Authorized purpose: Rapid processes CT, CTP, CTA, diffusion MRI, and dynamic-contrast MRI for stroke viewing, perfusion, volumetry, mismatch, and large-vessel-density support for trained professionals.
Clinical role
Brain-image registration, segmentation, quantification, visualization, or procedure-planning support.
Images and patients
Radiological images; modality varies or is not specified in FDA list · Brain
Key limitation
Keep in mind: In addition to the Rapid imaging criteria, patients must meet the clinical requirements for thrombectomy, as assessed by the physician, and have none of the following contraindications or exclusions: Bolus Quality: absent or inadequate bolus. Patient Motion: excessive motion leading to artifacts that make the scan technically inadequate. Presence of hemorrhage.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: Rapid processes CT, CTP, CTA, diffusion MRI, and dynamic-contrast MRI for stroke viewing, perfusion, volumetry, mismatch, and large-vessel-density support for trained professionals.
Which images or clinical context are in scope?Modality: Radiological images; modality varies or is not specified in FDA list Anatomy or clinical context: Brain Input: Data and images are acquired through DICOM compliant imaging devices.
Who uses it?Intended users: trained professionals, including but not limited to physicians and medical technicians
What does the software produce?Output: It provides viewing, quantification, analysis and reporting capabilities. The CT analysis includes NCCT maps showing areas of hypodense and hyperdense tissue. The Dynamic Analysis Module includes calculation of parameters related to tissue flow (perfusion) and tissue blood volume.
What is its most important limitation?Key limitation: In addition to the Rapid imaging criteria, patients must meet the clinical requirements for thrombectomy, as assessed by the physician, and have none of the following contraindications or exclusions: Bolus Quality: absent or inadequate bolus. Patient Motion: excessive motion leading to artifacts that make the scan technically inadequate. Presence of hemorrhage.
Clinical takeaway. Clinical role: Rapid processes CT, CTP, CTA, diffusion MRI, and dynamic-contrast MRI for stroke viewing, perfusion, volumetry, mismatch, and large-vessel-density support for trained professionals.
Evidence takeaway. Evidence from the reviewed source record: K213165 reports software, algorithm, quantitative, interoperability, and workflow validation across the supported CT and MRI stroke-processing functions.
Evidence context
Evidence context not reviewed for this FDA record.
Public-label constraints
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Purpose
Rapid processes CT, CTP, CTA, diffusion MRI, and dynamic-contrast MRI for stroke viewing, perfusion, volumetry, mismatch, and large-vessel-density support for trained professionals.
Exact FDA submission
Checked 2026-09-19
Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.
It provides viewing, quantification, analysis and reporting capabilities. The CT analysis includes NCCT maps showing areas of hypodense and hyperdense tissue. The Dynamic Analysis Module includes calculation of parameters related to tissue flow (perfusion) and tissue blood volume.
Exact FDA submission
Checked 2026-09-19
The replacement retains the packet's viewing, analysis, maps, and calculated perfusion outputs without adding unsupported alerts or planning visualizations.
In addition to the Rapid imaging criteria, patients must meet the clinical requirements for thrombectomy, as assessed by the physician, and have none of the following contraindications or exclusions: Bolus Quality: absent or inadequate bolus. Patient Motion: excessive motion leading to artifacts that make the scan technically inadequate. Presence of hemorrhage.
Exact FDA submission
Checked 2026-09-19
The replacement uses the packet's direct physician-assessed thrombectomy boundary and listed contraindications/exclusions.
K213165 reports software, algorithm, quantitative, interoperability, and workflow validation across the supported CT and MRI stroke-processing functions.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
K213165 reports software, algorithm, quantitative, interoperability, and workflow validation across the supported CT and MRI stroke-processing functions.
Sensitivity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
Reported specificity
Not applicable
Not applicable
Not applicable
Checked 2026-09-03
Specificity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K213165 FDA performance package for Rapid
DesignManufacturer software, algorithm, quantitative, and workflow validation
PopulationAcute neuroimaging workflows using supported CT, perfusion, angiographic, and MR inputs
Scopeexact submission
Tested versionRapid release cleared in K213165
IndependenceSponsor or vendor study
K213165
Manufacturer evidence submitted for clearance or approval; local clinical, technical, and workflow acceptance remains necessary.
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K213165 by exact submission identifier. This does not exclude product-family or later safety information.
Public source
Exact FDA submission
Checked 2026-09-03
Exact-identifier review does not prove absence of all product-family safety signals.
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Acquisition/source
Source context, not route validation: Data and images are acquired through DICOM compliant imaging devices.
