FDA-cleared profile

3DXR

GE Medical Systems SCS · Fluoroscopy/Angiography · FDA-cleared (510(k))

Authorized purpose: 3DXR reconstructs cone-beam CT from interventional X-ray acquisitions and uses CleaRecon DL to reduce streak artifacts for display in the advanced workstation workflow.

Clinical role
Image reconstruction, localization, navigation, or procedural guidance under direct professional control.
Images and patients
Fluoroscopy/Angiography · Multi-region
Key limitation
Keep in mind: The CleaRecon DL option is validated for adult population only.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: 3DXR reconstructs cone-beam CT from interventional X-ray acquisitions and uses CleaRecon DL to reduce streak artifacts for display in the advanced workstation workflow.
  • Which images or clinical context are in scope?Modality: Fluoroscopy/Angiography Anatomy or clinical context: Multi-region Input: Any images acquired with a 3D Acquisition mode of the X-ray interventional system.
  • Who uses it?Intended users: Physician.
  • What does the software produce?Output: The reconstructed 3D volume is visualized under Volume Viewer.
  • What is its most important limitation?Key limitation: The CleaRecon DL option is validated for adult population only.

Clinical takeaway. Clinical role: 3DXR reconstructs cone-beam CT from interventional X-ray acquisitions and uses CleaRecon DL to reduce streak artifacts for display in the advanced workstation workflow.

Evidence takeaway. Evidence from the reviewed source record: K243446 reports a retrospective clinical image-quality study of 110 patients from 13 sites reviewed by 13 clinicians, plus nonclinical reconstruction validation.

Evidence context

Evidence context not reviewed for this FDA record.

Public-label constraints

Label constraints have not been reviewed for this exact FDA record. Unknown is not all ages or evidence of unsuitability.

Public-label constraints, not patient-level eligibility or a medical recommendation. Training and evaluation populations are separate. Read the original labeling and confirm the exact release and protocol.

Purpose
3DXR reconstructs cone-beam CT from interventional X-ray acquisitions and uses CleaRecon DL to reduce streak artifacts for display in the advanced workstation workflow.
  • Exact FDA submission
  • Checked 2026-09-19

Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.

Workflow role
Image reconstruction, localization, navigation, or procedural guidance under direct professional control.
  • Exact FDA submission
  • Checked 2026-09-03
Required input
Any images acquired with a 3D Acquisition mode of the X-ray interventional system.
  • Exact FDA submission
  • Checked 2026-09-19

The exact input is 3D-acquisition images from the X-ray interventional system, not the dossier's multi-modality image set and user-input wording.

Output and clinician action
The reconstructed 3D volume is visualized under Volume Viewer.
  • Exact FDA submission
  • Checked 2026-09-19

The packet identifies the reconstructed 3D volume and Volume Viewer output, not the dossier's generic landmarks, measurements, overlays, or navigation guidance.

Care setting
Hospital imaging, interventional, operating-room, or procedure-suite workflows within the cleared indication.
  • Exact FDA submission
  • Checked 2026-09-03
Intended users
Physician.
  • Exact FDA submission
  • Checked 2026-09-19

The indications statement says the reconstructed volume assists the physician and does not establish technologists or procedural staff as intended users.

Limitations
The CleaRecon DL option is validated for adult population only.
  • Exact FDA submission
  • Checked 2026-09-19

The packet's comparison table gives the adult-population validation boundary for CleaRecon DL.

Evidence summary
K243446 reports a retrospective clinical image-quality study of 110 patients from 13 sites reviewed by 13 clinicians, plus nonclinical reconstruction validation.
  • Exact FDA submission
  • Checked 2026-09-03

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
K243446 reports a retrospective clinical image-quality study of 110 patients from 13 sites reviewed by 13 clinicians, plus nonclinical reconstruction validation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Sensitivity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Specificity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Clinical evaluation patients

110 patients

  • EndpointRetrospective CleaRecon DL image-quality evaluation
  • Population3DXR
  • Tested version3DXR release with CleaRecon DL

Clinical readers

13 readers

  • EndpointMultireader image-quality review
  • Population3DXR
  • Tested version3DXR release with CleaRecon DL

K243446 FDA performance package for 3DXR

  • DesignManufacturer retrospective multicenter, multireader image-quality study and nonclinical validation
  • PopulationAdult interventional cone-beam CT cases from multiple anatomies and sites
  • Scopeexact submission
  • Tested version3DXR release with CleaRecon DL
  • Samplen=110
  • Sites13
  • IndependenceSponsor or vendor study

K243446

Manufacturer evidence submitted for clearance or approval; local clinical, technical, and workflow acceptance remains necessary.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K243446 by exact submission identifier. This does not exclude product-family or later safety information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

Exact-identifier review does not prove absence of all product-family safety signals.

Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not publicly available: Reviewed sources do not publish an exact-product procurement price with a stated offer scope.

Reimbursement

Reimbursement
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
  • Service-level, not product-specific
  • Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Integration chain: evidence at each hop

Public source context, not tested interoperability. Each hop needs its own release/configuration evidence. Missing or unavailable routes are not documented incompatibility. All local tests are planned, not passed; no installed-system acceptance is recorded.

Acquisition/source → routing → AI processing → returned objects → viewer/worklist/report → support owner

No specific route context has been source-reviewed for this record. Obtain both endpoint builds and documents; this is not a finding of incompatibility.

  1. Acquisition/source

    Source context, not route validation: Any images acquired with a 3D Acquisition mode of the X-ray interventional system.

    Scope: Exact FDA submission. The exact input is 3D-acquisition images from the X-ray interventional system, not the dossier's multi-modality image set and user-input wording.

    Confirm scanner/model, protocol, series completeness and both software builds.

    Field checked 2026-09-19 · FDA K243446: 3DXR

  2. Routing

    Source context, not route validation: Validate compatible imaging hardware, acquisition geometry, displays, workstation, exported objects, latency, calibration, and fallback workflow.

    Scope: Exact FDA submission.

    Name gateways, destinations, transfer rules and failure visibility; a DICOM statement does not prove a route.

    Field checked 2026-09-03 · FDA K243446: 3DXR

  3. AI processing

    Source context, not route validation: Procedure-room hardware and software or a connected workstation with supported imaging equipment and accessories.

    Scope: Exact FDA submission.

    Confirm processing location, queue ownership, exclusions and exact AI build.

    Field checked 2026-09-03 · FDA K243446: 3DXR

  4. Returned objects

    Source context, not route validation: The reconstructed 3D volume is visualized under Volume Viewer.

    Scope: Exact FDA submission. The packet identifies the reconstructed 3D volume and Volume Viewer output, not the dossier's generic landmarks, measurements, overlays, or navigation guidance.

    Confirm object classes, units, references and whether findings, overlays or measurements reach their intended destination.

    Field checked 2026-09-19 · FDA K243446: 3DXR

  5. Viewer/worklist/report

    Unresolved route: The reconstructed 3D volume is visualized under Volume Viewer.

    Scope: Exact FDA submission. The packet identifies the reconstructed 3D volume and Volume Viewer output, not the dossier's generic landmarks, measurements, overlays, or navigation guidance.

    Confirm the named viewer/worklist/report build, display behavior and report transfer. Output support alone does not establish this endpoint. The displayed source describes output, not validated end-to-end delivery.

    Field checked 2026-09-19 · FDA K243446: 3DXR

  6. Support owner

    Unresolved route: Not established for the exact route.

    Scope: Scope not established.

    Name the local, platform and AI supplier support owners and escalation path.

Planned local route tests

No tests below have been performed or accepted.

  1. Patient/study identity (planned). Use approved non-patient test data to verify identifiers, accession and result-to-study linkage at every hop.
  2. Study completeness (planned). Test missing views/series, partial transfer, late arrivals, priors and unsupported acquisition inputs; confirm explicit refusal or fallback.
  3. Ordering and duplicates (planned). Send out-of-order, repeated and corrected studies; verify worklist order, deduplication and no misleading stale results.
  4. Report transfer (planned). Verify output object types, annotations, units, report content, destination and availability of original images.
  5. Access (planned). Verify authorized roles, audit trail, denied access and support ownership at each destination.
  6. Latency and failures (planned). Agree a workload and turnaround target; test queues, timeouts, missing results and fallback reading.
  7. Updates and rollback (planned). Define version change control, revalidation triggers, stop-use criteria and a tested rollback route.

