FDA-approved profile

RAPIDSCREEN RS-2000

RIVERAIN MEDICAL GROUP · X-ray/Radiography · FDA-approved (PMA)

Authorized purpose: RAPIDSCREEN RS-2000 is a PMA-authorized computer-aided detection device that identifies and marks regions of interest on digitized frontal chest radiographs associated with solitary pulmonary nodules 9-30 mm, as an aid after the physician's initial interpretation.

Clinical role
Computer-aided marking after the physician's initial radiograph interpretation.
Images and patients
X-ray/Radiography · Adult chest; solitary pulmonary nodules 9-30 mm
Key limitation
Keep in mind: The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: RAPIDSCREEN RS-2000 is a PMA-authorized computer-aided detection device that identifies and marks regions of interest on digitized frontal chest radiographs associated with solitary pulmonary nodules 9-30 mm, as an aid after the physician's initial interpretation.
  • Which images or clinical context are in scope?Modality: X-ray/Radiography Anatomy or clinical context: Adult chest; solitary pulmonary nodules 9-30 mm Input: Digitized frontal chest radiographs.
  • Who uses it?Intended users: Physicians and qualified radiology professionals.
  • What does the software produce?Output: Marked regions of interest associated with labeled pulmonary nodules.
  • What is its most important limitation?Key limitation: The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.

Clinical takeaway. Clinical role: RAPIDSCREEN RS-2000 is a PMA-authorized computer-aided detection device that identifies and marks regions of interest on digitized frontal chest radiographs associated with solitary pulmonary nodules 9-30 mm, as an aid after the physician's initial interpretation.

Evidence takeaway. Evidence from the reviewed source record: P000041 FDA decision material describes the cleared PMA-authorized chest-radiograph computer-aided detection device, labeled use, and submission-specific verification. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation for this exact configuration.

Evidence context

Evidence context not reviewed for this FDA record.

Public-label constraints

Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.

Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.

Purpose
RAPIDSCREEN RS-2000 is a PMA-authorized computer-aided detection device that identifies and marks regions of interest on digitized frontal chest radiographs associated with solitary pulmonary nodules 9-30 mm, as an aid after the physician's initial interpretation.
  • Exact FDA submission
  • Checked 2026-09-04
Workflow role
Computer-aided marking after the physician's initial radiograph interpretation.
  • Exact FDA submission
  • Checked 2026-09-04
Required input
Digitized frontal chest radiographs.
  • Exact FDA submission
  • Checked 2026-09-04
Output and clinician action
Marked regions of interest associated with labeled pulmonary nodules.
  • Exact FDA submission
  • Checked 2026-09-04
Care setting
Radiology workflows using digitized frontal chest radiographs.
  • Exact FDA submission
  • Checked 2026-09-04
Intended users
Physicians and qualified radiology professionals.
  • Exact FDA submission
  • Checked 2026-09-04
Limitations
The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.
  • Exact FDA submission
  • Checked 2026-09-04
Evidence summary
P000041 FDA decision material describes the cleared PMA-authorized chest-radiograph computer-aided detection device, labeled use, and submission-specific verification. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation for this exact configuration.
  • Exact FDA submission
  • Checked 2026-09-04

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
P000041 FDA decision material describes the cleared PMA-authorized chest-radiograph computer-aided detection device, labeled use, and submission-specific verification. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation for this exact configuration.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Sensitivity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, and source if later verified.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Specificity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, and source if later verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

P000041 FDA evidence package for RAPIDSCREEN RS-2000

  • DesignFDA 510(k) or PMA decision evidence and product verification described in the exact submission.
  • PopulationAdult chest; solitary pulmonary nodules 9-30 mm
  • Scopeexact submission
  • Tested versionRAPIDSCREEN RS-2000 configuration described in P000041
  • IndependenceSponsor or vendor study

P000041

Manufacturer evidence submitted for the exact FDA decision. It is not independent clinical validation, and local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to P000041 by exact native submission identifier. This does not exclude product-family, later, or adverse-event information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not publicly available: Reviewed sources do not publish an exact-product procurement price with a stated offer scope.

Reimbursement

Reimbursement
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging or clinical service line and verify payer, site-of-service, coding, and coverage assumptions independently.
  • Service-level, not product-specific
  • Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

This is not a product-specific reimbursement determination. Build a local total-cost and value model and verify payer, site-of-service, coding, and coverage assumptions independently.

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Integration chain: evidence at each hop

Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.

Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner

No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.

  1. Acquisition/source

    Source context, not route validation: Digitized frontal chest radiographs.

    Scope: Exact FDA submission.

    Confirm scanner/model, protocol, series completeness and both software builds.

    Field checked 2026-09-04 · FDA PMA decision material P000041: RAPIDSCREEN RS-2000

  2. Routing

    Unresolved route: Not established for the exact route.

    Scope: Exact FDA submission. The exact public FDA decision material does not establish a complete integration contract. Confirm DICOM, worklist, identity, interfaces, exports, routing, audit behavior, and downtime locally.

    Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.

    Field checked 2026-09-04 ·

  3. AI processing

    Unresolved route: Not established for the exact route.

    Scope: Exact FDA submission. The exact public FDA decision material does not establish the complete deployment topology, hosting responsibility, availability, upgrade path, or service contract.

    Confirm processing location, queue ownership, exclusions and exact AI build.

    Field checked 2026-09-04 ·

  4. Returned objects

    Source context, not route validation: Marked regions of interest associated with labeled pulmonary nodules.