Scope: Exact FDA submission. This replaces the unsupported brain and clinical-workflow additions with the packet's direct acquisition statement.
Confirm scanner/model, protocol, series completeness and both software builds.
Source context, not route validation: DICOM import and output to PACS, workstations, or surgical systems; validate series selection, orientation, registration, measurements, routing, latency, and failure handling.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Source context, not route validation: It provides viewing, quantification, analysis and reporting capabilities. The CT analysis includes NCCT maps showing areas of hypodense and hyperdense tissue. The Dynamic Analysis Module includes calculation of parameters related to tissue flow (perfusion) and tissue blood volume.
Scope: Exact FDA submission. The replacement retains the packet's viewing, analysis, maps, and calculated perfusion outputs without adding unsupported alerts or planning visualizations.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Unresolved route: It provides viewing, quantification, analysis and reporting capabilities. The CT analysis includes NCCT maps showing areas of hypodense and hyperdense tissue. The Dynamic Analysis Module includes calculation of parameters related to tissue flow (perfusion) and tissue blood volume.
Scope: Exact FDA submission. The replacement retains the packet's viewing, analysis, maps, and calculated perfusion outputs without adding unsupported alerts or planning visualizations.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
Planned local route tests
No tests below have been performed or accepted.
Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.
Local implementation checklist
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
DICOM import and output to PACS, workstations, or surgical systems; validate series selection, orientation, registration, measurements, routing, latency, and failure handling.
RapidAI's current platform security and compliance one-pager states that its portfolio uses encryption at rest and in transit, role-based access control, monitoring/logging and listed HIPAA, GDPR, ISO 13485, ISO 27001, ISO 27701 and SOC 2 Type 1 claims.
Vendor-wide
Checked 2026-10-25
This is a current vendor-wide statement, not an independent attestation for the exact K223396 release; site-specific architecture, retention, contractual scope and current certification evidence remain unestablished.
Only qualified radiologists, neurologists, neurosurgeons, and trained imaging or surgical staff. should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Each module has distinct inputs, timing, and intended-use limits. Outputs support trained professionals and do not replace source-image review or treatment eligibility assessment.
DICOM import and output to PACS, workstations, or surgical systems; validate series selection, orientation, registration, measurements, routing, latency, and failure handling.
exact submission · checked 2026-09-03
Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Each module has distinct inputs, timing, and intended-use limits. Outputs support trained professionals and do not replace source-image review or treatment eligibility assessment.
exact submission · checked 2026-09-03
Define stop-use, escalation, rollback, and revalidation triggers before production use.
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-03
Vendor productivity claims are scenario inputs, not guaranteed local savings.
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Each module has distinct inputs, timing, and intended-use limits. Outputs support trained professionals and do not replace source-image review or treatment eligibility assessment.
exact submission · checked 2026-09-03
Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Radiological images; modality varies or is not specified in FDA list
FDA source
Exact FDA submission
Checked 2026-09-19
The exact packet explicitly identifies the supported CT, CTP, CTA, and MRI datasets and modules. Controlled directory display reconciled from exact FDA wording: CT, CT Perfusion (CTP), CT Angiography (CTA), and MRI including a Diffusion Weighted MRI (DWI) Module and a Dynamic Analysis Module. -> Radiological images; modality varies or is not specified in FDA list.
The packet names these vascular structures for the acute-stroke selection indication but does not state a general brain anatomy claim. Controlled directory display reconciled from exact FDA wording: intracranial internal carotid artery or proximal middle cerebral artery -> Brain.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
27Fields reviewed
14Source classes checked
20Screened PubMed leads
10Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, vendor security document, fda decision material, vendor product page, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Public pricing: Not publicly available - checked 2026-09-03 - Exact FDA submission
No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.
Authorized purpose: Cercare Neurosuite with Capillary Function and Oncology Virtual Expert processes CT or MR information to provide perfusion, tissue-blood-volume, diffusion, labeling, and quantification support for adult brain glioma workflows.
Modality
Radiological images; modality varies or is not specified in FDA list
Authorized purpose: Quantitative brain MRI and amyloid-PET analysis, including volumetric reference-percentile comparison and SUVR quantification, to support physician clinical evaluation.
Modality
Radiological images; modality varies or is not specified in FDA list
Authorized purpose: LumiNE converts adult CT or contrast-enhanced T1 MR images into reviewed three-dimensional models and displays two- and three-dimensional images in a browser or Microsoft HoloLens 2 for preoperative planning, not diagnosis.
Modality
Radiological images; modality varies or is not specified in FDA list
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
Accepted repository change history
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.