FDA-cleared profile

Saige-Q

DeepHealth, Inc. · Mammography/DBT · FDA-cleared (510(k))

Authorized purpose: Provides passive worklist prioritization for compatible FFDM and DBT screening mammograms.

Clinical role
Passive notification-only triage tool that assigns each screening mammogram an AI suspicion code sent to PACS/EPR/RIS worklists for prioritization; it gives no diagnostic information beyond triage and does not replace review of images.
Images and patients
Mammography/DBT · Breast
Key limitation
Keep in mind: Passive notification only, with no diagnostic information beyond triage; not a replacement for image review or standalone decision-making and cases remain on the worklist.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: Provides passive worklist prioritization for compatible FFDM and DBT screening mammograms.
  • Which images or clinical context are in scope?Modality: Mammography/DBT Anatomy or clinical context: Breast Input: DICOM files from one FFDM or DBT screening study, compatible with specified Hologic mammography equipment.
  • Who uses it?Intended users: Interpreting radiologists.
  • What does the software produce?Output: A Saige-Q suspicion code to PACS, EPR, RIS, or workstation; suspicious studies also receive an informational compressed preview.
  • What is its most important limitation?Key limitation: Passive notification only, with no diagnostic information beyond triage; not a replacement for image review or standalone decision-making and cases remain on the worklist.

Clinical takeaway. Clinical role: Provides passive worklist prioritization for compatible FFDM and DBT screening mammograms.

Evidence takeaway. Evidence from the reviewed source record: Retrospective blinded multicenter FFDM study of 501 malignant and 832 normal cases and DBT study of 517 malignant and 1,011 normal cases reported AUC 0.966 and 0.985 respectively; no one global accuracy applies.

Evidence context

Evidence context not reviewed for this FDA record.

Public-label constraints

Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.

Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.

Purpose
Provides passive worklist prioritization for compatible FFDM and DBT screening mammograms.
  • Exact FDA submission
  • Checked 2026-09-15

Clinical-use display mirrors the exact FDA-supported purpose reconciled in this remediation finding.

Workflow role
Passive notification-only triage tool that assigns each screening mammogram an AI suspicion code sent to PACS/EPR/RIS worklists for prioritization; it gives no diagnostic information beyond triage and does not replace review of images.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "Saige-Q uses an artificial intelligence algorithm to generate a code for a given mammogram, indicative of the software’s suspicion that the mammogram contains at least one suspicious finding." … "Saige-Q makes the assigned codes available to a PACS/EPR/RIS/workstation for worklist prioritization or triage.". Read from the exact FDA decision document on 2026-11-14.

Required input
DICOM files from one FFDM or DBT screening study, compatible with specified Hologic mammography equipment.
  • Exact FDA submission
  • Checked 2026-09-15

FDA packet input and system scope.

Output and clinician action
A Saige-Q suspicion code to PACS, EPR, RIS, or workstation; suspicious studies also receive an informational compressed preview.
  • Exact FDA submission
  • Checked 2026-09-15

FDA packet output scope.

Care setting
Patients having compatible full-field digital mammography (FFDM) or digital breast tomosynthesis (DBT) screening mammograms; the FDA document does not specify a facility type.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "Saige-Q is a software workflow tool designed to aid radiologists in prioritizing exams within the standard-of-care image worklist for compatible full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) screening mammograms." … "Saige-Q takes as input a set of x-ray mammogram DICOM files from a single screening mammography study (FFDM or DBT).". Read from the exact FDA decision document on 2026-11-14.

Intended users
Interpreting radiologists.
  • Exact FDA submission
  • Checked 2026-09-15

FDA packet intended-user statement.

Limitations
Passive notification only, with no diagnostic information beyond triage; not a replacement for image review or standalone decision-making and cases remain on the worklist.
  • Exact FDA submission
  • Checked 2026-09-15

Exact FDA limitation boundary.

