Authorized purpose: Provide cardiac-chamber segmentations for trained healthcare professionals reviewing adult cardiac MR to assist diagnosis or treatment planning; the physician makes final patient-management decisions.
Clinical role
Cardiac MR post-processing segmentation aid for chamber delineation and downstream review or planning.
Images and patients
MRI · Cardiac chambers: left-ventricular myocardium and chamber, and right-ventricular chamber for the Cine-ax component; left-ventricular myocardium and chamber for the De-ax component.
Key limitation
Keep in mind: Adult cardiac MR use is labeled; contrast or non-contrast DICOM cardiac MR input and the supported component-specific sequences are required. The physician remains responsible for final management decisions, and exact local sequence/interface compatibility requires confirmation.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: Provide cardiac-chamber segmentations for trained healthcare professionals reviewing adult cardiac MR to assist diagnosis or treatment planning; the physician makes final patient-management decisions.
Which images or clinical context are in scope?Modality: MRI Anatomy or clinical context: Cardiac chambers: left-ventricular myocardium and chamber, and right-ventricular chamber for the Cine-ax component; left-ventricular myocardium and chamber for the De-ax component. Input: Contrast or non-contrast DICOM-compliant cardiovascular MR images from adults. Cine-ax uses 4D multiphase GRE and De-ax uses 3D multi-slice IR single-phase data; the validation cohort used GE, Philips, and Siemens scanners with cardiac gating and breath synchronization.
Who uses it?Intended users: Trained healthcare professionals, including physicians experienced in examining and evaluating cardiovascular MR images.
What does the software produce?Output: DICOM files containing Cine-ax LV myocardium, LV chamber, and RV chamber segmentations, and De-ax LV myocardium and LV chamber segmentations, for use in DICOM-compliant viewers such as TeraRecon Intuition or PACS.
What is its most important limitation?Key limitation: Adult cardiac MR use is labeled; contrast or non-contrast DICOM cardiac MR input and the supported component-specific sequences are required. The physician remains responsible for final management decisions, and exact local sequence/interface compatibility requires confirmation.
Clinical takeaway. Clinical role: Provide cardiac-chamber segmentations for trained healthcare professionals reviewing adult cardiac MR to assist diagnosis or treatment planning; the physician makes final patient-management decisions.
Evidence takeaway. Evidence from the reviewed source record: FDA K241312 reports a retrospective validation cohort of 100 adults split into 50 Cine-ax and 50 De-ax patients, with ground truth reviewed by a board-certified radiologist. Cine-ax mean Dice scores were 0.82 (95% CI 0.81-0.83) for LV myocardium, at least 0.90 (0.89-0.91) for LV chamber, and 0.84 (0.82-0.85) for RV chamber. De-ax mean Dice scores were 0.79 (0.75-0.83) for LV myocardium and 0.88 (0.84-0.92) for LV chamber. The packet reports acceptance criteria were met across stated subgroups.
Evidence context
Evidence context not reviewed for this FDA record.
Public-label constraints
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Purpose
Provide cardiac-chamber segmentations for trained healthcare professionals reviewing adult cardiac MR to assist diagnosis or treatment planning; the physician makes final patient-management decisions.
Contrast or non-contrast DICOM-compliant cardiovascular MR images from adults. Cine-ax uses 4D multiphase GRE and De-ax uses 3D multi-slice IR single-phase data; the validation cohort used GE, Philips, and Siemens scanners with cardiac gating and breath synchronization.
DICOM files containing Cine-ax LV myocardium, LV chamber, and RV chamber segmentations, and De-ax LV myocardium and LV chamber segmentations, for use in DICOM-compliant viewers such as TeraRecon Intuition or PACS.
Adult cardiac MR use is labeled; contrast or non-contrast DICOM cardiac MR input and the supported component-specific sequences are required. The physician remains responsible for final management decisions, and exact local sequence/interface compatibility requires confirmation.
FDA K241312 reports a retrospective validation cohort of 100 adults split into 50 Cine-ax and 50 De-ax patients, with ground truth reviewed by a board-certified radiologist. Cine-ax mean Dice scores were 0.82 (95% CI 0.81-0.83) for LV myocardium, at least 0.90 (0.89-0.91) for LV chamber, and 0.84 (0.82-0.85) for RV chamber. De-ax mean Dice scores were 0.79 (0.75-0.83) for LV myocardium and 0.88 (0.84-0.92) for LV chamber. The packet reports acceptance criteria were met across stated subgroups.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA K241312 reports a retrospective validation cohort of 100 adults split into 50 Cine-ax and 50 De-ax patients, with ground truth reviewed by a board-certified radiologist. Cine-ax mean Dice scores were 0.82 (95% CI 0.81-0.83) for LV myocardium, at least 0.90 (0.89-0.91) for LV chamber, and 0.84 (0.82-0.85) for RV chamber. De-ax mean Dice scores were 0.79 (0.75-0.83) for LV myocardium and 0.88 (0.84-0.92) for LV chamber. The packet reports acceptance criteria were met across stated subgroups.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
TeraRecon Cardiac.Chambers.MR (1.0.0) regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K241312
Samplen=100
IndependenceIndependence not established
K241312
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K241312. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Acquisition/source
Source context, not route validation: Contrast or non-contrast DICOM-compliant cardiovascular MR images from adults. Cine-ax uses 4D multiphase GRE and De-ax uses 3D multi-slice IR single-phase data; the validation cohort used GE, Philips, and Siemens scanners with cardiac gating and breath synchronization.
