FDA-cleared profile

Overjet Calculus Assist

Overjet Inc. · X-ray/Radiography · FDA-cleared (510(k))

Authorized purpose: Concurrent-read CADe to aid professionally trained and licensed dentists in detecting interproximal calculus deposits on bitewing and periapical radiographs; the output is additional information and does not replace full dentist review or judgment.

Clinical role
Concurrent-read dental calculus detection with bounding-box annotation for dentist review in a non-diagnostic presentation layer; users can filter, display, hide, create, and edit annotations.
Images and patients
X-ray/Radiography · Interproximal tooth surfaces in dental/maxillofacial anatomy
Key limitation
Keep in mind: The software is not a replacement for a complete dentist review, full patient evaluation, or clinical judgment and must not be relied upon alone to make or confirm a diagnosis. Use is limited to professionally trained and licensed dentists and to the stated bitewing/periapical radiograph input of at least 500 x 500 pixels; the packet does not establish the generic product-code indication for other image types or interfaces.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: Concurrent-read CADe to aid professionally trained and licensed dentists in detecting interproximal calculus deposits on bitewing and periapical radiographs; the output is additional information and does not replace full dentist review or judgment.
  • Which images or clinical context are in scope?Modality: X-ray/Radiography Anatomy or clinical context: Interproximal tooth surfaces in dental/maxillofacial anatomy Input: Bitewing and periapical radiographs of at least 500 x 500 pixels; the FDA comparison table describes a subject population of patients requiring dental services, all sexes, with no age restriction.
  • Who uses it?Intended users: Professionally trained and licensed dentists
  • What does the software produce?Output: A bounding-box outline around suspected interproximal calculus on the radiograph, providing additional information for the dentist to use in diagnosing a tooth surface suspected of containing calculus deposits.
  • What is its most important limitation?Key limitation: The software is not a replacement for a complete dentist review, full patient evaluation, or clinical judgment and must not be relied upon alone to make or confirm a diagnosis. Use is limited to professionally trained and licensed dentists and to the stated bitewing/periapical radiograph input of at least 500 x 500 pixels; the packet does not establish the generic product-code indication for other image types or interfaces.

Clinical takeaway. Clinical role: Concurrent-read CADe to aid professionally trained and licensed dentists in detecting interproximal calculus deposits on bitewing and periapical radiographs; the output is additional information and does not replace full dentist review or judgment.

Evidence takeaway. Evidence from the reviewed source record: FDA standalone testing evaluated 296 bitewing and 322 periapical radiographs, with 6,121 and 3,595 surfaces respectively, using consensus ground truth from three US licensed dentists with oral-radiologist adjudication of non-consensus labels. Standalone sensitivity was 74.1% for bitewing images (95% CI 66.2%-82.0%) and 72.9% for periapical images (65.3%-80.5%); specificity was 99.4% for bitewing images (99.1%-99.6%) and 99.6% for periapical images (99.3%-99.8%). The 14-dentist reader study used 292 bitewing and 322 periapical radiographs; assisted reader sensitivity was 84.0% and 84.4%, versus 74.9% and 74.7% unassisted, while assisted specificity was 98.6% and 98.0%, versus 98.8% and 98.1% unassisted.

Evidence context

Evidence context not reviewed for this FDA record.

Public-label constraints

Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.

Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.

Purpose
Concurrent-read CADe to aid professionally trained and licensed dentists in detecting interproximal calculus deposits on bitewing and periapical radiographs; the output is additional information and does not replace full dentist review or judgment.
  • Exact FDA submission
  • Checked 2026-09-08
Workflow role
Concurrent-read dental calculus detection with bounding-box annotation for dentist review in a non-diagnostic presentation layer; users can filter, display, hide, create, and edit annotations.
  • Exact FDA submission
  • Checked 2026-09-08
Required input
Bitewing and periapical radiographs of at least 500 x 500 pixels; the FDA comparison table describes a subject population of patients requiring dental services, all sexes, with no age restriction.
  • Exact FDA submission
  • Checked 2026-09-08
Output and clinician action
A bounding-box outline around suspected interproximal calculus on the radiograph, providing additional information for the dentist to use in diagnosing a tooth surface suspected of containing calculus deposits.
  • Exact FDA submission
  • Checked 2026-09-08
Care setting
Dental practice imaging workflow using a practice management system, PACS, or EMR; the FDA packet does not identify a more specific facility type.
  • Exact FDA submission
  • Checked 2026-09-08
Intended users
Professionally trained and licensed dentists
  • Exact FDA submission
  • Checked 2026-09-08
Limitations
The software is not a replacement for a complete dentist review, full patient evaluation, or clinical judgment and must not be relied upon alone to make or confirm a diagnosis. Use is limited to professionally trained and licensed dentists and to the stated bitewing/periapical radiograph input of at least 500 x 500 pixels; the packet does not establish the generic product-code indication for other image types or interfaces.
  • Exact FDA submission
  • Checked 2026-09-08
Evidence summary
FDA standalone testing evaluated 296 bitewing and 322 periapical radiographs, with 6,121 and 3,595 surfaces respectively, using consensus ground truth from three US licensed dentists with oral-radiologist adjudication of non-consensus labels. Standalone sensitivity was 74.1% for bitewing images (95% CI 66.2%-82.0%) and 72.9% for periapical images (65.3%-80.5%); specificity was 99.4% for bitewing images (99.1%-99.6%) and 99.6% for periapical images (99.3%-99.8%). The 14-dentist reader study used 292 bitewing and 322 periapical radiographs; assisted reader sensitivity was 84.0% and 84.4%, versus 74.9% and 74.7% unassisted, while assisted specificity was 98.6% and 98.0%, versus 98.8% and 98.1% unassisted.
  • Exact FDA submission
  • Checked 2026-09-08

