites with ground truth from five radiologists; endpoint tables describe segmentation and measurement performance.
Evidence context
Evidence context not reviewed for this FDA record.
Public-label constraints
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Purpose
Post-processes and measures previously acquired DICOM lumbar-spine MR images through segmentation, measurement, and report export.
Exact FDA submission
Checked 2026-09-15
Clinical-use display mirrors the exact FDA-supported purpose reconciled in this remediation finding.
Post-processing tool that automatically segments lumbar spine MR images and generates quantitative measurements, uploaded back to PACS for users' review; users verify or correct segmentations and measurements and make their own diagnostic or treatment decisions.
Exact FDA submission
Checked 2026-11-14
Packet wording: "image post-processing and measurement software tool that provides quantitative spine measurements from previously-acquired DICOM lumbar spine Magnetic Resonance (MR) images for users’ review, analysis, and interpretation." … "the RAI software automatically generates and uploads back to PACS the DICOM with segmentations of regions of interest along with corresponding measurements.". Read from the exact FDA decision document on 2026-11-14.
FDA standalone performance evidence included 200 MR studies from three US sites with ground truth from five radiologists; endpoint tables describe segmentation and measurement performance.
Exact FDA submission
Checked 2026-09-15
No selective metric was promoted beyond the packet summary.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA standalone performance evidence included 200 MR studies from three US sites with ground truth from five radiologists; endpoint tables describe segmentation and measurement performance.
FDA source
Exact FDA submission
Checked 2026-09-15
No selective metric was promoted beyond the packet summary.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
RemedyLogic AI MRI Lumbar Spine Reader regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K241108
Samplen=200
Sites3
IndependenceIndependence not established
K241108
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K241108. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Acquisition/source
Source context, not route validation: T2 DICOM MRI lumbar-spine examinations in patients aged 18 years or older.
Scope: Exact FDA submission. Exact FDA input and population boundary.
Confirm scanner/model, protocol, series completeness and both software builds.
Source context, not route validation: The exact-submission ACR model card explicitly references DICOM in the described input, output, or workflow; exact interfaces, versions, and local compatibility require confirmation.
Scope: Exact FDA submission. Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Source context, not route validation: The exact FDA package describes a cloud-based machine learning analytical algorithm deployed on a GPU cloud service. Current hosting, data flow, and commercial configuration require vendor confirmation.
Scope: Exact FDA submission. Packet wording: "The RAI consists of a cloud-based machine learning (ML) analytical algorithm deployed on a GPU cloud service". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.
Confirm processing location, queue ownership, exclusions and exact AI build.
Source context, not route validation: Anatomical feature segmentations, quantitative measurements, DICOM Structured Report, and DOCX export for user verification and correction.
Scope: Exact FDA submission. FDA output description.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Unresolved route: Anatomical feature segmentations, quantitative measurements, DICOM Structured Report, and DOCX export for user verification and correction.
Scope: Exact FDA submission. FDA output description.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
Planned local route tests
No tests below have been performed or accepted.
Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.
Local implementation checklist
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
The exact FDA package describes a cloud-based machine learning analytical algorithm deployed on a GPU cloud service. Current hosting, data flow, and commercial configuration require vendor confirmation.
Exact FDA submission
Checked 2026-11-14
Packet wording: "The RAI consists of a cloud-based machine learning (ML) analytical algorithm deployed on a GPU cloud service". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.
The exact-submission ACR model card explicitly references DICOM in the described input, output, or workflow; exact interfaces, versions, and local compatibility require confirmation.
Exact FDA submission
Checked 2026-09-01
Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
ACR AI Central provides an exact-submission model card for RemedyLogic AI MRI Lumbar Spine Reader; FDA labeling remains controlling for clinical use, limitations, and performance.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
25Fields reviewed
10Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Public pricing: Not verified - checked 2026-09-09 - Exact FDA submission
No public price or quote for the exact K241108 configuration was established in this review.
Pricing model: Not yet reviewed
Setup and integration fees: Not yet reviewed
Recurring fees: Not yet reviewed
Minimum commitment: Not yet reviewed
Contract duration: Not yet reviewed
Renewal terms: Not yet reviewed
Cancellation terms: Not yet reviewed
Support and service terms: Not yet reviewed
Trial or pilot terms: Not yet reviewed
Reimbursement: Not publicly available - checked 2026-09-09 - Exact FDA submission
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Data hosting location: Not yet reviewed
Data retention: Not yet reviewed
Documented data use: Not yet reviewed
Hardware requirements: Not yet reviewed
Network requirements: Not yet reviewed
Identity and access: Not yet reviewed
Security: Not verified - checked 2026-09-09 - Exact FDA submission
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Installation timeline: Not yet reviewed
Training: Not verified - checked 2026-09-09 - Exact FDA submission
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring: Not verified - checked 2026-09-09 - Exact FDA submission
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
Authorized purpose: CoLumbo version 3 is an image post-processing and measurement tool that provides quantitative measurements of the lumbar spine from previously acquired lumbar-spine MR images.
Authorized purpose: Post-process previously acquired cervical-spine MR images to segment vertebrae and disks, calculate quantitative measurements, label out-of-range values, and export results for user review and interpretation.
Modality
MRI
Anatomy
Cervical spine: vertebrae C3-C7 and disks C2C3 through C7T1
Authorized purpose: Automatic MRI segmentation and quantitative analysis of muscle, bone, fat, and other anatomical structures to assist visualization and measurement; not direct disease diagnosis.
Modality
MRI
Anatomy
Muscles, bones, and adipose tissue across the lower extremities and upper body from neck to hips, plus other segmented structures
Authorized purpose: Semi-automatic lumbar MRI segmentation and area and distance measurements with radiologist-approved PDF report to PACS; adjunct only.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
Accepted repository change history
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.