FDA-cleared profile

UNiD Spine Analyzer

MEDICREA International, Inc.

The UNiDTM Spine Analyzer is intended for assisting healthcare professionals in viewing and measuring images as well as planning orthopedic surgeries. The device allows surgeons and service providers to perform generic, as well as spine related measurements on images, and to plan surgical procedures. The device also includes tools for measuring anatomical components for placement of surgical implants. Clinical judgment and experience are required to properly use the software.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
The UNiDTM Spine Analyzer is intended for assisting healthcare professionals in viewing and measuring images as well as planning orthopedic surgeries. The device allows surgeons and service providers to perform generic, as well as spine related measurements on images, and to plan surgical procedures. The device also includes tools for measuring anatomical components for placement of surgical implants. Clinical judgment and experience are required to properly use the software.
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Clinical-use display mirrors the best exact-submission purpose source because the reviewed FDA packet did not provide a more specific usable abstraction.

Intended users
Healthcare professionals, surgeons, and service providers
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Intended-user text reported in the exact-submission ACR model card.

Care setting and population
Adult and Pediatric
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.

Workflow role
Measurement or quantification
  • Public source
  • Exact FDA submission
  • Checked 2026-08-31

Conservative normalization of explicit wording in an exact-submission source.

Required input
X-ray/Radiography images or data involving Spine; consult the FDA labeling for exact protocol, series, and quality requirements.
  • Public source
  • Exact FDA submission
  • Checked 2026-08-31

Conservative normalization of explicit wording in an exact-submission source.

Output and human action
The device outputs spine-related measurements (angle, LLordo, line, circle, pelvic, T1SPi, SVA), surgical planning simulations, predictive model outputs (Degenerative Predictive Model, Adult Predictive Model, Pediatric Predictive Model), predicted values for quantitative radiographic parameters, and implant templates for placement of surgical implants.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Clinical output reported in the exact-submission ACR model card.

Limitations
Scanner manufacturers: All
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Limitations and supported-acquisition details reported in the exact-submission ACR model card.

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K212005
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
X-ray/Radiography
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Anatomy
Spine
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Anatomy normalized from explicit exact-submission ACR model-card wording.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2022-01-12
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
  • Public source
  • Exact FDA submission
  • Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
On-premise
  • Public source
  • Exact FDA submission
  • Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-09

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-09

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-09

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

Supported acquisition environment

Scanner manufacturers: All

exact submission · checked 2026-09-01

Confirm currently supported software versions, protocols, and site-specific acquisition configurations.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for UNiD Spine Analyzer; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-09

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

No exact-version evidence summary has been curated yet.

Reported sensitivity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

Reported specificity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-09

No public price or quote for the exact K212005 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-09

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
FDA recall Z-1118-2025 names UNiD Spine Analyzer SW3002 and links K212005. The record describes software anomalies affecting optional rod-planning parameters that could produce incorrect calculations; the reviewed record is open and classified. FDA recall Z-1118-2025 affects the UNiD HUB and UNiD Spine Analyzer. Software anomalies could display incorrect calculations for four optional rod-planning or surgical parameters; the released update removed the affected parameters. FDA lists the recall as open and classified.
  • FDA source
  • Exact product version
  • Checked 2026-09-04

Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.

recall: Z-1118-2025

Open, Classified

2025-02-07

Exact product match to UNiD Adaptive Spine Intelligence. The scope is limited to the optional parameters identified in the FDA record.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
22Fields reviewed
9Source classes checked
0Awaiting review PubMed leads
0Awaiting review trial leads
0Unreviewed FDA recall leads

Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact FDA and recall packets were prepared and identity matched, but no new clinical or performance claim was promoted in the conservative fallback. Existing exact-submission facts retain their original source status and applicability; candidate literature remains quarantined. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. 1 FDA recall candidate was manually reviewed: 1 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 1 postmarket candidate record; 1 has been reviewed (1 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K212005: UNiD Spine Analyzer

    U.S. Food and Drug Administration - Published 2022-01-12 - Accessed 2026-09-09

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. UNiD Spine Analyzer model card (K212005)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, limitations, anatomy, implementationCapabilities

  4. FDA recall Z-1118-2025: UNiD" Adaptive Spine Intelligence UNiD Spine Analyzer Product Number SW3002 UDI-DI code 03613720286929 Two cloud-based software applications within UNiD Adaptive Spine Intelligence (ASI): the UNiD HUB and the UNiD Spine Analyzer. The UNiD HUB cloud-based software is a healthcare application to receive, transfer, display, store data needed for planning a spine surgery or for post-operative follow-up (patient information, X-ray image and recommendations for planning). The UNiD Spine Analyzer cloud based software is a healthcare application intended for assisting healthcare professionals in viewing and measuring images as well as planning spine surgeries.

    U.S. Food and Drug Administration - Published 2025-02-07 - Accessed 2026-09-04

    Scope: postmarketSafety, affectedProduct, recallStatus, correctiveAction

  5. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  6. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  8. FDA recall Z-1118-2025: UNiD Adaptive Spine Intelligence

    U.S. Food and Drug Administration - Accessed 2026-09-09

    Scope: postmarketSafety

Research history

  1. K212005 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

Alternatives

Related tools to compare

FDA-cleared K241593

BoneMetrics (US)

Gleamer SAS

BoneMetrics is fully automated software that assists trained radiology professionals with Cobb-angle measurement on frontal spine radiographs in patients aged four years or older...

Modality
X-ray/Radiography
Anatomy
Spine
Decision
2025-02-05
FDA-cleared K251078

AutoDensity

Eos Imaging

AutoDensity estimates L1-L4 spine bone-mineral density from EOSedge dual-energy AP radiographs for opportunistic orthopedic pre-surgical assessment; it is not a replacement for...

Modality
X-ray/Radiography
Anatomy
Spine
Decision
2025-11-14
FDA-cleared K222176

BoneView

Gleamer

BoneView 1.1-US analyzes eligible 2D radiographs as a concurrent fracture-reading aid. Limb examinations apply to patients aged 2 years and older; pelvis, hip, femur, ribs,...

Modality
X-ray/Radiography
Anatomy
Spine
Decision
2023-03-02
FDA-cleared K221632

Spine CAMP™

Medical Metrics, Inc.

Spine CMAP is a fully-automated software that analyzes X-ray images of the spine to produce reports that contain static and/or motion metrics. Spine CAMP can be used to obtain...

Modality
X-ray/Radiography
Anatomy
Spine
Decision
2022-10-18