Authorized purpose: Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.
Clinical role
Ultrasound acquisition, measurement, analysis, reporting, and release-specific AI assistance.
Images and patients
Ultrasound · Multi-region
Key limitation
Keep in mind: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.
Which images or clinical context are in scope?Modality: Ultrasound Anatomy or clinical context: Multi-region Input: Live or imported ultrasound data from supported probes, systems, host devices, and applications.
Who uses it?Intended users: Qualified physicians, sonographers, and other trained ultrasound professionals.
What does the software produce?Output: Ultrasound images, measurements, calculations, overlays, and reports for clinician review.
What is its most important limitation?Key limitation: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
Clinical takeaway. Clinical role: Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.
Evidence takeaway. Evidence from the reviewed source record: The exact FDA document reports non-clinical testing for acoustic output, biocompatibility, cleaning and disinfection effectiveness, and thermal, electrical, electromagnetic and mechanical safety. For the cNerve tool, a test dataset of 124 sequences and 3776 frames from 44 individuals, annotated by a single clinical expert, was assessed against acceptance criteria of at least 70% of sequences meaningfully detected and at least 80% of those successfully detected; the document does not report achieved values. Clinical studies were not required. Results are as reported in the FDA submission, not independent validation.
Evidence context
Evidence context not reviewed for this FDA record.
Public-label constraints
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Purpose
Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.
AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
The exact FDA document reports non-clinical testing for acoustic output, biocompatibility, cleaning and disinfection effectiveness, and thermal, electrical, electromagnetic and mechanical safety. For the cNerve tool, a test dataset of 124 sequences and 3776 frames from 44 individuals, annotated by a single clinical expert, was assessed against acceptance criteria of at least 70% of sequences meaningfully detected and at least 80% of those successfully detected; the document does not report achieved values. Clinical studies were not required. Results are as reported in the FDA submission, not independent validation.
Exact FDA submission
Checked 2026-11-14
Packet wording: "The proposed Venue Fit has been evaluated for acoustic output, biocompatibility, cleaning and disinfection effectiveness as well as thermal, electrical, electromagnetic, and mechanical safety" … "Test dataset included 124 sequences, and 3776 frames.". Read from the exact FDA decision document on 2026-11-14.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
The exact FDA document reports non-clinical testing for acoustic output, biocompatibility, cleaning and disinfection effectiveness, and thermal, electrical, electromagnetic and mechanical safety. For the cNerve tool, a test dataset of 124 sequences and 3776 frames from 44 individuals, annotated by a single clinical expert, was assessed against acceptance criteria of at least 70% of sequences meaningfully detected and at least 80% of those successfully detected; the document does not report achieved values. Clinical studies were not required. Results are as reported in the FDA submission, not independent validation.
FDA source
Exact FDA submission
Checked 2026-11-14
Packet wording: "The proposed Venue Fit has been evaluated for acoustic output, biocompatibility, cleaning and disinfection effectiveness as well as thermal, electrical, electromagnetic, and mechanical safety" … "Test dataset included 124 sequences, and 3776 frames.". Read from the exact FDA decision document on 2026-11-14.
Sensitivity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
Reported specificity
Not applicable
Not applicable
Not applicable
Checked 2026-09-03
Specificity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K220848 FDA performance package for Venue Fit
DesignManufacturer ultrasound hardware, software, acoustic, image-quality, DICOM, electrical-safety, EMC, usability, and interventional-guidance verification and validation submitted in K220848
PopulationAdult, pediatric, fetal, cardiac, vascular, thoracic, abdominal, small-organ, and procedural ultrasound workflows using the labeled Venue Fit probes, modes, and configurations
Scopeexact submission
Tested versionVenue Fit (K220848)
IndependenceSponsor or vendor study
K220848
Manufacturer evidence submitted for FDA clearance or approval; local clinical, technical, and workflow acceptance remains necessary.
