Authorized purpose: MAGNETOM Skyra Fit with syngo MR XA50A is a 3T system for broad head, body, and extremity MRI; this release includes TSE motion correction and automatic breast-biopsy fiducial detection.
Clinical role
MRI acquisition, reconstruction, review, and release-specific workflow support.
Images and patients
MRI · Multi-region
Key limitation
Keep in mind: These images and/or spectra and the physical parameters derived from the images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
Overview status: FDA-bounded overview This overview only restates exact FDA-supported facts. It does not use candidate literature or vendor claims, and it is not a full source or clinician review.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: MAGNETOM Skyra Fit with syngo MR XA50A is a 3T system for broad head, body, and extremity MRI; this release includes TSE motion correction and automatic breast-biopsy fiducial detection.
Which images or clinical context are in scope?Input: Not established in the reviewed exact FDA decision-summary packet. Confirm the current supported scope with manufacturer documentation and local policy.
Who uses it?Intended users: healthcare professionals familiar with and responsible for the acquisition and post processing of magnetic resonance images.
What does the software produce?Output: The MAGNETOM system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
What is its most important limitation?Key limitation: These images and/or spectra and the physical parameters derived from the images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
Clinical takeaway. Clinical role: MAGNETOM Skyra Fit with syngo MR XA50A is a 3T system for broad head, body, and extremity MRI; this release includes TSE motion correction and automatic breast-biopsy fiducial detection.
Evidence takeaway. FDA record boundary: K220589 reports bench, software, and sample-image testing; no additional clinical study was required.
Evidence context
Evidence context not reviewed for this FDA record.
Public-label constraints
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Purpose
MAGNETOM Skyra Fit with syngo MR XA50A is a 3T system for broad head, body, and extremity MRI; this release includes TSE motion correction and automatic breast-biopsy fiducial detection.
Exact FDA submission
Checked 2026-09-19
Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.
The MAGNETOM system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
Exact FDA submission
Checked 2026-09-19
This replaces reconstructed-image and generic workflow-result wording with the packet's direct outputs.
These images and/or spectra and the physical parameters derived from the images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
Exact FDA submission
Checked 2026-09-19
The packet states the trained-physician interpretation boundary; it does not state the dossier's model, release, and option-mapping limitation.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
K220589 reports bench, software, and sample-image testing; no additional clinical study was required.
Sensitivity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
Reported specificity
Not applicable
Not applicable
Not applicable
Checked 2026-09-03
Specificity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K220589 FDA performance package for MAGNETOM Skyra Fit
DesignManufacturer nonclinical system, software, and sample-image verification
PopulationBroad diagnostic MRI applications on upgraded MAGNETOM Skyra Fit systems
Scopeexact submission
Tested versionMAGNETOM Skyra Fit with syngo MR XA50A
IndependenceSponsor or vendor study
K220589
Manufacturer evidence submitted for clearance or approval; local clinical, technical, and workflow acceptance remains necessary.
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
2 reviewed FDA recall records in the 2026-09-02 openFDA snapshot natively identify K220589. Confirm affected model, version, unit, correction, and current manufacturer instructions. FDA recall Z-2661-2025 affects specified MAGNETOM Skyra fit systems. Ice blockage in magnet venting could prevent helium from escaping during a quench and cause pressure buildup or helium leakage. FDA lists the recall as open and classified. FDA recall Z-2662-2025 affects specified MAGNETOM Skyra Fit BioMatrix systems. Ice blockage in magnet venting could prevent helium from escaping during a quench and cause pressure buildup or helium leakage. FDA lists the recall as open and classified.
FDA source
Exact product version
Checked 2026-09-04
Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Acquisition/source
Unresolved route: Not established for the exact route.
Scope: Exact FDA submission. Previous value withdrawn: The exact FDA decision-summary packet reviewed on 2026-09-19 does not establish this claim.
Confirm scanner/model, protocol, series completeness and both software builds.
Field checked 2026-09-19 ·
Routing
Source context, not route validation: Scanner-console and DICOM workflow to PACS or downstream applications; validate worklist, identifiers, series labels, geometry, measurements, routing, and archive completeness.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Source context, not route validation: The MAGNETOM system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
Scope: Exact FDA submission. This replaces reconstructed-image and generic workflow-result wording with the packet's direct outputs.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Unresolved route: The MAGNETOM system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
Scope: Exact FDA submission. This replaces reconstructed-image and generic workflow-result wording with the packet's direct outputs.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
Planned local route tests
No tests below have been performed or accepted.
Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.
Local implementation checklist
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Scanner-console and DICOM workflow to PACS or downstream applications; validate worklist, identifiers, series labels, geometry, measurements, routing, and archive completeness.
Siemens Healthineers' corporate cybersecurity page states a Secure Development Lifecycle addressing pre-market and post-market phases for products under development and a range of existing offerings; a Cybersecurity Management Service maintaining a product security inventory (over 1,000 product versions and over 21,000 monitored software components) with security whitepapers, SBOMs and vulnerability assessments available to customers via teamplay Fleet; incident and vulnerability management channels; and that Siemens Healthineers AG maintains an independent certification of its global Cybersecurity Management System to ISO/IEC 27001:2022 extended by ISO/IEC 27701:2019, with the certificate referenced to the SGS directory. Vendor statement; no certificate or report was read.
Vendor-wide
Checked 2026-10-26
Vendor statement, not an attestation. Identity bridge: Siemens Healthineers' own corporate-info page names Siemens Medical Solutions USA, Inc. (Malvern, PA), and its 2024 governance press release states Siemens Healthcare GmbH's business was transferred to Siemens Healthineers AG. Corporate program statement; exact-release scope is not established.
Only qualified mri technologists and physicians trained in magnetic resonance imaging. should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Field strength, coil, sequence, anatomy, population, and optional-feature limits vary by model and release; map the installed configuration to the exact clearance and labeling.
Scanner-console and DICOM workflow to PACS or downstream applications; validate worklist, identifiers, series labels, geometry, measurements, routing, and archive completeness.
exact submission · checked 2026-09-03
Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Field strength, coil, sequence, anatomy, population, and optional-feature limits vary by model and release; map the installed configuration to the exact clearance and labeling.
exact submission · checked 2026-09-03
Define stop-use, escalation, rollback, and revalidation triggers before production use.
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-03
Vendor productivity claims are scenario inputs, not guaranteed local savings.
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Field strength, coil, sequence, anatomy, population, and optional-feature limits vary by model and release; map the installed configuration to the exact clearance and labeling.
exact submission · checked 2026-09-03
Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
This audit distinguishes completed source review from fields that have not yet been researched.
Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
10Source classes checked
0Awaiting review PubMed leads
1Awaiting review trial leads
0Unreviewed FDA recall leads
Recovered from the prior exact-submission extraction and normalized under the current provenance rules. Exact FDA packet assessed on 2026-09-19. Directory-backed facts were reconciled only where purpose, modality, and anatomy were each directly established. Candidate literature and postmarket candidates remain in their existing review state. Automated exact-name discovery found 0 PubMed and 1 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. 2 FDA recall candidates were manually reviewed: 2 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 2 postmarket candidate records; 2 have been reviewed (2 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, fda decision material, vendor product page, reimbursement policy, fda device recall, fda decision summary packet, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Required input: Withdrawn - checked 2026-09-19 - Exact FDA submission
Previous value withdrawn: The exact FDA decision-summary packet reviewed on 2026-09-19 does not establish this claim.
Public pricing: Not publicly available - checked 2026-09-03 - Exact FDA submission
No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.
Authorized purpose: Sonic DL is optional integrated GE MRI reconstruction for supported 2D cardiac cine and 3D fast-spin-echo or gradient-echo acquisitions at 1.5T, 3T, and 7T for all ages and anatomies; very high acceleration can reduce small low-contrast lesion detectability.
Authorized purpose: SubtleMR is MRI image-processing software for reducing noise in supported head, spine, neck, abdomen, pelvis, prostate, breast, and musculoskeletal MRI or increasing sharpness for head MRI within the labeled workflow.
Authorized purpose: Vantage Fortian and Orian 1.5T produce diagnostic MR images of the head and body, including labeled noncontrast angiography, for trained technologists and physician interpretation.
Authorized purpose: S-scan Open is an Esaote MR system for diagnostic image acquisition, reconstruction, display, and professional interpretation within the labeled scanner, coil, sequence, and anatomy scope.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
Accepted repository change history
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.