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Deployment
Procedure-room hardware and software or a connected workstation with supported imaging equipment and accessories.
  • Exact FDA submission
  • Checked 2026-09-03
Integration
Validate compatible imaging hardware, acquisition geometry, displays, workstation, exported objects, latency, calibration, and fallback workflow.
  • Exact FDA submission
  • Checked 2026-09-03
Training
Only qualified physicians, technologists, or procedural staff trained for the specified intervention. should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • Exact FDA submission
  • Checked 2026-09-03
Monitoring
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: The operator remains responsible for procedural decisions, source-image review, landmark confirmation, and fallback when inputs, tracking, calibration, or output quality are inadequate.
  • Exact FDA submission
  • Checked 2026-09-03

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, and outputs to K243446 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

Validate compatible imaging hardware, acquisition geometry, displays, workstation, exported objects, latency, calibration, and fallback workflow.

exact submission · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The operator remains responsible for procedural decisions, source-image review, landmark confirmation, and fallback when inputs, tracking, calibration, or output quality are inadequate.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

Vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: The operator remains responsible for procedural decisions, source-image review, landmark confirmation, and fallback when inputs, tracking, calibration, or output quality are inadequate.

exact submission · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.

Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K243446
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Fluoroscopy/Angiography
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The packet's classification name is an image-intensified fluoroscopic x-ray system; it does not use the dossier's Fluoroscopy/Angiography label. Controlled directory display reconciled from exact FDA wording: Image-intensified fluoroscopic x-ray system. -> Fluoroscopy/Angiography.

Anatomy
Multi-region
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2025-02-25
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
27Fields reviewed
11Source classes checked
3Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains 3 PubMed and 0 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 3 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, fda decision material, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not publicly available - checked 2026-09-03 - Exact FDA submission

    No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Security: Not verified - checked 2026-09-03 - Exact FDA submission

    Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

  • Installation timeline: Not yet reviewed

6 sources - 3 history items

Source ledger

  1. FDA K243446: 3DXR

    U.S. Food and Drug Administration - Published 2025-02-25 - Accessed 2026-09-19

    Scope: purpose, anatomy, evidenceSummary, modality, intendedUsers, input, output, limitations, clinicalUse

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  4. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  5. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

Research history

  1. K243446 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K222070

EndoNaut

Therenva SAS

Authorized purpose: EndoNaut fuses planning images with live fluoroscopy and provides computerized navigation support for fluoroscopy-guided aneurysm repair, embolization, and peripheral-artery procedures involving the chest, abdomen, pelvis, neck, or lower limbs.

Modality
Fluoroscopy/Angiography
Anatomy
Multi-region
Decision
2022-10-25
FDA-cleared K250660

LUMINOS Q.namix T; LUMINOS Q.namix R

Siemens Medical Solutions

Authorized purpose: LUMINOS Q.namix T and LUMINOS Q.namix R are multifunctional radiography and fluoroscopy systems for routine radiography and fluoroscopic examinations including gastrointestinal, urogenital, arthrographic, angiographic, and pediatric workflows; they are not mammography systems.

Modality
Fluoroscopy/Angiography
Anatomy
Multi-region
Decision
2025-07-14
FDA-cleared K212383

EndoNaut

Therenva SAS

EndoNaut overlays preoperative three-dimensional vascular anatomy on live fluoroscopy and supports semi-automatic registration and motion detection for selected aneurysm, angioplasty, stenting, and embolization procedures.

Modality
Fluoroscopy/Angiography
Anatomy
Multi-region
Decision
2021-08-31

Correct this exact record

Copy this public context and add the field, proposed wording and original source before sending. Nothing here is submitted automatically. Form-specific prefill has not been verified.

Open existing correction destination

Permission to display a submission is not evidence verification. A submission enters editorial review; it does not approve a public change. Form availability, data entry, receipt, review and publication are separate steps. Data entry and receipt remain unverified.

Accepted repository change history

No entry has been added to this scoped change history for this record. This is not proof that the record never changed.

Correction policy and limits · Public repository change history