2 unlinked candidate evidence records are retained for source review and excluded from this evidence display.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
1 exact-submission FDA recall record in the 2026-09-02 openFDA snapshot identify K220848. Affected model, version, unit, correction, and current manufacturer instructions still require local confirmation. FDA recall Z-1556-2025 is Open, Classified for Venue Fit Models: R3 (Model Number H45303VFSC, H45303VFSW), R4 (Model Number H45314VFS, H45314VFSW), Venue Fit R5 system (Model Numbers H45335VFS, H45335VFSW), R3 Surgery for China, R3 PeriOP for China, R3 Expert for China, R3 Pro for China, R3 Performance for China, R3 Intervention for China diagnostic ultrasound systems. FDA reason: The battery for certain ultrasound systems can potentially develop an internal failure which could result in smoke or fire. FDA action: An URGENT MEDICAL DEVICE CORRECTION notification letter dated 3/6/25 was sent to customers. Actions to be taken by Customer/User: You can continue to use your Venue Go and Venue Fit system after following the actions below: 1) Turn the system Off and unplug the system from the wall socket. 2) Remove the system batteries by following instructions provided in the User Manual Chapter 3. These instructions are also provided in this letter in Appendix A for Venue Go and in Appendix B for Venue Fit. 3) Check the date of manufacture of the system batteries by looking at the label on the bottom of each battery (See Figure 1). The date of manufacture is displayed as YYYY-MM for year and month of manufacture. NOTE: Venue Go has two batteries and Venue Fit has one battery 4) Calculate the age of each of the system batteries. 5) If any of the batteries are more than 2 years old: a. With the system unplugged, re-insert batteries, turn the system On and leave the system On to discharge the batteries. b. Once the battery capacity indicator shows two segments or less (See Figure 2), turn the system Off and remove the batteries per step 2. c. Dispose of batteries according to local regulations. NOTE: After battery removal, you can continue to use the system with use of AC power cord. The system is fully functional without the battery. 6) If the batteries are less than 2 years old, you may continue to use the battery until the battery reaches 2 years old, at which point, repeat instructions in step 5. Please ensure all potential users in your facility are made aware of this safety notification and the recommended actions. Please retain this document for your...
FDA source
Exact FDA submission
Checked 2026-09-04
Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.
Exact native submission match in the checked openFDA snapshot. Published as a product, system, labeling, or postmarket issue; the FDA record does not identify an AI-algorithm defect unless it says so. Confirm affected model, version, units, corrective action, and completion status locally.
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Acquisition/source
Source context, not route validation: Live or imported ultrasound data from supported probes, systems, host devices, and applications.
Scope: Exact FDA submission.
Confirm scanner/model, protocol, series completeness and both software builds.
Source context, not route validation: Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.
Scope: Product family. Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Source context, not route validation: Ultrasound hardware or software with supported probes, host devices, licensed options, and network configuration.
Scope: Product family. Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.
Confirm processing location, queue ownership, exclusions and exact AI build.
Unresolved route: Ultrasound images, measurements, calculations, overlays, and reports for clinician review.
Scope: Exact FDA submission.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
Planned local route tests
No tests below have been performed or accepted.
Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.
Local implementation checklist
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Ultrasound hardware or software with supported probes, host devices, licensed options, and network configuration.
Product family
Checked 2026-09-03
Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.
Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.
Product family
Checked 2026-09-03
Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.
GE HealthCare's Product Security Portal is described as a credentialed global portal giving customers security updates, vulnerability status and required actions for GE HealthCare products potentially impacted by critical vulnerabilities, plus historical patch views; GE HealthCare references its Cybersecurity Risk Management System and publishes a Coordinated Vulnerability Disclosure Statement for reporting vulnerabilities in GE HealthCare products.
Vendor-wide
Checked 2026-10-26
Vendor statement, not an attestation. Identity bridge: GE HealthCare's own Privacy Shield page on gehealthcare.com names GE Medical Systems LLC as a US entity of the GEHC group. Corporate program statement; portal content is credentialed; exact-release scope is not established.
Only qualified physicians, sonographers, and other trained ultrasound professionals should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
Product family
Checked 2026-09-03
Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.
Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.
product family · checked 2026-09-03
Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. Vendor statements are current product-family context; confirm the exact cleared release and installed options.
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
exact submission · checked 2026-09-03
Define stop-use, escalation, rollback, and revalidation triggers before production use.
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-03
No exact-product price was found in the reviewed public material; vendor productivity claims are scenario inputs, not guaranteed local savings.
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
product family · checked 2026-09-03
Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. Vendor statements are current product-family context; confirm the exact cleared release and installed options.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
This audit distinguishes completed source review from fields that have not yet been researched.
Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
13Source classes checked
0Screened PubMed leads
3Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 0 PubMed and 3 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 0 PubMed and 3 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. 1 FDA recall candidate was manually reviewed: 1 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 1 postmarket candidate record; 1 has been reviewed (1 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, fda decision material, vendor product page, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Public pricing: Not publicly available - checked 2026-09-03 - Exact FDA submission
No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.
Ge Medical Systems Ultrasound and Primary Care Diagnostics
Authorized purpose: LOGIQ E10s is a general-purpose diagnostic ultrasound system supporting the labeled adult, pediatric, cardiac, vascular, abdominal, obstetric, small-organ, musculoskeletal, urologic, and procedural applications.
Ge Medical Systems Ultrasound and Primary Care Diagnostics
Authorized purpose: LOGIQ E10 is a general diagnostic ultrasound system for qualified users across fetal and obstetric, abdominal, gynecologic, pediatric, small-organ, breast, cardiac, vascular, musculoskeletal, urologic, transrectal, transvaginal, transesophageal, and intraoperative applications.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
Accepted repository change history
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.