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
FDA standalone testing evaluated 296 bitewing and 322 periapical radiographs, with 6,121 and 3,595 surfaces respectively, using consensus ground truth from three US licensed dentists with oral-radiologist adjudication of non-consensus labels. Standalone sensitivity was 74.1% for bitewing images (95% CI 66.2%-82.0%) and 72.9% for periapical images (65.3%-80.5%); specificity was 99.4% for bitewing images (99.1%-99.6%) and 99.6% for periapical images (99.3%-99.8%). The 14-dentist reader study used 292 bitewing and 322 periapical radiographs; assisted reader sensitivity was 84.0% and 84.4%, versus 74.9% and 74.7% unassisted, while assisted specificity was 98.6% and 98.0%, versus 98.8% and 98.1% unassisted.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Reported sensitivity
Bitewing: 74.1% (95% CI 66.2%-82.0%); periapical: 72.9% (95% CI 65.3%-80.5%).
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

FDA K220928 reports separate surface-level standalone endpoints by radiograph type; reader-study results remain separate.

Reported specificity
Bitewing: 99.4% (95% CI 99.1%-99.6%); periapical: 99.6% (95% CI 99.3%-99.8%).
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

FDA K220928 reports separate surface-level standalone endpoints by radiograph type; reader-study results remain separate.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

Overjet Calculus Assist regulatory performance study summary

  • DesignStand-alone performance and reader study (ACR AI Central category)
  • PopulationAdult
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K220928
  • Samplen=618
  • IndependenceIndependence not established

K220928

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K220928. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08
Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not verified: Pricing information is recorded but not verified against a resolving source.

Reimbursement

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Integration chain: evidence at each hop

Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.

Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner

No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.

  1. Acquisition/source

    Source context, not route validation: Bitewing and periapical radiographs of at least 500 x 500 pixels; the FDA comparison table describes a subject population of patients requiring dental services, all sexes, with no age restriction.

    Scope: Exact FDA submission.

    Confirm scanner/model, protocol, series completeness and both software builds.

    Field checked 2026-09-08 · FDA K220928: Overjet Calculus Assist

  2. Routing

    Source context, not route validation: Overjet Calculus Assist is described as a module within the Overjet Platform; its network layer works with a practice PACS or EMR to transmit image and metadata to Overjet, and the presentation layer displays annotations in a non-diagnostic viewer. DICOM is listed among the compared image formats, but a specific interface version, local compatibility, or current commercial deployment topology is not established.

    Scope: Exact FDA submission.

    Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.

    Field checked 2026-09-08 · FDA K220928: Overjet Calculus Assist

  3. AI processing

    Source context, not route validation: The exact FDA package describes Overjet Calculus Assist as a cloud native application, contrasted with local software, with its platform listed as Web - Edge, Chrome, Firefox. Current hosting, data flow, and commercial configuration require vendor confirmation.

    Scope: Exact FDA submission. Packet wording: "A primary difference is the Carestream Logicon is a local software while Overjet Calculus Assist is a cloud native application." … "Platform Windows PC Web - Edge, Chrome, Firefox". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

    Confirm processing location, queue ownership, exclusions and exact AI build.

    Field checked 2026-11-14 · FDA K220928: Overjet Calculus Assist

  4. Returned objects

    Source context, not route validation: A bounding-box outline around suspected interproximal calculus on the radiograph, providing additional information for the dentist to use in diagnosing a tooth surface suspected of containing calculus deposits.

    Scope: Exact FDA submission.

    Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.

    Field checked 2026-09-08 · FDA K220928: Overjet Calculus Assist

  5. Viewer/worklist/report

    Unresolved route: A bounding-box outline around suspected interproximal calculus on the radiograph, providing additional information for the dentist to use in diagnosing a tooth surface suspected of containing calculus deposits.

    Scope: Exact FDA submission.

    Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.

    Field checked 2026-09-08 · FDA K220928: Overjet Calculus Assist

  6. Support owner

    Unresolved route: Not established for the exact route.

    Scope: Scope not established.