    Scope: Exact FDA submission.

    Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.

    Field checked 2026-09-04 · FDA PMA decision material P000041: RAPIDSCREEN RS-2000

  5. Viewer/worklist/report

    Unresolved route: Marked regions of interest associated with labeled pulmonary nodules.

    Scope: Exact FDA submission.

    Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.

    Field checked 2026-09-04 · FDA PMA decision material P000041: RAPIDSCREEN RS-2000

  6. Support owner

    Unresolved route: Not established for the exact route.

    Scope: Scope not established.

    Name the local, platform and AI supplier support owners and escalation path.

Planned local route tests

No tests below have been performed or accepted.

  1. Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
  2. Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
  3. Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
  4. Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
  5. Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
  6. Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
  7. Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Training
Only physicians and qualified radiology professionals should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • Exact FDA submission
  • Checked 2026-09-04
Monitoring
Monitor P000041 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.
  • Exact FDA submission
  • Checked 2026-09-04

Monitoring guidance is buyer-facing implementation guidance derived from the exact cleared scope; it is not a claim that the FDA package provides a live monitoring service.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to P000041 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared release includes them.

Deployment boundary

The exact public deployment topology remains incomplete; establish hosting responsibility, data flow, availability, upgrade, service, and downtime boundaries locally.

exact submission · checked 2026-09-04

FDA-described deployment boundaries do not establish current hosting contracts, security controls, uptime, or local qualification.

Interoperability acceptance

The exact public integration contract remains incomplete; establish and test supported input, output, identity, routing, archive, and downtime behavior locally.

exact submission · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-04

No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.

Lifecycle monitoring

Monitor P000041 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The canonical FDA PMA page describes an aid after initial physician interpretation; current supplements and labeling may change the applicable configuration and must be checked.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. PMA-authorized chest-radiograph computer-aided detection device limits remain submission-specific.

Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
P000041
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
X-ray/Radiography
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Anatomy
Adult chest; solitary pulmonary nodules 9-30 mm
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Clearance type
PMA
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2001-07-12
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-approved
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-20Last searched
27Fields reviewed
12Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, acr ai central product, fda decision material, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not publicly available - checked 2026-09-04 - Exact FDA submission

    No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Deployment: Not publicly available - checked 2026-09-04 - Exact FDA submission

    The exact public FDA decision material does not establish the complete deployment topology, hosting responsibility, availability, upgrade path, or service contract.

  • Integration: Not publicly available - checked 2026-09-04 - Exact FDA submission

    The exact public FDA decision material does not establish a complete integration contract. Confirm DICOM, worklist, identity, interfaces, exports, routing, audit behavior, and downtime locally.

  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Security: Not publicly available - checked 2026-09-04 - Exact FDA submission

    Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

  • Installation timeline: Not yet reviewed

7 sources - 3 history items

Source ledger

  1. FDA PMA decision material P000041: RAPIDSCREEN RS-2000

    U.S. Food and Drug Administration - Published 2001-07-12 - Accessed 2026-09-04

    Scope: identity, purpose, clinicalUse, modality, anatomy, intendedUsers, careSetting, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. ClearRead Detect model card (P000041)

    American College of Radiology - Published 2026-06-26 - Accessed 2026-09-01

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

Research history

  1. P000041 FDA decision

    Regulatory record

    PMA

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K231805

qXR-LN

Qure.ai Technologies

Authorized purpose: Second-reader CADe to identify and mark suspected pulmonary nodules 6-30 mm in the incidental adult population

Modality
X-ray/Radiography
Anatomy
Chest/lung, focused on suspected pulmonary nodules
Decision
2023-12-22
FDA-cleared K223133

VisiRad XR

Imidex Inc.

Authorized purpose: VisiRad XR is a computer-aided detection device that identifies and marks regions of interest suspicious for lung nodules and masses measuring 6-60 mm on chest radiographs in patients older than 21 years in outpatient or emergency-department settings.

Modality
X-ray/Radiography
Anatomy
Adult chest and pulmonary nodules or masses 6-60 mm
Decision
2023-08-03
FDA-cleared K252953

Velmeni for Dentists (V4D) Endo-Perio

Velmeni, Inc.

Authorized purpose: Concurrent-read CADe to assist dentists in detecting specified tooth and jaw anatomy, bone-level landmarks, and root-canal-treated teeth in digital radiographs of permanent teeth in patients 15 years or older.

Modality
X-ray/Radiography
Anatomy
Permanent teeth and jaw/maxillofacial anatomy, including enamel, dentine, pulp, root, mental foramen, inferior alveolar canal, maxillary sinus, cementoenamel junction, crestal bone, and root-canal-treated teeth
Decision
2026-05-11
FDA-cleared K253502

Critical Care Suite with Enteric Tube Positioning AI Algorithm

Ge Medical Systems, LLC

Authorized purpose: Analyze frontal chest and abdominal X-ray images to detect and localize a nasally or orally inserted enteric tube, its tip and side port if present, and the diaphragm and airways for radiologist review.

Modality
X-ray/Radiography
Anatomy
Chest/lung and abdomen/stomach; enteric tube, tube tip and side port, diaphragm, and airways including carina and left/right bronchi
Decision
2026-04-14

Correct this exact record

Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.

Open existing correction destination

Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.

Accepted repository change history

No entry has been added to this scoped change history for this record. This is not proof that the record never changed.

Correction policy and limits · Public repository change history