cNerve sequences
124 sequences
- EndpointAdult nerve-scouting detection
- PopulationVenue
- Tested versionVenue release cleared in K220851
FDA-cleared profile
GE Medical Systems · Ultrasound · FDA-cleared (510(k))
Authorized purpose: Venue is a mobile point-of-care diagnostic ultrasound system for broad hospital and clinic applications; K220851 adds adult cNerve scouting support, pediatric B-line and real-time ejection-fraction use, probe checks, catheter sizing, and workflow tools.
Overview status: Source-reviewed overview
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
Clinical takeaway. Clinical role: Venue is a mobile point-of-care diagnostic ultrasound system for broad hospital and clinic applications; K220851 adds adult cNerve scouting support, pediatric B-line and real-time ejection-fraction use, probe checks, catheter sizing, and workflow tools.
Evidence takeaway. Evidence from the reviewed source record: K220851 reports independent cNerve verification on 3,776 frames from 124 sequences contributed by 44 adults aged 18-82 across the United States, Japan, and Israel. The study used prespecified sequence and frame-detection requirements and subgroup checks; no clinical study was required.
Evidence context not reviewed for this FDA record.
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
The exact packet supports imaging, measurement, display, analysis, DICOM storage/archiving, and printing; it does not state reports or the dossier's combined release-specific output list.
The exact intended-use statement names qualified and trained healthcare professionals; it does not limit the class to physicians or name point-of-care ultrasound professionals.
The direct packet establishes the cNerve timing, adult-only scope, pediatric/neonate boundary, and ECG boundary without converting the scouting statement into an additional live-guidance claim.
Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Sensitivity is not the primary applicable endpoint for this acquisition, reconstruction, segmentation, planning, guidance, or quantitative-biomarker function. Use the task-specific endpoints and tested population reported below.
Specificity is not the primary applicable endpoint for this acquisition, reconstruction, segmentation, planning, guidance, or quantitative-biomarker function. Use the task-specific endpoints and tested population reported below.
124 sequences
3776 frames
80 %
K220851
Manufacturer evidence submitted for substantial equivalence; local clinical, technical, and workflow acceptance remains necessary.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
A zero-result exact-identifier search does not prove that no recall, correction, adverse-event report, or product-family safety signal exists.
Price not public here; enter your quote
Not publicly available: Reviewed sources do not publish an exact-product procurement price with a stated offer scope.
No separate named-product payment identified in reviewed public material
Centers for Medicare & Medicaid Services · United StatesBuild a local total-cost and value model; do not infer reimbursement from FDA clearance.
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Source context, not route validation: Live ultrasound from supported linear, convex, and phased-array probes plus optional ECG gating input.
Scope: Exact FDA submission. Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Confirm scanner/model, protocol, series completeness and both software builds.
Field checked 2026-09-19 · FDA K220851: Venue
Source context, not route validation: DICOM storage, archiving, printing, wireless communication, barcode and optional RFID workflows; test worklist, patient matching, archive, probe inventory, ECG gating, and role-based access.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Field checked 2026-09-03 · FDA K220851: Venue · Venue point-of-care ultrasound family
Source context, not route validation: Mobile battery-powered ultrasound system with cleanable touch interface, articulated display, supported probes, and network options.
Scope: Exact FDA submission.
Confirm processing location, queue ownership, exclusions and exact AI build.
Field checked 2026-09-03 · FDA K220851: Venue · Venue point-of-care ultrasound family
Source context, not route validation: The Venue is a general purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals for ultrasound imaging, measurement, display and analysis of the human body and fluid. System meets DICOM requirements to support users image storage and archiving needs and allows for output to printing devices.
Scope: Exact FDA submission. The exact packet supports imaging, measurement, display, analysis, DICOM storage/archiving, and printing; it does not state reports or the dossier's combined release-specific output list.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Field checked 2026-09-19 · FDA K220851: Venue
Unresolved route: The Venue is a general purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals for ultrasound imaging, measurement, display and analysis of the human body and fluid. System meets DICOM requirements to support users image storage and archiving needs and allows for output to printing devices.
Scope: Exact FDA submission. The exact packet supports imaging, measurement, display, analysis, DICOM storage/archiving, and printing; it does not state reports or the dossier's combined release-specific output list.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Field checked 2026-09-19 · FDA K220851: Venue
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
No tests below have been performed or accepted.
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Vendor statement, not an attestation. Identity bridge: GE HealthCare's own Privacy Shield page on gehealthcare.com names GE Medical Systems LLC as a US entity of the GEHC group. Corporate program statement; portal content is credentialed; exact-release scope is not established.
Map the installed model, build, options, population, anatomy, inputs, and outputs to K220851 before acceptance.
exact submission · checked 2026-09-03Later product-family features are not evidence that this cleared release includes them.
DICOM storage, archiving, printing, wireless communication, barcode and optional RFID workflows; test worklist, patient matching, archive, probe inventory, ECG gating, and role-based access.
exact submission · checked 2026-09-03Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. cNerve supports adult nerve scouting before needle insertion and is not live interventional guidance. Pediatric B-line and real-time EF exclude neonates; ECG is for image synchronization, not monitoring or diagnosis.
exact submission · checked 2026-09-03Define stop-use, escalation, rollback, and revalidation triggers before production use.
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-03Vendor productivity claims are scenario inputs, not guaranteed local savings.
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track the limits that matter for this product: cNerve supports adult nerve scouting before needle insertion and is not live interventional guidance. Pediatric B-line and real-time EF exclude neonates; ECG is for image synchronization, not monitoring or diagnosis.
exact submission · checked 2026-09-03Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
The refreshed discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, vendor product page, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.
8 sources - 3 history items
Scope: purpose, modality, anatomy, input, evidenceSummary, intendedUsers, output, limitations, clinicalUse
Scope: regulatoryIdentity, modalityContext
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: coverage, codingContext
Scope: recallDiscovery, nativeSubmissionMatching
Scope: productFamily, workflowRole, integration, training, implementationCapabilities, currentCommercialContext
Scope: security
Regulatory record
510(k)
Research record
fda record reviewed
Editorial review
Source-reviewed editorial overlay
Alternatives
Philips Ultrasound, LLC
Authorized purpose: EPIQ and Affiniti diagnostic ultrasound systems provide the labeled abdominal, cardiac, fetal, pediatric, vascular, cephalic, gynecologic, musculoskeletal, small-organ, urologic, lung, and procedural imaging applications.
Canon Medical Systems Corporation
Authorized purpose: Aplio i900, i800, and i700 software V9.0 are mobile diagnostic ultrasound systems for multi-region imaging. K252074 adds deep-learning 3rd Harmonic Imaging for abdominal images; with specified endoscopic transducers, the Aplio i800/E3 also supports imaging of the upper gastrointestinal tract, surrounding organs, airways, tracheobronchial tree, and esophagus.
Ge Medical Systems Ultrasound and Primary Care Diagnostics
Authorized purpose: LOGIQ E10s is a general-purpose diagnostic ultrasound system supporting the labeled adult, pediatric, cardiac, vascular, abdominal, obstetric, small-organ, musculoskeletal, urologic, and procedural applications.
Ge Medical Systems Ultrasound and Primary Care Diagnostics
Authorized purpose: LOGIQ E10 is a general diagnostic ultrasound system for qualified users across fetal and obstetric, abdominal, gynecologic, pediatric, small-organ, breast, cardiac, vascular, musculoskeletal, urologic, transrectal, transvaginal, transesophageal, and intraoperative applications.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Open existing correction destinationPermission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.
Correction policy and limits · Public repository change history