ACR exact-submission catalog context
ACR AI Central provides an exact-submission model card for UNiD Spine Analyzer; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-09FDA-cleared profile
MEDICREA INTERNATIONAL · Radiological images; modality varies or is not specified in FDA list · FDA-cleared (510(k))
Authorized purpose: Assists healthcare professionals in viewing and measuring images and planning orthopedic surgeries, including generic and spine-related measurements, surgical planning, and implant-placement measurements.
Overview status: Source-reviewed overview
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
Clinical takeaway. Clinical role: Assists healthcare professionals in viewing and measuring images and planning orthopedic surgeries, including generic and spine-related measurements, surgical planning, and implant-placement measurements.
Evidence takeaway. Evidence from the reviewed source record: Non-clinical verification/validation compared measurements with the predicate: distance mean error 0.23 mm (SD 0.42), angle mean error 0.2 degrees (SD 0.4), wedge-tool mean error 0.25 degrees (SD 0.44), and cage-tool mean error 0.4 degrees (SD 0.5). These are measurement-error/agreement endpoints, not diagnostic sensitivity, specificity, or AUC.
Evidence context not reviewed for this FDA record.
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
This field has not been curated yet.
This field has not been curated yet.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Price not public here; enter your quote
Not verified: Pricing information is recorded but not verified against a resolving source.
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Source context, not route validation: Locally supplied images in JPEG, PNG, or GIF; the FDA packet does not specify an acquisition modality or PACS input.
Scope: Exact FDA submission.
Confirm scanner/model, protocol, series completeness and both software builds.
Field checked 2026-09-09 · FDA K170172: UNiD Spine Analyzer
Source context, not route validation: Web-based software running on PC-compatible Windows or Mac with a server; the subject-device comparison lists local image input and no PACS connectivity.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Field checked 2026-09-09 · FDA K170172: UNiD Spine Analyzer
Source context, not route validation: The exact FDA package describes UNiD Spine Analyzer as web-based software that runs on a server, with a PC-compatible computer and Windows or Mac operating system listed for the subject device. Current hosting, data flow, and commercial configuration require vendor confirmation.
Scope: Exact FDA submission. Packet wording: "UNiD Spine Analyzer is a web-based software." … "Computer PC Compatible PC Compatible Operating System Windows + MAC Windows + MAC". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.
Confirm processing location, queue ownership, exclusions and exact AI build.
Field checked 2026-11-14 · FDA K170172: UNiD Spine Analyzer
Source context, not route validation: Generic and spine measurements overlaid on images, osteotomy plans, implant templates for screws/cages/rods, and anatomical-component measurements for implant placement.
Scope: Exact FDA submission.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Field checked 2026-09-09 · FDA K170172: UNiD Spine Analyzer
Unresolved route: Generic and spine measurements overlaid on images, osteotomy plans, implant templates for screws/cages/rods, and anatomical-component measurements for implant placement.
Scope: Exact FDA submission.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Field checked 2026-09-09 · FDA K170172: UNiD Spine Analyzer
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
No tests below have been performed or accepted.
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Packet wording: "UNiD Spine Analyzer is a web-based software." … "Computer PC Compatible PC Compatible Operating System Windows + MAC Windows + MAC". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.
ACR AI Central provides an exact-submission model card for UNiD Spine Analyzer; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-09Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
No public price or quote for the exact K170172 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
7 sources - 3 history items
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, deployment
Scope: regulatoryIdentity, modalityContext
Scope: anatomy
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
fda record reviewed
Editorial review
Source-reviewed editorial overlay
Alternatives
Medicrea International
Authorized purpose: Assists healthcare professionals in viewing and measuring images and planning orthopedic surgeries, including generic and spine-related measurements, surgical planning, and implant-placement measurements.
Medicrea International S.A.S. (Medtronic)
Authorized purpose: UNiD Spine Analyzer SW3002 v5.1.0 enables healthcare professionals to view and measure images and plan orthopedic spine surgeries, including preoperative and postoperative measurements and patient-specific rod or implant planning.
Siemens Healthineers AG
Authorized purpose: Syngo Carbon Clinicals VA41 provides advanced visualization and analysis for clinical images, including OrthoMatic Spine whole-spine curve-angle measurements and TimeLens comparison of regions of interest across time points.
Medicrea International S.A.S. (Medtronic)
Authorized purpose: UNiD Spine Analyzer assists healthcare professionals in viewing and measuring images and planning orthopedic spine surgery, including preoperative and postoperative measurements, surgical-strategy simulation, and patient-specific or standard implant planning; clinical judgment and surgeon validation remain required.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Open existing correction destinationPermission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.
Correction policy and limits · Public repository change history