Evidence summary
Retrospective blinded multicenter FFDM study of 501 malignant and 832 normal cases and DBT study of 517 malignant and 1,011 normal cases reported AUC 0.966 and 0.985 respectively; no one global accuracy applies.
  • Exact FDA submission
  • Checked 2026-09-15

Submission-reported performance results.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
Retrospective blinded multicenter FFDM study of 501 malignant and 832 normal cases and DBT study of 517 malignant and 1,011 normal cases reported AUC 0.966 and 0.985 respectively; no one global accuracy applies.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-15

Submission-reported performance results.

Reported sensitivity
89.40%
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

Reported specificity
86.90%
  • Public source
  • Exact FDA submission
  • Checked 2026-09-01

Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

Saige-Q regulatory performance study summary

  • DesignStand-Alone Performance
  • PopulationPopulation described in the exact-submission ACR model card
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K203517
  • Samplen=2861
  • Sites14
  • IndependenceIndependence not established

K203517

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K203517. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-09
Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not verified: Pricing information is recorded but not verified against a resolving source.

Reimbursement

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Integration chain: evidence at each hop

Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.

Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner

No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.

  1. Acquisition/source

    Source context, not route validation: DICOM files from one FFDM or DBT screening study, compatible with specified Hologic mammography equipment.

    Scope: Exact FDA submission. FDA packet input and system scope.

    Confirm scanner/model, protocol, series completeness and both software builds.

    Field checked 2026-09-15 · FDA K203517: Saige-Q

  2. Routing

    Source context, not route validation: The exact-submission ACR model card explicitly references DICOM, PACS, and RIS in the described input, output, or workflow; exact interfaces, versions, and local compatibility require confirmation.

    Scope: Exact FDA submission. Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.

    Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.

    Field checked 2026-09-01 · Saige-Q model card (K203517)

  3. AI processing

    Source context, not route validation: The exact FDA package describes Saige-Q as software installed on a compatible host machine connected to clinical IT systems such as RIS, PACS and/or EPR, with its deployment listed as on-premise. Current hosting, data flow, and commercial configuration require vendor confirmation.

    Scope: Exact FDA submission. Packet wording: "The software should be installed on a compatible host machine that is connected to the appropriate clinical IT systems (e.g., RIS, PACS and/or EPR)" … "Deployment On-premise On-premise with cloud Different, but does". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

    Confirm processing location, queue ownership, exclusions and exact AI build.

    Field checked 2026-11-14 · FDA K203517: Saige-Q

  4. Returned objects

    Source context, not route validation: A Saige-Q suspicion code to PACS, EPR, RIS, or workstation; suspicious studies also receive an informational compressed preview.

    Scope: Exact FDA submission. FDA packet output scope.

    Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.

    Field checked 2026-09-15 · FDA K203517: Saige-Q

  5. Viewer/worklist/report

    Unresolved route: A Saige-Q suspicion code to PACS, EPR, RIS, or workstation; suspicious studies also receive an informational compressed preview.

    Scope: Exact FDA submission. FDA packet output scope.

    Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.

    Field checked 2026-09-15 · FDA K203517: Saige-Q

  6. Support owner

    Unresolved route: Not established for the exact route.

    Scope: Scope not established.

    Name the local, platform and AI supplier support owners and escalation path.

Planned local route tests

No tests below have been performed or accepted.

  1. Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
  2. Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
  3. Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
  4. Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
  5. Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
  6. Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
  7. Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Deployment
The exact FDA package describes Saige-Q as software installed on a compatible host machine connected to clinical IT systems such as RIS, PACS and/or EPR, with its deployment listed as on-premise. Current hosting, data flow, and commercial configuration require vendor confirmation.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "The software should be installed on a compatible host machine that is connected to the appropriate clinical IT systems (e.g., RIS, PACS and/or EPR)" … "Deployment On-premise On-premise with cloud Different, but does". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

Integration
The exact-submission ACR model card explicitly references DICOM, PACS, and RIS in the described input, output, or workflow; exact interfaces, versions, and local compatibility require confirmation.
  • Exact FDA submission
  • Checked 2026-09-01

Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.