    Name the local, platform and AI supplier support owners and escalation path.

Planned local route tests

No tests below have been performed or accepted.

  1. Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
  2. Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
  3. Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
  4. Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
  5. Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
  6. Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
  7. Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Deployment
The exact FDA package describes Overjet Calculus Assist as a cloud native application, contrasted with local software, with its platform listed as Web - Edge, Chrome, Firefox. Current hosting, data flow, and commercial configuration require vendor confirmation.
  • Exact FDA submission
  • Checked 2026-11-14

Packet wording: "A primary difference is the Carestream Logicon is a local software while Overjet Calculus Assist is a cloud native application." … "Platform Windows PC Web - Edge, Chrome, Firefox". Read from the exact FDA decision document on 2026-11-14; this is the release-level description, not current commercial configuration.

Integration
Overjet Calculus Assist is described as a module within the Overjet Platform; its network layer works with a practice PACS or EMR to transmit image and metadata to Overjet, and the presentation layer displays annotations in a non-diagnostic viewer. DICOM is listed among the compared image formats, but a specific interface version, local compatibility, or current commercial deployment topology is not established.
  • Exact FDA submission
  • Checked 2026-09-08
Security
Overjet's trust center states a completed independent HITRUST audit and certification, HIPAA business associate compliance, GDPR and CCPA alignment, third-party penetration tests, need-to-know data access and employee security training. Vendor-wide.
  • Vendor-wide
  • Checked 2026-10-25

Vendor statement, not an attestation; exact-release scope is not established.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for Overjet Calculus Assist; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-08
Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K220928
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
X-ray/Radiography
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Anatomy
Interproximal tooth surfaces in dental/maxillofacial anatomy
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2022-12-16
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
24Fields reviewed
10Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, vendor documentation, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not verified - checked 2026-09-08 - Exact FDA submission

    No public price or quote for the exact K220928 configuration was established in this review.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Reimbursement: Not publicly available - checked 2026-09-08 - Exact FDA submission

    No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Installation timeline: Not yet reviewed
  • Training: Not verified - checked 2026-09-08 - Exact FDA submission

    Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

  • Monitoring: Not verified - checked 2026-09-08 - Exact FDA submission

    Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

8 sources - 3 history items

Source ledger

  1. FDA K220928: Overjet Calculus Assist

    U.S. Food and Drug Administration - Published 2022-12-16 - Accessed 2026-09-08

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, deployment

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. Overjet Calculus Assist model card (K220928)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, reportedSensitivity, reportedSpecificity, evidenceSummary, anatomy, evidenceStudies

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K220928

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

  8. Overjet Trust Center

    Overjet - Accessed 2026-10-25

    Scope: security

Research history

  1. K220928 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K252953

Velmeni for Dentists (V4D) Endo-Perio

Velmeni, Inc.

Authorized purpose: Concurrent-read CADe to assist dentists in detecting specified tooth and jaw anatomy, bone-level landmarks, and root-canal-treated teeth in digital radiographs of permanent teeth in patients 15 years or older.

Modality
X-ray/Radiography
Anatomy
Permanent teeth and jaw/maxillofacial anatomy, including enamel, dentine, pulp, root, mental foramen, inferior alveolar canal, maxillary sinus, cementoenamel junction, crestal bone, and root-canal-treated teeth
Decision
2026-05-11
FDA-cleared K253502

Critical Care Suite with Enteric Tube Positioning AI Algorithm

Ge Medical Systems, LLC

Authorized purpose: Analyze frontal chest and abdominal X-ray images to detect and localize a nasally or orally inserted enteric tube, its tip and side port if present, and the diaphragm and airways for radiologist review.

Modality
X-ray/Radiography
Anatomy
Chest/lung and abdomen/stomach; enteric tube, tube tip and side port, diaphragm, and airways including carina and left/right bronchi
Decision
2026-04-14
FDA-cleared K251934

qXR-Detect

Qure.Ai Technologies

Authorized purpose: qXR-Detect is an adult chest-radiograph concurrent reading aid that identifies, highlights and categorizes suspicious regions of interest across lung, pleura, mediastinum/hila/heart, bone, hardware and other categories; trained clinicians remain responsible for primary interpretation.

Modality
X-ray/Radiography
Anatomy
Chest/Lung; pleura, mediastinum/hila/heart, bone, hardware and other chest-radiograph regions
Decision
2026-01-16
FDA-cleared K250264

SugarBug (1.x)

Bench7, Inc.

Authorized purpose: Provides automated concurrent-read detection and segmentation of caries on bitewing radiographs in patients 18 and older, adding information for the dentist while requiring complete dentist review and judgment.

Modality
X-ray/Radiography
Anatomy
Dental/Maxillofacial
Decision
2025-11-07

Correct this exact record

Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.

Open existing correction destination

Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.

Accepted repository change history

No entry has been added to this scoped change history for this record. This is not proof that the record never changed.

Correction policy and limits · Public repository change history