Scope: Exact FDA submission.
Confirm scanner/model, protocol, series completeness and both software builds.
Source context, not route validation: Containerized deployment and DICOM-compliant input/output are described; output files may be used by TeraRecon Intuition, PACS, or other DICOM-compliant systems. Exact interface versions and local routing behavior are not established.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Unresolved route: Not established for the exact route.
Scope: Exact FDA submission. The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Confirm processing location, queue ownership, exclusions and exact AI build.
Field checked 2026-09-08 ·
Returned objects
Source context, not route validation: DICOM files containing Cine-ax LV myocardium, LV chamber, and RV chamber segmentations, and De-ax LV myocardium and LV chamber segmentations, for use in DICOM-compliant viewers such as TeraRecon Intuition or PACS.
Scope: Exact FDA submission.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Unresolved route: DICOM files containing Cine-ax LV myocardium, LV chamber, and RV chamber segmentations, and De-ax LV myocardium and LV chamber segmentations, for use in DICOM-compliant viewers such as TeraRecon Intuition or PACS.
Scope: Exact FDA submission.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
Planned local route tests
No tests below have been performed or accepted.
Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.
Local implementation checklist
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Containerized deployment and DICOM-compliant input/output are described; output files may be used by TeraRecon Intuition, PACS, or other DICOM-compliant systems. Exact interface versions and local routing behavior are not established.
TeraRecon announces it has been recognized as an ISO 27001:2022 certified company, maintaining an information security management system with documented processes for managing sensitive company information, HR processes, and IT systems; the announcement names TeraRecon's Intuition product and Eureka Clinical AI platform.
Vendor-wide
Checked 2026-10-27
Vendor statement; the certificate was not read (a certificate PDF is hosted on the same owning domain). Applicant name variants (TeraRecon Inc. with punctuation/case variants) are bridged via the identical distinctive name. Exact-release scope is not established.
ACR AI Central provides an exact-submission model card for TeraRecon Cardiac.Chambers.MR (1.0.0); FDA labeling remains controlling for clinical use, limitations, and performance.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Cardiac chambers: left-ventricular myocardium and chamber, and right-ventricular chamber for the Cine-ax component; left-ventricular myocardium and chamber for the De-ax component.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
22Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Public pricing: Not verified - checked 2026-09-08 - Exact FDA submission
No public price or quote for the exact K241312 configuration was established in this review.
Pricing model: Not yet reviewed
Setup and integration fees: Not yet reviewed
Recurring fees: Not yet reviewed
Minimum commitment: Not yet reviewed
Contract duration: Not yet reviewed
Renewal terms: Not yet reviewed
Cancellation terms: Not yet reviewed
Support and service terms: Not yet reviewed
Trial or pilot terms: Not yet reviewed
Reimbursement: Not publicly available - checked 2026-09-08 - Exact FDA submission
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Deployment: Not verified - checked 2026-09-08 - Exact FDA submission
The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Data hosting location: Not yet reviewed
Data retention: Not yet reviewed
Documented data use: Not yet reviewed
Hardware requirements: Not yet reviewed
Network requirements: Not yet reviewed
Identity and access: Not yet reviewed
Installation timeline: Not yet reviewed
Training: Not verified - checked 2026-09-08 - Exact FDA submission
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring: Not verified - checked 2026-09-08 - Exact FDA submission
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
Authorized purpose: Myomics assists qualified medical professionals with viewing, post-processing and qualitative/quantitative evaluation of 3T cardiovascular MR images in DICOM format, including heart and adjacent-vessel measurements; semi-automated machine-learning workflows are intended for adults and contribute to comprehensive diagnostic decision-making.
Authorized purpose: Myocardial Strain Software Application provides qualitative and quantitative evaluation of cardiovascular MR images, including two-dimensional displacement, velocity, strain, strain rate, time to peak, and torsion after a qualified user confirms the contours.
Modality
MRI
Anatomy
Heart; left ventricular myocardium and cardiovascular structures
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
Accepted repository change history
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.