Blinded review panel
20 radiation oncologists
- EndpointReviewers in the multi-vendor contouring study
- PopulationMulti-region radiotherapy contour review
- Tested versionART-Plan product family; exact build not reported
FDA-cleared profile
TheraPanacea · Radiotherapy Planning Imaging · FDA-cleared (510(k))
Authorized purpose: ART-Plan assists trained radiation therapy professionals with DICOM CT, MR, and PET image visualization, rigid and deformable registration, and automatic or assisted contouring for treatment planning, with qualified review before export.
Overview status: Source-reviewed overview
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
Clinical takeaway. Clinical role: ART-Plan assists trained radiation therapy professionals with DICOM CT, MR, and PET image visualization, rigid and deformable registration, and automatic or assisted contouring for treatment planning, with qualified review before export.
Evidence takeaway. Evidence from the reviewed source record: FDA submissions document release-specific software verification, contouring validation, registration checks, and, where applicable, synthetic-CT, dose, planning, or adaptation testing. Independent multi-vendor studies support clinical usefulness but also show structure- and site-dependent editing needs; they do not validate every ART-Plan release or establish patient-outcome benefit.
Evidence context not reviewed for this FDA record.
Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.
Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.
Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.
The exact packet supports these modalities and DICOM 3.0 datasets but does not establish the later-release CBCT, 4D-CT, RT Structure Set, prescription, or adaptation-parameter list.
The exact packet supports delineated structures and fusion results for dosimetry, not the later-release synthetic-CT, dose, replanning-metric, or automatic-plan list.
The exact packet states trained users or professionals with qualifications in anatomy and radiotherapy but does not list the dossier's specific job titles.
This is the exact review, modification, and validation boundary in the packet.
Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Sensitivity is not an applicable primary endpoint for this radiation-planning software. Review structure-, model-, workflow-, and release-specific geometric, clinical-review, dosimetric, and edit-burden evidence instead.
Specificity is not an applicable primary endpoint for this radiation-planning software. Review structure-, model-, workflow-, and release-specific geometric, clinical-review, dosimetric, and edit-burden evidence instead.
20 radiation oncologists
K202700
Manufacturer evidence submitted for substantial equivalence. The initial cleared release combined SmartFuse multimodal registration with Annotate automatic and assisted contouring for CT, MR, and PET DICOM data.
PMCID PMC11580215
The study reported that all evaluated systems required physician correction and should not be treated as exact-version validation.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
A zero-result exact-identifier search does not prove that no recall, correction, adverse-event report, or product-family safety signal exists. Maintain ongoing FDA and vendor surveillance.
Price not public here; enter your quote
Not publicly available: Reviewed sources do not publish an exact-product procurement price with a stated offer scope.
No separate named-product payment identified in reviewed CMS material
Centers for Medicare & Medicaid Services · United StatesBuild a local total-cost and value model; do not infer reimbursement from FDA clearance.
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.
Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner
No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.
Source context, not route validation: DICOM 3.0 compliant datasets, including static and gated CT, PET, and MR.
Scope: Exact FDA submission. The exact packet supports these modalities and DICOM 3.0 datasets but does not establish the later-release CBCT, 4D-CT, RT Structure Set, prescription, or adaptation-parameter list.
Confirm scanner/model, protocol, series completeness and both software builds.
Field checked 2026-09-19 · FDA K202700: ART-Plan
Source context, not route validation: DICOM 3.0 import, export, and network exchange with imaging systems and treatment-planning systems; exact supported objects and automation depend on the cleared release and local configuration.
Scope: Exact FDA submission.
Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.
Field checked 2026-09-03 · FDA K202700: ART-Plan · ART-Plan AI application suite for radiotherapy
Source context, not route validation: Software platform used in radiation-therapy hospitals and clinics. FDA summaries describe account-based projects, browser-accessible functions in later releases, DICOM network exchange, and batch-mode operations; hosting, tenancy, interfaces, and compute sizing require site-specific confirmation.
Scope: Exact FDA submission.
Confirm processing location, queue ownership, exclusions and exact AI build.
Field checked 2026-09-03 · FDA K202700: ART-Plan · ART-Plan AI application suite for radiotherapy
Source context, not route validation: Delineated structures and registration/fusion results for use in the dosimetry process.
Scope: Exact FDA submission. The exact packet supports delineated structures and fusion results for dosimetry, not the later-release synthetic-CT, dose, replanning-metric, or automatic-plan list.
Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.
Field checked 2026-09-19 · FDA K202700: ART-Plan
Unresolved route: Delineated structures and registration/fusion results for use in the dosimetry process.
Scope: Exact FDA submission. The exact packet supports delineated structures and fusion results for dosimetry, not the later-release synthetic-CT, dose, replanning-metric, or automatic-plan list.
Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.
Field checked 2026-09-19 · FDA K202700: ART-Plan
Unresolved route: Not established for the exact route.
Scope: Scope not established.
Name the local, platform and AI supplier support owners and escalation path.
No tests below have been performed or accepted.
Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.
Vendor statement, not an attestation. The page is on therapanacea.com and describes TheraPanacea's radiotherapy planning and delivery software; the FDA applicant name variants (TheraPanacea, Therapanacea SAS) match. Company-wide statement; exact-release scope is not established.
The initial cleared release combined SmartFuse multimodal registration with Annotate automatic and assisted contouring for CT, MR, and PET DICOM data. Procurement should map the installed build, modules, models, anatomies, inputs, and outputs to K202700 before acceptance.
exact submission · checked 2026-09-03Later product-family features are not evidence that an earlier cleared release includes them.
DICOM 3.0 import, export, and network exchange with imaging systems and treatment-planning systems; exact supported objects and automation depend on the cleared release and local configuration.
exact submission · checked 2026-09-03Test representative imports, exports, identifiers, orientation, geometry, structure names, units, failure handling, and round trips in the local environment.
Use a signed local test set spanning supported anatomies, scanners, protocols, unusual or postsurgical anatomy, and small or complex structures. Measure edit burden, rejection, downstream plan effects, and reviewer agreement rather than relying only on average overlap metrics.
product family · checked 2026-09-03Define stop-use, escalation, rollback, and revalidation triggers before production use.
Model total annual and per-plan cost against hands-on and elapsed time after review, correction, failed transfers, rework, support, upgrades, downtime, and any effect on plan quality or throughput.
product family · checked 2026-09-03Vendor time-saving results are scenario inputs, not guaranteed local savings.
Monitor by exact software and model version, anatomy, structure, scanner and protocol, patient position, contrast, unusual or postsurgical anatomy, reviewer role, edit time, rejected outputs, DICOM-transfer failures, downstream plan effects, incidents, recalls, and updates. Revalidate after material workflow or model changes.
product family · checked 2026-09-03Trend failures and edits by exact software version, model, anatomy, scanner, protocol, and site.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
The refreshed discovery snapshot contains 20 PubMed and 1 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 1 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, vendor product page, peer reviewed publication, health technology guidance, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
No public list price for the exact cleared release was found. Obtain a written quote separating license basis, sites or users, enabled modules or models, implementation, interfaces, compute, storage, training, support, upgrades, renewal, and exit costs.
12 sources - 3 history items
Scope: purpose, modality, anatomy, intendedUsers, input, output, limitations, evidenceSummary, clinicalUse
Scope: regulatoryIdentity, modalityContext
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: reimbursement, radiationTherapyPaymentContext
Scope: limitations, training, pricing, evidenceSummary, economics, monitoring, implementationCapabilities
Scope: productFamily, workflowRole, integration, deployment, currentCommercialContext, implementationCapabilities
Scope: workflowRole, integration, deployment, currentCommercialContext, implementationCapabilities
Scope: limitations, evidenceSummary, evidenceStudy, evidenceMetrics, monitoring, implementationCapabilities
Scope: limitations, evidenceSummary, economics, monitoring, implementationCapabilities
Scope: security
Regulatory record
510(k)
Research record
fda record reviewed
Editorial review
Source-reviewed editorial overlay
Alternatives
Radformation, Inc.
Authorized purpose: AutoContour Model RADAC V5 assists radiation treatment planners with contouring and reviewing structures in medical images for radiation therapy treatment planning. It produces initial machine-learning contours for user review and modification; it does not independently approve a contour or treatment plan.
Elekta Solutions AB
Authorized purpose: The EMLA family delivers external-beam radiation therapy for adult and pediatric patients with benign, malignant, or metastatic disease. Authorized techniques vary by model: Synergy and Harmony include conventional and fractionated delivery; Infinity and Harmony Pro add SBRT/SABR; Versa HD and Evo also support SRS and specified functional disorders.
Therapanacea Sas
Authorized purpose: ART-Plan+ assists trained radiation-therapy professionals with multimodal image review, registration, contouring, and the release-specific planning functions described in K253091. This release combined Annotate, prostate SmartPlan, and AdaptBox for supported head-and-neck, breast or thorax, and male-pelvis offline adaptive workflows, and added structures without changing the core indication.
Oncospace, Inc.
Authorized purpose: Oncospace supports trained radiation therapy professionals with protocol configuration, machine-learning achievable-dose prediction, planning-objective exchange, and plan review across head-and-neck, thoracic, abdominal, and pelvic workflows using locked models.
Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.
Open existing correction destinationPermission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.
No entry has been added to this scoped change history for this record. This is not proof that the record never changed.
Correction policy and limits · Public repository change history