Input or output interoperability

DICOM is explicitly referenced in the described input, output, or workflow.

exact submission · checked 2026-09-01

The model card does not establish every supported DICOM object, transfer method, or local interface.

Result destination

PACS and workstation are explicitly referenced as a result destination.

exact submission · checked 2026-09-01

Confirm supported products, versions, routing behavior, and display requirements during local evaluation.

Supported acquisition environment

Scanner manufacturers: All

exact submission · checked 2026-09-01

Confirm currently supported software versions, protocols, and site-specific acquisition configurations.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for Saige-Q; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-09
Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K203517
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Mammography/DBT
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-15

FDA FFDM and DBT scope normalized to catalog modality.

Anatomy
Breast
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-15

Exact FDA breast scope.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2021-04-16
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
28Fields reviewed
10Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not verified - checked 2026-09-09 - Exact FDA submission

    No public price or quote for the exact K203517 configuration was established in this review.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Reimbursement: Not publicly available - checked 2026-09-09 - Exact FDA submission

    No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Security: Not verified - checked 2026-09-09 - Exact FDA submission

    Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

  • Installation timeline: Not yet reviewed
  • Training: Not verified - checked 2026-09-09 - Exact FDA submission

    Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

  • Monitoring: Not verified - checked 2026-09-09 - Exact FDA submission

    Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

7 sources - 3 history items

Source ledger

  1. FDA K203517: Saige-Q

    U.S. Food and Drug Administration - Published 2021-04-16 - Accessed 2026-09-19

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, purpose, intendedUsers, input, output, limitations, evidenceSummary, deployment

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. Saige-Q model card (K203517)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, output, limitations, reportedSensitivity, reportedSpecificity, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K203517

    U.S. Food and Drug Administration - Accessed 2026-09-09

    Scope: postmarketSafety

Research history

  1. K203517 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K252954

MammoSightAI

Neurocareai, Inc. (Dba Savelife.Ai)

Authorized purpose: Tags screening cases as suspicious or blank to aid worklist prioritization; radiologists must review every examination and it does not mark original images.

Modality
Mammography/DBT
Anatomy
Breast
Decision
2026-05-04
FDA-cleared K252482

CogNet AI-MT+

Medcognetics, Inc.

Authorized purpose: Prioritizes suspicious screening DBT examinations for MQSA interpreting physicians; every examination remains subject to full physician review.

Modality
Mammography/DBT
Anatomy
Breast
Decision
2025-12-11
FDA-cleared K233108

VinDr-Mammo

VinBigData Joint Stock Company

The VinDr-Mammo is a passive notification for prioritization-only, a parallel- workflow software tool used by MQSA qualified interpreting physicians to prioritize patients with suspicious findings in the medical care environment. VinDr-Mammo utilizes an artificial intelligence algorithm to analyze 2D FFDM screening mammograms and flags those that are suggestive of the presence of at least one suspicious finding at the exam- level. VinDr-Mammo produces an exam-level output to a PACS/Workstation for flagging the suspicious case and allows worklist prioritization. MQSA qualified interpreting physicians are responsible for reviewing each exam on a display approved for use in mammography, according to the current standard of care. VinDr-Mammo device is limited to the categorization of exams, does not provide any diagnostic information beyond triage and prioritization, does not remove images from the interpreting physician’s worklist, and should not be used in lieu of full patient evaluation, or relied upon to make or confirm diagnosis. The VinDr-Mammo device is intended for use with complete 2D FFDM mammography exams acquired using validated FFDM systems only.

Modality
Mammography/DBT
Anatomy
Breast
Decision
2024-05-23
FDA-cleared K220080

CogNet QmTRIAGE

MedCognetics, Inc.

Authorized purpose: Passive exam-level notification and prioritization of suspicious findings in screening mammograms.

Modality
Mammography/DBT
Anatomy
Breast
Decision
2022-09-29

Correct this exact record

Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.

Open existing correction destination

Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.

Accepted repository change history

No entry has been added to this scoped change history for this record. This is not proof that the record never changed.

Correction policy and limits · Public repository change history